<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0" xmlns:media="http://search.yahoo.com/mrss/" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:itunes="http://www.itunes.com/dtds/podcast-1.0.dtd">
    <channel>
        <itunes:owner>
            <itunes:name>YSI Videos | ysi.com</itunes:name>
            <itunes:email>info@ysi.com</itunes:email>
        </itunes:owner>
        <title>Support | Tutorials | How-To</title>
        <link>https://video.ysi.com</link>
        <description>Product support. Tutorials on product usage and simple how-to videos.</description>
        <language>en-us</language>
        <generator>Visualplatform</generator>
        <docs>http://blogs.law.harvard.edu/tech/rss</docs>
        <itunes:author>YSI Videos | ysi.com</itunes:author>
        <itunes:summary>Product support. Tutorials on product usage and simple how-to videos.</itunes:summary>
        <itunes:type>episodic</itunes:type>
        <itunes:explicit>no</itunes:explicit>
        <itunes:image href="https://video.ysi.com/files/rv1.4/sitelogo.gif"/>
        <image>
            <url>https://video.ysi.com/files/rv1.4/sitelogo.gif</url>
            <title>Support | Tutorials | How-To</title>
            <link>https://video.ysi.com</link>
        </image>
        <atom:link rel="self" href="https://video.ysi.com/audiopodcast/support-tutorials-how-to"/>
        <atom:link rel="next" href="https://video.ysi.com/audiopodcast/support-tutorials-how-to?p=2&amp;album%5fid=19522241&amp;podcast%5fp=t&amp;https="/>
        <item>
            <enclosure url="http://video.ysi.com/64968578/113297613/13bd3e5d470a1624f4986a549a78c783/audio/podcast/113297613-62-audio.mp3" type="audio/mp3" length="5767661"/>
            <title>EXO Sonde Ordering Guide</title>
            <link>http://video.ysi.com/exo-sonde-ordering-guide</link>
            <description>&lt;p&gt;&lt;p&gt;This video explains the steps and considerations involved in purchasing a YSI EXO multiparameter water quality sonde.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;Need help selecting which sonde is best for your application? Take our short survey to find out:&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/water-quality-sonde-selector"&gt;EXO Sonde Selector&lt;/a&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/exo-sonde-ordering-guide"&gt;&lt;img src="http://video.ysi.com/64968578/113297613/13bd3e5d470a1624f4986a549a78c783/standard/download-62-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/113297613</guid>
            <pubDate>Tue, 26 Aug 2025 14:35:04 GMT</pubDate>
            <media:title>EXO Sonde Ordering Guide</media:title>
            <itunes:summary>This video explains the steps and considerations involved in purchasing a YSI EXO multiparameter water quality sonde.Need help selecting which sonde is best for your application? Take our short survey to find out:EXO Sonde Selector</itunes:summary>
            <itunes:subtitle>This video explains the steps and considerations involved in purchasing a YSI EXO multiparameter water quality sonde.Need help selecting which sonde is best for your application? Take our short survey to find out:EXO Sonde Selector</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>08:01</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;This video explains the steps and considerations involved in purchasing a YSI EXO multiparameter water quality sonde.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;Need help selecting which sonde is best for your application? Take our short survey to find out:&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/water-quality-sonde-selector"&gt;EXO Sonde Selector&lt;/a&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/exo-sonde-ordering-guide"&gt;&lt;img src="http://video.ysi.com/64968578/113297613/13bd3e5d470a1624f4986a549a78c783/standard/download-62-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=13bd3e5d470a1624f4986a549a78c783&amp;source=podcast&amp;photo%5fid=113297613" width="625" height="352" type="text/html" medium="video" duration="481" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968578/113297613/13bd3e5d470a1624f4986a549a78c783/standard/download-62-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968578/113297613/13bd3e5d470a1624f4986a549a78c783/standard/download-62-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968580/108587579/a43e31941dd942a014ff2c15852f46ec/audio/podcast/108587579-29-audio.mp3" type="audio/mp3" length="3051449"/>
            <title>YSI Alyza IQ | How to Clean the FM-PC Filter</title>
            <link>http://video.ysi.com/ysi-alyza-iq-how-to-clean-the</link>
            <description>&lt;p&gt;&lt;p&gt;In this video, learn how to properly clean the FM/PC filter for the Alyza IQ analyzer.&amp;nbsp;&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-alyza-iq-how-to-clean-the"&gt;&lt;img src="http://video.ysi.com/64968580/108587579/a43e31941dd942a014ff2c15852f46ec/standard/download-29-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/108587579</guid>
            <pubDate>Tue, 07 Jan 2025 11:12:27 GMT</pubDate>
            <media:title>YSI Alyza IQ | How to Clean the FM-PC Filter</media:title>
            <itunes:summary>In this video, learn how to properly clean the FM/PC filter for the Alyza IQ analyzer.
</itunes:summary>
            <itunes:subtitle>In this video, learn how to properly clean the FM/PC filter for the Alyza IQ analyzer.
</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>04:14</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;In this video, learn how to properly clean the FM/PC filter for the Alyza IQ analyzer.&amp;nbsp;&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-alyza-iq-how-to-clean-the"&gt;&lt;img src="http://video.ysi.com/64968580/108587579/a43e31941dd942a014ff2c15852f46ec/standard/download-29-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=a43e31941dd942a014ff2c15852f46ec&amp;source=podcast&amp;photo%5fid=108587579" width="625" height="352" type="text/html" medium="video" duration="254" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968580/108587579/a43e31941dd942a014ff2c15852f46ec/standard/download-29-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968580/108587579/a43e31941dd942a014ff2c15852f46ec/standard/download-29-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968577/108587507/6aad3e569413deffab2ffbc264eb4876/audio/podcast/108587507-25-audio.mp3" type="audio/mp3" length="4127276"/>
            <title>YSI Alyza IQ | Installing the Heated Lines</title>
            <link>http://video.ysi.com/ysi-alyza-iq-installing-the-heated</link>
            <description>&lt;p&gt;&lt;p&gt;In this video, learn how to install heated lines on the Alyza IQ analyzer.&amp;nbsp;&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-alyza-iq-installing-the-heated"&gt;&lt;img src="http://video.ysi.com/64968577/108587507/6aad3e569413deffab2ffbc264eb4876/standard/download-25-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/108587507</guid>
            <pubDate>Tue, 07 Jan 2025 11:10:41 GMT</pubDate>
            <media:title>YSI Alyza IQ | Installing the Heated Lines</media:title>
            <itunes:summary>In this video, learn how to install heated lines on the Alyza IQ analyzer.
</itunes:summary>
            <itunes:subtitle>In this video, learn how to install heated lines on the Alyza IQ analyzer.
</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>05:44</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;In this video, learn how to install heated lines on the Alyza IQ analyzer.&amp;nbsp;&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-alyza-iq-installing-the-heated"&gt;&lt;img src="http://video.ysi.com/64968577/108587507/6aad3e569413deffab2ffbc264eb4876/standard/download-25-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=6aad3e569413deffab2ffbc264eb4876&amp;source=podcast&amp;photo%5fid=108587507" width="625" height="352" type="text/html" medium="video" duration="344" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968577/108587507/6aad3e569413deffab2ffbc264eb4876/standard/download-25-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968577/108587507/6aad3e569413deffab2ffbc264eb4876/standard/download-25-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968567/108587266/12b2284adb3935862011ca30eeba6a73/audio/podcast/108587266-34-audio.mp3" type="audio/mp3" length="3845780"/>
            <title>YSI Alyza IQ | Replacing Consumables</title>
            <link>http://video.ysi.com/ysi-alyza-iq-replacing-consumables</link>
            <description>&lt;p&gt;&lt;p&gt;In this video, learn how to replace consumables on the Alyza IQ analyzer.&amp;nbsp;&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-alyza-iq-replacing-consumables"&gt;&lt;img src="http://video.ysi.com/64968567/108587266/12b2284adb3935862011ca30eeba6a73/standard/download-34-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/108587266</guid>
            <pubDate>Tue, 07 Jan 2025 10:54:02 GMT</pubDate>
            <media:title>YSI Alyza IQ | Replacing Consumables</media:title>
            <itunes:summary>In this video, learn how to replace consumables on the Alyza IQ analyzer.
</itunes:summary>
            <itunes:subtitle>In this video, learn how to replace consumables on the Alyza IQ analyzer.
</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>05:20</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;In this video, learn how to replace consumables on the Alyza IQ analyzer.&amp;nbsp;&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-alyza-iq-replacing-consumables"&gt;&lt;img src="http://video.ysi.com/64968567/108587266/12b2284adb3935862011ca30eeba6a73/standard/download-34-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=12b2284adb3935862011ca30eeba6a73&amp;source=podcast&amp;photo%5fid=108587266" width="625" height="352" type="text/html" medium="video" duration="320" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968567/108587266/12b2284adb3935862011ca30eeba6a73/standard/download-34-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968567/108587266/12b2284adb3935862011ca30eeba6a73/standard/download-34-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968578/107224440/5db502112136c84dbb61cd7fd25fbceb/audio/podcast/107224440-8-audio.mp3" type="audio/mp3" length="1140539"/>
            <title>Cómo reemplazar una membrana de tapa de oxígeno disuelto YSI</title>
            <link>http://video.ysi.com/como-reemplazar-una-membrana-de</link>
            <description>&lt;p&gt;&lt;p&gt;En este video, les ensenaremos como instalar una membrana nueva con solución electrolítica en su sensor de oxigeno disuelto Pro Series.&amp;nbsp;&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/como-reemplazar-una-membrana-de"&gt;&lt;img src="http://video.ysi.com/64968578/107224440/5db502112136c84dbb61cd7fd25fbceb/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/107224440</guid>
            <pubDate>Wed, 04 Dec 2024 10:15:04 GMT</pubDate>
            <media:title>Cómo reemplazar una membrana de tapa de oxígeno disuelto YSI</media:title>
            <itunes:summary>En este video, les ensenaremos como instalar una membrana nueva con solución electrolítica en su sensor de oxigeno disuelto Pro Series.
</itunes:summary>
            <itunes:subtitle>En este video, les ensenaremos como instalar una membrana nueva con solución electrolítica en su sensor de oxigeno disuelto Pro Series.
</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:35</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;En este video, les ensenaremos como instalar una membrana nueva con solución electrolítica en su sensor de oxigeno disuelto Pro Series.&amp;nbsp;&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/como-reemplazar-una-membrana-de"&gt;&lt;img src="http://video.ysi.com/64968578/107224440/5db502112136c84dbb61cd7fd25fbceb/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=5db502112136c84dbb61cd7fd25fbceb&amp;source=podcast&amp;photo%5fid=107224440" width="625" height="352" type="text/html" medium="video" duration="95" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968578/107224440/5db502112136c84dbb61cd7fd25fbceb/standard/download-8-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968578/107224440/5db502112136c84dbb61cd7fd25fbceb/standard/download-8-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968569/107224340/e713086979727e0b70e66071d196dc83/audio/podcast/107224340-11-audio.mp3" type="audio/mp3" length="908572"/>
            <title> Cómo calibrar el medidor de oxígeno disuelto YSI Pro20</title>
            <link>http://video.ysi.com/como-calibrar-el-medidor-de-oxigeno</link>
            <description>&lt;p&gt;&lt;p&gt;En este video, cubriremos la función Calibración de un Solo Toque en el instrumento Pro20, medidor de oxígeno disuelto de mano.&amp;nbsp;&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/como-calibrar-el-medidor-de-oxigeno"&gt;&lt;img src="http://video.ysi.com/64968569/107224340/e713086979727e0b70e66071d196dc83/standard/download-11-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/107224340</guid>
            <pubDate>Wed, 04 Dec 2024 10:13:38 GMT</pubDate>
            <media:title> Cómo calibrar el medidor de oxígeno disuelto YSI Pro20</media:title>
            <itunes:summary>En este video, cubriremos la función Calibración de un Solo Toque en el instrumento Pro20, medidor de oxígeno disuelto de mano.
</itunes:summary>
            <itunes:subtitle>En este video, cubriremos la función Calibración de un Solo Toque en el instrumento Pro20, medidor de oxígeno disuelto de mano.
</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:16</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;En este video, cubriremos la función Calibración de un Solo Toque en el instrumento Pro20, medidor de oxígeno disuelto de mano.&amp;nbsp;&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/como-calibrar-el-medidor-de-oxigeno"&gt;&lt;img src="http://video.ysi.com/64968569/107224340/e713086979727e0b70e66071d196dc83/standard/download-11-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=e713086979727e0b70e66071d196dc83&amp;source=podcast&amp;photo%5fid=107224340" width="625" height="352" type="text/html" medium="video" duration="76" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968569/107224340/e713086979727e0b70e66071d196dc83/standard/download-11-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968569/107224340/e713086979727e0b70e66071d196dc83/standard/download-11-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968561/107224306/1988a6fcf70f6ce1efb508e9444145ab/audio/podcast/107224306-96-audio.mp3" type="audio/mp3" length="847132"/>
            <title>How to Calibrate the YSI Pro20 Dissolved Oxygen Meter</title>
            <link>http://video.ysi.com/how-to-calibrate-the-ysi-pro20</link>
            <description>&lt;p&gt;&lt;p&gt;In this video we’ll cover the One-Touch Calibration feature for the Pro20 Dissolved Oxygen meter.  &amp;nbsp;&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-calibrate-the-ysi-pro20"&gt;&lt;img src="http://video.ysi.com/64968561/107224306/1988a6fcf70f6ce1efb508e9444145ab/standard/download-96-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/107224306</guid>
            <pubDate>Wed, 04 Dec 2024 10:11:21 GMT</pubDate>
            <media:title>How to Calibrate the YSI Pro20 Dissolved Oxygen Meter</media:title>
            <itunes:summary>In this video we’ll cover the One-Touch Calibration feature for the Pro20 Dissolved Oxygen meter.  
</itunes:summary>
            <itunes:subtitle>In this video we’ll cover the One-Touch Calibration feature for the Pro20 Dissolved Oxygen meter.  
</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:11</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;In this video we’ll cover the One-Touch Calibration feature for the Pro20 Dissolved Oxygen meter.  &amp;nbsp;&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-calibrate-the-ysi-pro20"&gt;&lt;img src="http://video.ysi.com/64968561/107224306/1988a6fcf70f6ce1efb508e9444145ab/standard/download-96-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=1988a6fcf70f6ce1efb508e9444145ab&amp;source=podcast&amp;photo%5fid=107224306" width="625" height="352" type="text/html" medium="video" duration="71" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968561/107224306/1988a6fcf70f6ce1efb508e9444145ab/standard/download-96-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968561/107224306/1988a6fcf70f6ce1efb508e9444145ab/standard/download-96-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968577/107224259/7fb5d0c07d27a171dd4aeff41ab937c4/audio/podcast/107224259-34-audio.mp3" type="audio/mp3" length="1043364"/>
            <title>How to Replace a YSI Dissolved Oxygen Cap Membrane</title>
            <link>http://video.ysi.com/how-to-replace-a-ysi-dissolved</link>
            <description>&lt;p&gt;&lt;p&gt;In this video, we’ll show you how to install a membrane covered dissolved oxygen cap on your Pro Series DO sensor.&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-replace-a-ysi-dissolved"&gt;&lt;img src="http://video.ysi.com/64968577/107224259/7fb5d0c07d27a171dd4aeff41ab937c4/standard/download-34-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/107224259</guid>
            <pubDate>Wed, 04 Dec 2024 10:02:11 GMT</pubDate>
            <media:title>How to Replace a YSI Dissolved Oxygen Cap Membrane</media:title>
            <itunes:summary>In this video, we’ll show you how to install a membrane covered dissolved oxygen cap on your Pro Series DO sensor.
</itunes:summary>
            <itunes:subtitle>In this video, we’ll show you how to install a membrane covered dissolved oxygen cap on your Pro Series DO sensor.
</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:27</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;In this video, we’ll show you how to install a membrane covered dissolved oxygen cap on your Pro Series DO sensor.&lt;/p&gt;
&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-replace-a-ysi-dissolved"&gt;&lt;img src="http://video.ysi.com/64968577/107224259/7fb5d0c07d27a171dd4aeff41ab937c4/standard/download-34-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=7fb5d0c07d27a171dd4aeff41ab937c4&amp;source=podcast&amp;photo%5fid=107224259" width="625" height="352" type="text/html" medium="video" duration="87" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968577/107224259/7fb5d0c07d27a171dd4aeff41ab937c4/standard/download-34-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968577/107224259/7fb5d0c07d27a171dd4aeff41ab937c4/standard/download-34-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968568/89654825/906b25aa63ba4712549efce047660e23/audio/podcast/89654825-30-audio.mp3" type="audio/mp3" length="1852428"/>
            <title>Turb 750 T Operation | Benchtop Turbidimeter</title>
            <link>http://video.ysi.com/turb-750-t-operation-benchtop</link>
            <description>&lt;p&gt;&lt;p&gt;See how easy it is to&amp;nbsp;set up, calibrate,
and run samples on the YSI Turb 750 T, our benchtop turbidimeter. The entire
process only takes a few minutes, thanks to its straightforward design.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/turb-750-t-operation-benchtop"&gt;&lt;img src="http://video.ysi.com/64968568/89654825/906b25aa63ba4712549efce047660e23/standard/download-30-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/89654825</guid>
            <pubDate>Tue, 17 Oct 2023 08:18:06 GMT</pubDate>
            <media:title>Turb 750 T Operation | Benchtop Turbidimeter</media:title>
            <itunes:summary>See how easy it is toset up, calibrate,
and run samples on the YSI Turb 750 T, our benchtop turbidimeter. The entire
process only takes a few minutes, thanks to its straightforward design.</itunes:summary>
            <itunes:subtitle>See how easy it is toset up, calibrate,
and run samples on the YSI Turb 750 T, our benchtop turbidimeter. The entire
process only takes a few minutes, thanks to its straightforward design.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>02:34</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;See how easy it is to&amp;nbsp;set up, calibrate,
and run samples on the YSI Turb 750 T, our benchtop turbidimeter. The entire
process only takes a few minutes, thanks to its straightforward design.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/turb-750-t-operation-benchtop"&gt;&lt;img src="http://video.ysi.com/64968568/89654825/906b25aa63ba4712549efce047660e23/standard/download-30-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=906b25aa63ba4712549efce047660e23&amp;source=podcast&amp;photo%5fid=89654825" width="625" height="352" type="text/html" medium="video" duration="154" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968568/89654825/906b25aa63ba4712549efce047660e23/standard/download-30-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968568/89654825/906b25aa63ba4712549efce047660e23/standard/download-30-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968560/87175082/071ffe6e89d5a70e9efb1264c32fa37a/audio/podcast/87175082-8-audio.mp3" type="audio/mp3" length="43656079"/>
            <title>Webinar | Effective Strategies for Online Sensor Maintenance - Part 4</title>
            <link>http://video.ysi.com/webinar-effective-strategies-for</link>
            <description>&lt;p&gt;&lt;p&gt;&lt;strong&gt;Managing Data and Implementing Preventative Maintenance Programs&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Part four of our new webinar series, &lt;strong&gt;&lt;em&gt;How to Get Optimal Data with Online Instrumentation&lt;/em&gt;&lt;/strong&gt;. In this four-part series, we review best practices for maintaining online sensors and analyzers, effectively managing data, and establishing a standard operating procedure for maintenance.&lt;/p&gt;&lt;p&gt;Understanding the maintenance requirements for online analytical instrumentation is crucial, but it's only one aspect of the equation. The other half involves performing and effectively tracking equipment maintenance. To ensure optimal performance and proactively prevent issues within water treatment plants, it is crucial to establish and execute a sound strategy for equipment maintenance. This webinar will provide guidance on setting up, implementing, and documenting preventative maintenance programs to ensure accurate and reliable data from your instrumentation.&lt;/p&gt;&lt;p&gt;&lt;strong&gt;In part four&lt;/strong&gt;, learn how to create, implement, and execute preventative maintenance programs for online analytical instrumentation. We'll discuss the basic philosophy behind preventative maintenance programs as well as showcase live demonstrations of tools used to track maintenance activities. Join us as we introduce IQSN Mobile, a powerful solution for maintenance tracking, and learn how to minimize downtime and maximize instrument performance through effective maintenance practices.&lt;/p&gt;&lt;p&gt;&lt;strong&gt;You'll learn the following:&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;The basic philosophy behind preventative maintenance programs.&lt;br&gt;Pro tips on creating, implementing, and executing maintenance programs that minimize downtime and optimize performance.&lt;br&gt;Digital assets that simplify and streamline instrument maintenance.&lt;br&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Who should attend:&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Water treatment engineers, operators, instrument technicians, and superintendents who want to learn more about online instrumentation and sensor applications.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Earn CEUs!&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;This live educational webinar will be 50 minutes with 10 minutes for Q&amp;amp;A. After the webinar, attendees are eligible to receive a certificate awarding 0.1 CEUs (1 PDH).&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;On-Demand - Best Practices for Online Sensor Maintenance Part I, II, III&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/how-to-get-optimal-data-with-online-instrumentation-best-practices-for-online-sensor-maintenance"&gt;https://www.ysi.com/webinars/how-to-get-optimal-data-with-online-instrumentation-best-practices-for-online-sensor-maintenance&lt;/a&gt; Watch part one of the series, which covers maintenance procedures and best practices for YSI IQ SensorNet &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/fdo"&gt;FDO&lt;/a&gt; (dissolved oxygen), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/sensolyt"&gt;SensoLyt&lt;/a&gt; (pH/ORP), and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/varion"&gt;VARiON ISE&lt;/a&gt; (ammonium/nitrate) sensors.&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/best-practices-for-online-sensor-maintenance-part-2"&gt;Watch part two of the series&lt;/a&gt;, which covers the &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visolid"&gt;ViSolid&lt;/a&gt; (TSS), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visoturb"&gt;VisoTurb&lt;/a&gt; (turbidity), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/file%20library/documents/guides/uv-uv-vis-sensor-application-guide.pdf"&gt;UV-Vis&lt;/a&gt; (nitrate, COD, BOD, etc.), and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/ifl"&gt;IFL&lt;/a&gt; (sludge level) sensors.&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/best-practices-for-online-sensor-maintenance-part-3"&gt;Watch part three of the series&lt;/a&gt;, which covers the Alyza IQ Platform (&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/po4"&gt;Orthophosphate&lt;/a&gt; and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/nh4"&gt;Ammonium&lt;/a&gt;) and the &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/3017m"&gt;3017M&lt;/a&gt; (chlorine) analyzers.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/webinar-effective-strategies-for"&gt;&lt;img src="http://video.ysi.com/64968560/87175082/071ffe6e89d5a70e9efb1264c32fa37a/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/87175082</guid>
            <pubDate>Tue, 25 Jul 2023 08:25:21 GMT</pubDate>
            <media:title>Webinar | Effective Strategies for Online Sensor Maintenance - Part 4</media:title>
            <itunes:summary>Managing Data and Implementing Preventative Maintenance ProgramsPart four of our new webinar series, How to Get Optimal Data with Online Instrumentation. In this four-part series, we review best practices for maintaining online sensors and analyzers, effectively managing data, and establishing a standard operating procedure for maintenance.Understanding the maintenance requirements for online analytical instrumentation is crucial, but it's only one aspect of the equation. The other half involves performing and effectively tracking equipment maintenance. To ensure optimal performance and proactively prevent issues within water treatment plants, it is crucial to establish and execute a sound strategy for equipment maintenance. This webinar will provide guidance on setting up, implementing, and documenting preventative maintenance programs to ensure accurate and reliable data from your instrumentation.In part four, learn how to create, implement, and execute preventative maintenance programs for online analytical instrumentation. We'll discuss the basic philosophy behind preventative maintenance programs as well as showcase live demonstrations of tools used to track maintenance activities. Join us as we introduce IQSN Mobile, a powerful solution for maintenance tracking, and learn how to minimize downtime and maximize instrument performance through effective maintenance practices.You'll learn the following:The basic philosophy behind preventative maintenance programs.Pro tips on creating, implementing, and executing maintenance programs that minimize downtime and optimize performance.Digital assets that simplify and streamline instrument maintenance.Who should attend:Water treatment engineers, operators, instrument technicians, and superintendents who want to learn more about online instrumentation and sensor applications.Earn CEUs!This live educational webinar will be 50 minutes with 10 minutes for QA. After the webinar, attendees are eligible to receive a certificate awarding 0.1 CEUs (1 PDH).On-Demand - Best Practices for Online Sensor Maintenance Part I, II, IIIhttps://www.ysi.com/webinars/how-to-get-optimal-data-with-online-instrumentation-best-practices-for-online-sensor-maintenance Watch part one of the series, which covers maintenance procedures and best practices for YSI IQ SensorNet FDO (dissolved oxygen), SensoLyt (pH/ORP), and VARiON ISE (ammonium/nitrate) sensors.Watch part two of the series, which covers the ViSolid (TSS), VisoTurb (turbidity), UV-Vis (nitrate, COD, BOD, etc.), and IFL (sludge level) sensors.Watch part three of the series, which covers the Alyza IQ Platform (Orthophosphate and Ammonium) and the 3017M (chlorine) analyzers.</itunes:summary>
            <itunes:subtitle>Managing Data and Implementing Preventative Maintenance ProgramsPart four of our new webinar series, How to Get Optimal Data with Online Instrumentation. In this four-part series, we review best practices for maintaining online sensors and...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:00:38</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;&lt;strong&gt;Managing Data and Implementing Preventative Maintenance Programs&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Part four of our new webinar series, &lt;strong&gt;&lt;em&gt;How to Get Optimal Data with Online Instrumentation&lt;/em&gt;&lt;/strong&gt;. In this four-part series, we review best practices for maintaining online sensors and analyzers, effectively managing data, and establishing a standard operating procedure for maintenance.&lt;/p&gt;&lt;p&gt;Understanding the maintenance requirements for online analytical instrumentation is crucial, but it's only one aspect of the equation. The other half involves performing and effectively tracking equipment maintenance. To ensure optimal performance and proactively prevent issues within water treatment plants, it is crucial to establish and execute a sound strategy for equipment maintenance. This webinar will provide guidance on setting up, implementing, and documenting preventative maintenance programs to ensure accurate and reliable data from your instrumentation.&lt;/p&gt;&lt;p&gt;&lt;strong&gt;In part four&lt;/strong&gt;, learn how to create, implement, and execute preventative maintenance programs for online analytical instrumentation. We'll discuss the basic philosophy behind preventative maintenance programs as well as showcase live demonstrations of tools used to track maintenance activities. Join us as we introduce IQSN Mobile, a powerful solution for maintenance tracking, and learn how to minimize downtime and maximize instrument performance through effective maintenance practices.&lt;/p&gt;&lt;p&gt;&lt;strong&gt;You'll learn the following:&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;The basic philosophy behind preventative maintenance programs.&lt;br&gt;Pro tips on creating, implementing, and executing maintenance programs that minimize downtime and optimize performance.&lt;br&gt;Digital assets that simplify and streamline instrument maintenance.&lt;br&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Who should attend:&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Water treatment engineers, operators, instrument technicians, and superintendents who want to learn more about online instrumentation and sensor applications.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Earn CEUs!&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;This live educational webinar will be 50 minutes with 10 minutes for Q&amp;amp;A. After the webinar, attendees are eligible to receive a certificate awarding 0.1 CEUs (1 PDH).&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;On-Demand - Best Practices for Online Sensor Maintenance Part I, II, III&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/how-to-get-optimal-data-with-online-instrumentation-best-practices-for-online-sensor-maintenance"&gt;https://www.ysi.com/webinars/how-to-get-optimal-data-with-online-instrumentation-best-practices-for-online-sensor-maintenance&lt;/a&gt; Watch part one of the series, which covers maintenance procedures and best practices for YSI IQ SensorNet &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/fdo"&gt;FDO&lt;/a&gt; (dissolved oxygen), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/sensolyt"&gt;SensoLyt&lt;/a&gt; (pH/ORP), and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/varion"&gt;VARiON ISE&lt;/a&gt; (ammonium/nitrate) sensors.&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/best-practices-for-online-sensor-maintenance-part-2"&gt;Watch part two of the series&lt;/a&gt;, which covers the &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visolid"&gt;ViSolid&lt;/a&gt; (TSS), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visoturb"&gt;VisoTurb&lt;/a&gt; (turbidity), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/file%20library/documents/guides/uv-uv-vis-sensor-application-guide.pdf"&gt;UV-Vis&lt;/a&gt; (nitrate, COD, BOD, etc.), and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/ifl"&gt;IFL&lt;/a&gt; (sludge level) sensors.&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/best-practices-for-online-sensor-maintenance-part-3"&gt;Watch part three of the series&lt;/a&gt;, which covers the Alyza IQ Platform (&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/po4"&gt;Orthophosphate&lt;/a&gt; and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/nh4"&gt;Ammonium&lt;/a&gt;) and the &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/3017m"&gt;3017M&lt;/a&gt; (chlorine) analyzers.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/webinar-effective-strategies-for"&gt;&lt;img src="http://video.ysi.com/64968560/87175082/071ffe6e89d5a70e9efb1264c32fa37a/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=071ffe6e89d5a70e9efb1264c32fa37a&amp;source=podcast&amp;photo%5fid=87175082" width="625" height="391" type="text/html" medium="video" duration="3638" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968560/87175082/071ffe6e89d5a70e9efb1264c32fa37a/standard/download-8-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968560/87175082/071ffe6e89d5a70e9efb1264c32fa37a/standard/download-8-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
            <category>maintenance</category>
            <category>wastewater</category>
            <category>wastewater process monitoring</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968569/85721694/e98eb6ad4f14bd96525bd75d1f574635/audio/podcast/85721694-8-audio.mp3" type="audio/mp3" length="43093088"/>
            <title>Webinar | Best Practices for Online Analyzer Maintenance - Part 3</title>
            <link>http://video.ysi.com/webinar-best-practices-for-online-1</link>
            <description>&lt;p&gt;&lt;p&gt;Part three of our new webinar series, &lt;strong&gt;&lt;em&gt;How to Get Optimal Data with Online Instrumentation&lt;/em&gt;&lt;/strong&gt;.&amp;nbsp;&lt;/p&gt;&lt;p&gt;Analyzer maintenance can be divided into cleaning, calibration, and consumables. Maintenance processes can sometimes be automated, making analyzer maintenance easier. However, wet chemistry analyzers are generally more complicated than in situ sensors, and each analyzer has its own set of requirements to ensure that it operates as intended. In this webinar, we'll dive into online wet chemistry analyzers, explaining where in the process to use them and how to keep them running smoothly.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;In part three&lt;/strong&gt;, learn the basics of online analyzers and when and where it's appropriate to deploy these instruments instead of in situ sensors. We'll showcase live demonstrations of required maintenance procedures and best practices to keep online analyzers functioning properly. Join us to learn more about Alyza IQ analyzers (orthophosphate/ammonium) and YSI's 3017M (chlorine).&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;You’ll learn the following:&lt;/strong&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;&lt;p&gt;Which applications are best suited for online wet chemistry analyzers.&lt;/p&gt;&lt;/li&gt;&lt;li&gt;&lt;p&gt;Best practices for maintaining analyzers and what's required for successful commissioning and operation.&lt;/p&gt;&lt;/li&gt;&lt;li&gt;&lt;p&gt;How to perform the basic operation, startup, and servicing for each analyzer to ensure accurate and reliable data collection.&lt;/p&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Who should watch:&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Water treatment engineers, operators, instrument technicians, and superintendents who want to learn more about online instrumentation and sensor applications.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Earn CEUs!&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;This live educational webinar will be 50 minutes with 10 minutes for Q&amp;amp;A. After the webinar, attendees are eligible to receive a certificate awarding 0.1 CEUs (1 PDH).&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;On-Demand - Best Practices for Online Sensor Maintenance Parts 1 &amp;amp; 2&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/how-to-get-optimal-data-with-online-instrumentation-best-practices-for-online-sensor-maintenance"&gt;Watch part one of the series&lt;/a&gt;, which covers maintenance procedures and best practices for YSI IQ SensorNet &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/fdo"&gt;FDO&lt;/a&gt; (dissolved oxygen), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/sensolyt"&gt;SensoLyt&lt;/a&gt; (pH/ORP), and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/varion"&gt;VARiON ISE&lt;/a&gt; (ammonium/nitrate) sensors.&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/best-practices-for-online-sensor-maintenance-part-2"&gt;Watch part two of the series&lt;/a&gt;, which covers the &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visolid"&gt;ViSolid&lt;/a&gt; (TSS), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visoturb"&gt;VisoTurb&lt;/a&gt; (turbidity), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/file%20library/documents/guides/uv-uv-vis-sensor-application-guide.pdf"&gt;UV-Vis&lt;/a&gt; (nitrate, COD, BOD, etc.), and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/ifl"&gt;IFL&lt;/a&gt; (sludge level) sensors.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/webinar-best-practices-for-online-1"&gt;&lt;img src="http://video.ysi.com/64968569/85721694/e98eb6ad4f14bd96525bd75d1f574635/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/85721694</guid>
            <pubDate>Fri, 05 May 2023 14:26:40 GMT</pubDate>
            <media:title>Webinar | Best Practices for Online Analyzer Maintenance - Part 3</media:title>
            <itunes:summary>Part three of our new webinar series, How to Get Optimal Data with Online Instrumentation.Analyzer maintenance can be divided into cleaning, calibration, and consumables. Maintenance processes can sometimes be automated, making analyzer maintenance easier. However, wet chemistry analyzers are generally more complicated than in situ sensors, and each analyzer has its own set of requirements to ensure that it operates as intended. In this webinar, we'll dive into online wet chemistry analyzers, explaining where in the process to use them and how to keep them running smoothly.In part three, learn the basics of online analyzers and when and where it's appropriate to deploy these instruments instead of in situ sensors. We'll showcase live demonstrations of required maintenance procedures and best practices to keep online analyzers functioning properly. Join us to learn more about Alyza IQ analyzers (orthophosphate/ammonium) and YSI's 3017M (chlorine).You’ll learn the following:Which applications are best suited for online wet chemistry analyzers.Best practices for maintaining analyzers and what's required for successful commissioning and operation.How to perform the basic operation, startup, and servicing for each analyzer to ensure accurate and reliable data collection.Who should watch:Water treatment engineers, operators, instrument technicians, and superintendents who want to learn more about online instrumentation and sensor applications.Earn CEUs!This live educational webinar will be 50 minutes with 10 minutes for QA. After the webinar, attendees are eligible to receive a certificate awarding 0.1 CEUs (1 PDH).On-Demand - Best Practices for Online Sensor Maintenance Parts 1  2Watch part one of the series, which covers maintenance procedures and best practices for YSI IQ SensorNet FDO (dissolved oxygen), SensoLyt (pH/ORP), and VARiON ISE (ammonium/nitrate) sensors.Watch part two of the series, which covers the ViSolid (TSS), VisoTurb (turbidity), UV-Vis (nitrate, COD, BOD, etc.), and IFL (sludge level) sensors.</itunes:summary>
            <itunes:subtitle>Part three of our new webinar series, How to Get Optimal Data with Online Instrumentation.Analyzer maintenance can be divided into cleaning, calibration, and consumables. Maintenance processes can sometimes be automated, making analyzer...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>59:51</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;Part three of our new webinar series, &lt;strong&gt;&lt;em&gt;How to Get Optimal Data with Online Instrumentation&lt;/em&gt;&lt;/strong&gt;.&amp;nbsp;&lt;/p&gt;&lt;p&gt;Analyzer maintenance can be divided into cleaning, calibration, and consumables. Maintenance processes can sometimes be automated, making analyzer maintenance easier. However, wet chemistry analyzers are generally more complicated than in situ sensors, and each analyzer has its own set of requirements to ensure that it operates as intended. In this webinar, we'll dive into online wet chemistry analyzers, explaining where in the process to use them and how to keep them running smoothly.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;In part three&lt;/strong&gt;, learn the basics of online analyzers and when and where it's appropriate to deploy these instruments instead of in situ sensors. We'll showcase live demonstrations of required maintenance procedures and best practices to keep online analyzers functioning properly. Join us to learn more about Alyza IQ analyzers (orthophosphate/ammonium) and YSI's 3017M (chlorine).&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;You’ll learn the following:&lt;/strong&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;&lt;p&gt;Which applications are best suited for online wet chemistry analyzers.&lt;/p&gt;&lt;/li&gt;&lt;li&gt;&lt;p&gt;Best practices for maintaining analyzers and what's required for successful commissioning and operation.&lt;/p&gt;&lt;/li&gt;&lt;li&gt;&lt;p&gt;How to perform the basic operation, startup, and servicing for each analyzer to ensure accurate and reliable data collection.&lt;/p&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Who should watch:&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Water treatment engineers, operators, instrument technicians, and superintendents who want to learn more about online instrumentation and sensor applications.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Earn CEUs!&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;This live educational webinar will be 50 minutes with 10 minutes for Q&amp;amp;A. After the webinar, attendees are eligible to receive a certificate awarding 0.1 CEUs (1 PDH).&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;On-Demand - Best Practices for Online Sensor Maintenance Parts 1 &amp;amp; 2&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/how-to-get-optimal-data-with-online-instrumentation-best-practices-for-online-sensor-maintenance"&gt;Watch part one of the series&lt;/a&gt;, which covers maintenance procedures and best practices for YSI IQ SensorNet &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/fdo"&gt;FDO&lt;/a&gt; (dissolved oxygen), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/sensolyt"&gt;SensoLyt&lt;/a&gt; (pH/ORP), and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/varion"&gt;VARiON ISE&lt;/a&gt; (ammonium/nitrate) sensors.&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/best-practices-for-online-sensor-maintenance-part-2"&gt;Watch part two of the series&lt;/a&gt;, which covers the &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visolid"&gt;ViSolid&lt;/a&gt; (TSS), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visoturb"&gt;VisoTurb&lt;/a&gt; (turbidity), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/file%20library/documents/guides/uv-uv-vis-sensor-application-guide.pdf"&gt;UV-Vis&lt;/a&gt; (nitrate, COD, BOD, etc.), and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/ifl"&gt;IFL&lt;/a&gt; (sludge level) sensors.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/webinar-best-practices-for-online-1"&gt;&lt;img src="http://video.ysi.com/64968569/85721694/e98eb6ad4f14bd96525bd75d1f574635/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=e98eb6ad4f14bd96525bd75d1f574635&amp;source=podcast&amp;photo%5fid=85721694" width="625" height="391" type="text/html" medium="video" duration="3591" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968569/85721694/e98eb6ad4f14bd96525bd75d1f574635/standard/download-8-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968569/85721694/e98eb6ad4f14bd96525bd75d1f574635/standard/download-8-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
            <category>wastewater</category>
            <category>wastewater process monitoring</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968567/83733523/c0289bd24dbe8258e895dd0428fc7363/audio/podcast/83733523-8-audio.mp3" type="audio/mp3" length="33136987"/>
            <title>Webinar | Best Practices for Sensor Maintenance - Part 2</title>
            <link>http://video.ysi.com/webinar-best-practices-for-sensor</link>
            <description>&lt;p&gt;&lt;p&gt;Part two of our new webinar series,&amp;nbsp;&lt;strong&gt;&lt;em&gt;How to Get Optimal Data with Online Instrumentation.&amp;nbsp;&lt;/em&gt;&lt;/strong&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;Sensor maintenance can be divided into cleaning, calibration, and consumables. Of these, the most often misunderstood is calibration. Depending on the sensor, there are several types of calibrations, and often you can calibrate a sensor with multiple methods.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;In part two&lt;/strong&gt;, learn the basics of calibration and why it’s essential to ensure your sensors remain accurate. In addition, we’ll showcase live, hands-on demonstrations of maintenance procedures for YSI&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/iqsn"&gt;IQ SensorNet&lt;/a&gt;&amp;nbsp;online sensors and share best practices for maintaining each sensor type. In this webinar, we’ll cover the&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visolid"&gt;ViSolid&lt;/a&gt;&amp;nbsp;(TSS),&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visoturb"&gt;VisoTurb&lt;/a&gt;&amp;nbsp;(turbidity),&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/file%20library/documents/guides/uv-uv-vis-sensor-application-guide.pdf"&gt;UV-Vis&lt;/a&gt;&amp;nbsp;(nitrate, COD, BOD, etc.), and&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/ifl"&gt;IFL&lt;/a&gt;&amp;nbsp;(sludge level) sensors.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;You’ll learn the following:&lt;/strong&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;&lt;p&gt;How and why calibrations are essential to the operation of online sensors.&lt;/p&gt;&lt;/li&gt;&lt;li&gt;&lt;p&gt;Best practices for maintaining sensors and how to get the best data.&lt;/p&gt;&lt;/li&gt;&lt;li&gt;&lt;p&gt;How to perform the basic operation, setup, cleaning, calibration, and consumable parts required for YSI online instrumentation (TSS, turbidity, UV-Vis, and sludge level).&lt;/p&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Who should watch:&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Water treatment engineers, operators, instrument technicians, and superintendents who want to learn more about online instrumentation and sensor applications.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Earn CEUs!&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;This live educational webinar will be 50 minutes with 10 minutes for Q&amp;amp;A. After the webinar, attendees are eligible to receive a certificate awarding 0.1 CEUs (1 PDH).&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;On-Demand - Best Practices for Online Sensor Maintenance Parts 1 &amp;amp; 3&lt;/strong&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://video.ysi.com/webinar-best-practices-for-online"&gt;Watch part one of the series&lt;/a&gt;, which covers maintenance procedures and best practices for YSI IQ SensorNet&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/fdo"&gt;FDO&lt;/a&gt;&amp;nbsp;(dissolved oxygen),&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/sensolyt"&gt;SensoLyt&lt;/a&gt;&amp;nbsp;(pH/ORP), and&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/varion"&gt;VARiON ISE&lt;/a&gt;&amp;nbsp;(ammonium/nitrate) sensors.&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/best-practices-for-online-sensor-maintenance-part-3"&gt;Watch part three of the series&lt;/a&gt;, which covers &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://video.ysi.com/alyza-iq-overview"&gt;Alyza IQ&lt;/a&gt; (ammonium, orthophosphate) and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://video.ysi.com/ysi-3017m-chlorine-analyzer"&gt;3017M&lt;/a&gt; (chlorine) wet-chemistry analyzers.&amp;nbsp;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/webinar-best-practices-for-sensor"&gt;&lt;img src="http://video.ysi.com/64968567/83733523/c0289bd24dbe8258e895dd0428fc7363/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/83733523</guid>
            <pubDate>Wed, 01 Mar 2023 10:56:35 GMT</pubDate>
            <media:title>Webinar | Best Practices for Sensor Maintenance - Part 2</media:title>
            <itunes:summary>Part two of our new webinar series,How to Get Optimal Data with Online Instrumentation.Sensor maintenance can be divided into cleaning, calibration, and consumables. Of these, the most often misunderstood is calibration. Depending on the sensor, there are several types of calibrations, and often you can calibrate a sensor with multiple methods.In part two, learn the basics of calibration and why it’s essential to ensure your sensors remain accurate. In addition, we’ll showcase live, hands-on demonstrations of maintenance procedures for YSIIQ SensorNetonline sensors and share best practices for maintaining each sensor type. In this webinar, we’ll cover theViSolid(TSS),VisoTurb(turbidity),UV-Vis(nitrate, COD, BOD, etc.), andIFL(sludge level) sensors.You’ll learn the following:How and why calibrations are essential to the operation of online sensors.Best practices for maintaining sensors and how to get the best data.How to perform the basic operation, setup, cleaning, calibration, and consumable parts required for YSI online instrumentation (TSS, turbidity, UV-Vis, and sludge level).Who should watch:Water treatment engineers, operators, instrument technicians, and superintendents who want to learn more about online instrumentation and sensor applications.Earn CEUs!This live educational webinar will be 50 minutes with 10 minutes for QA. After the webinar, attendees are eligible to receive a certificate awarding 0.1 CEUs (1 PDH).On-Demand - Best Practices for Online Sensor Maintenance Parts 1  3Watch part one of the series, which covers maintenance procedures and best practices for YSI IQ SensorNetFDO(dissolved oxygen),SensoLyt(pH/ORP), andVARiON ISE(ammonium/nitrate) sensors.Watch part three of the series, which covers Alyza IQ (ammonium, orthophosphate) and 3017M (chlorine) wet-chemistry analyzers.</itunes:summary>
            <itunes:subtitle>Part two of our new webinar series,How to Get Optimal Data with Online Instrumentation.Sensor maintenance can be divided into cleaning, calibration, and consumables. Of these, the most often misunderstood is calibration. Depending on the sensor,...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>46:01</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;Part two of our new webinar series,&amp;nbsp;&lt;strong&gt;&lt;em&gt;How to Get Optimal Data with Online Instrumentation.&amp;nbsp;&lt;/em&gt;&lt;/strong&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;Sensor maintenance can be divided into cleaning, calibration, and consumables. Of these, the most often misunderstood is calibration. Depending on the sensor, there are several types of calibrations, and often you can calibrate a sensor with multiple methods.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;In part two&lt;/strong&gt;, learn the basics of calibration and why it’s essential to ensure your sensors remain accurate. In addition, we’ll showcase live, hands-on demonstrations of maintenance procedures for YSI&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/iqsn"&gt;IQ SensorNet&lt;/a&gt;&amp;nbsp;online sensors and share best practices for maintaining each sensor type. In this webinar, we’ll cover the&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visolid"&gt;ViSolid&lt;/a&gt;&amp;nbsp;(TSS),&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visoturb"&gt;VisoTurb&lt;/a&gt;&amp;nbsp;(turbidity),&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/file%20library/documents/guides/uv-uv-vis-sensor-application-guide.pdf"&gt;UV-Vis&lt;/a&gt;&amp;nbsp;(nitrate, COD, BOD, etc.), and&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/ifl"&gt;IFL&lt;/a&gt;&amp;nbsp;(sludge level) sensors.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;You’ll learn the following:&lt;/strong&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;&lt;p&gt;How and why calibrations are essential to the operation of online sensors.&lt;/p&gt;&lt;/li&gt;&lt;li&gt;&lt;p&gt;Best practices for maintaining sensors and how to get the best data.&lt;/p&gt;&lt;/li&gt;&lt;li&gt;&lt;p&gt;How to perform the basic operation, setup, cleaning, calibration, and consumable parts required for YSI online instrumentation (TSS, turbidity, UV-Vis, and sludge level).&lt;/p&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Who should watch:&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Water treatment engineers, operators, instrument technicians, and superintendents who want to learn more about online instrumentation and sensor applications.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Earn CEUs!&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;This live educational webinar will be 50 minutes with 10 minutes for Q&amp;amp;A. After the webinar, attendees are eligible to receive a certificate awarding 0.1 CEUs (1 PDH).&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;On-Demand - Best Practices for Online Sensor Maintenance Parts 1 &amp;amp; 3&lt;/strong&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://video.ysi.com/webinar-best-practices-for-online"&gt;Watch part one of the series&lt;/a&gt;, which covers maintenance procedures and best practices for YSI IQ SensorNet&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/fdo"&gt;FDO&lt;/a&gt;&amp;nbsp;(dissolved oxygen),&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/sensolyt"&gt;SensoLyt&lt;/a&gt;&amp;nbsp;(pH/ORP), and&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/varion"&gt;VARiON ISE&lt;/a&gt;&amp;nbsp;(ammonium/nitrate) sensors.&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/best-practices-for-online-sensor-maintenance-part-3"&gt;Watch part three of the series&lt;/a&gt;, which covers &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://video.ysi.com/alyza-iq-overview"&gt;Alyza IQ&lt;/a&gt; (ammonium, orthophosphate) and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://video.ysi.com/ysi-3017m-chlorine-analyzer"&gt;3017M&lt;/a&gt; (chlorine) wet-chemistry analyzers.&amp;nbsp;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/webinar-best-practices-for-sensor"&gt;&lt;img src="http://video.ysi.com/64968567/83733523/c0289bd24dbe8258e895dd0428fc7363/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=c0289bd24dbe8258e895dd0428fc7363&amp;source=podcast&amp;photo%5fid=83733523" width="625" height="391" type="text/html" medium="video" duration="2761" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968567/83733523/c0289bd24dbe8258e895dd0428fc7363/standard/download-8-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968567/83733523/c0289bd24dbe8258e895dd0428fc7363/standard/download-8-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
            <category>wastewater process monitoring</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968555/81233270/b4f145040342fc3f8e6306481dd13ebc/audio/podcast/81233270-8-audio.mp3" type="audio/mp3" length="45511504"/>
            <title>Webinar | Best Practices for Online Sensor Maintenance Part 1</title>
            <link>http://video.ysi.com/webinar-best-practices-for-online</link>
            <description>&lt;p&gt;&lt;p&gt;Part one of our new webinar series,&amp;nbsp;&lt;strong&gt;&lt;em&gt;How to Get Optimal Data with Online Instrumentation.&amp;nbsp;&lt;/em&gt;&lt;/strong&gt;In this four-part series, we’ll review best practices for maintaining online sensors and analyzers, managing data, and establishing a standard operating procedure for maintenance.&lt;br&gt;&lt;br&gt;Not all data is created equal. Quality data is essential for optimized process control – proper maintenance of online instrumentation results in maximum sensor performance and, ultimately, better data to help you make informed decisions.&lt;br&gt;&lt;strong&gt;&lt;br&gt;In part one&lt;/strong&gt;, we showcase live, hands-on demonstrations of maintenance procedures for YSI online sensors and share best practices for maintaining each sensor type.&amp;nbsp;&lt;br&gt;&lt;strong&gt;&lt;br&gt;You’ll learn the following:&lt;/strong&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;&lt;p&gt;Which wastewater components are known to skew online data and/or foul instrumentation&lt;/p&gt;&lt;/li&gt;&lt;li&gt;&lt;p&gt;Best practices for maintaining sensors and how to get the best data&lt;/p&gt;&lt;/li&gt;&lt;li&gt;&lt;p&gt;How to perform basic maintenance procedures for YSI IQ SensorNet &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/fdo"&gt;FDO&lt;/a&gt; (dissolved oxygen), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/sensolyt"&gt;SensoLyt&lt;/a&gt; (pH/ORP), and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/varion"&gt;VARiON ISE&lt;/a&gt;&amp;nbsp;(ammonium/nitrate) sensors&lt;/p&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;strong&gt;Who should watch:&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Water treatment engineers, operators, instrument technicians, and superintendents who want to learn more about online instrumentation and sensor applications.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Earn CEUs!&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;This live educational webinar lasts 50 minutes with 10 minutes for Q&amp;amp;A. After watching the webinar, attendees are eligible to receive a certificate awarding 0.1 CEUs (1 PDH).&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;On-Demand - Best Practices for Online Sensor Maintenance Parts 2 &amp;amp; 3&lt;/strong&gt;&lt;br&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/best-practices-for-online-sensor-maintenance-part-2"&gt;Watch part two of the series&lt;/a&gt;, which covers the&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visolid"&gt;ViSolid&lt;/a&gt;&amp;nbsp;(TSS),&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visoturb"&gt;VisoTurb&lt;/a&gt;&amp;nbsp;(turbidity),&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/file%20library/documents/guides/uv-uv-vis-sensor-application-guide.pdf"&gt;UV-Vis&lt;/a&gt;&amp;nbsp;(nitrate, COD, BOD, etc.), and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/ifl"&gt;IFL&lt;/a&gt; (sludge level) sensors.&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/best-practices-for-online-sensor-maintenance-part-3"&gt;Watch part three of the series&lt;/a&gt;, which covers&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://video.ysi.com/alyza-iq-overview"&gt;Alyza IQ&lt;/a&gt;&amp;nbsp;(ammonium, orthophosphate) and&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://video.ysi.com/ysi-3017m-chlorine-analyzer"&gt;3017M&lt;/a&gt;&amp;nbsp;(chlorine) wet-chemistry analyzers.&amp;nbsp;&lt;br&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/webinar-best-practices-for-online"&gt;&lt;img src="http://video.ysi.com/64968555/81233270/b4f145040342fc3f8e6306481dd13ebc/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/81233270</guid>
            <pubDate>Mon, 07 Nov 2022 11:36:00 GMT</pubDate>
            <media:title>Webinar | Best Practices for Online Sensor Maintenance Part 1</media:title>
            <itunes:summary>Part one of our new webinar series,How to Get Optimal Data with Online Instrumentation.In this four-part series, we’ll review best practices for maintaining online sensors and analyzers, managing data, and establishing a standard operating procedure for maintenance.Not all data is created equal. Quality data is essential for optimized process control – proper maintenance of online instrumentation results in maximum sensor performance and, ultimately, better data to help you make informed decisions.In part one, we showcase live, hands-on demonstrations of maintenance procedures for YSI online sensors and share best practices for maintaining each sensor type.You’ll learn the following:Which wastewater components are known to skew online data and/or foul instrumentationBest practices for maintaining sensors and how to get the best dataHow to perform basic maintenance procedures for YSI IQ SensorNet FDO (dissolved oxygen), SensoLyt (pH/ORP), and VARiON ISE(ammonium/nitrate) sensorsWho should watch:Water treatment engineers, operators, instrument technicians, and superintendents who want to learn more about online instrumentation and sensor applications.Earn CEUs!This live educational webinar lasts 50 minutes with 10 minutes for QA. After watching the webinar, attendees are eligible to receive a certificate awarding 0.1 CEUs (1 PDH).On-Demand - Best Practices for Online Sensor Maintenance Parts 2  3Watch part two of the series, which covers theViSolid(TSS),VisoTurb(turbidity),UV-Vis(nitrate, COD, BOD, etc.), and IFL (sludge level) sensors.Watch part three of the series, which coversAlyza IQ(ammonium, orthophosphate) and3017M(chlorine) wet-chemistry analyzers.</itunes:summary>
            <itunes:subtitle>Part one of our new webinar series,How to Get Optimal Data with Online Instrumentation.In this four-part series, we’ll review best practices for maintaining online sensors and analyzers, managing data, and establishing a standard operating...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:03:13</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;Part one of our new webinar series,&amp;nbsp;&lt;strong&gt;&lt;em&gt;How to Get Optimal Data with Online Instrumentation.&amp;nbsp;&lt;/em&gt;&lt;/strong&gt;In this four-part series, we’ll review best practices for maintaining online sensors and analyzers, managing data, and establishing a standard operating procedure for maintenance.&lt;br&gt;&lt;br&gt;Not all data is created equal. Quality data is essential for optimized process control – proper maintenance of online instrumentation results in maximum sensor performance and, ultimately, better data to help you make informed decisions.&lt;br&gt;&lt;strong&gt;&lt;br&gt;In part one&lt;/strong&gt;, we showcase live, hands-on demonstrations of maintenance procedures for YSI online sensors and share best practices for maintaining each sensor type.&amp;nbsp;&lt;br&gt;&lt;strong&gt;&lt;br&gt;You’ll learn the following:&lt;/strong&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;&lt;p&gt;Which wastewater components are known to skew online data and/or foul instrumentation&lt;/p&gt;&lt;/li&gt;&lt;li&gt;&lt;p&gt;Best practices for maintaining sensors and how to get the best data&lt;/p&gt;&lt;/li&gt;&lt;li&gt;&lt;p&gt;How to perform basic maintenance procedures for YSI IQ SensorNet &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/fdo"&gt;FDO&lt;/a&gt; (dissolved oxygen), &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/sensolyt"&gt;SensoLyt&lt;/a&gt; (pH/ORP), and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/varion"&gt;VARiON ISE&lt;/a&gt;&amp;nbsp;(ammonium/nitrate) sensors&lt;/p&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;strong&gt;Who should watch:&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Water treatment engineers, operators, instrument technicians, and superintendents who want to learn more about online instrumentation and sensor applications.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Earn CEUs!&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;This live educational webinar lasts 50 minutes with 10 minutes for Q&amp;amp;A. After watching the webinar, attendees are eligible to receive a certificate awarding 0.1 CEUs (1 PDH).&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;On-Demand - Best Practices for Online Sensor Maintenance Parts 2 &amp;amp; 3&lt;/strong&gt;&lt;br&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/best-practices-for-online-sensor-maintenance-part-2"&gt;Watch part two of the series&lt;/a&gt;, which covers the&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visolid"&gt;ViSolid&lt;/a&gt;&amp;nbsp;(TSS),&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/visoturb"&gt;VisoTurb&lt;/a&gt;&amp;nbsp;(turbidity),&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/file%20library/documents/guides/uv-uv-vis-sensor-application-guide.pdf"&gt;UV-Vis&lt;/a&gt;&amp;nbsp;(nitrate, COD, BOD, etc.), and &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/ifl"&gt;IFL&lt;/a&gt; (sludge level) sensors.&lt;/p&gt;&lt;p&gt;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/webinars/best-practices-for-online-sensor-maintenance-part-3"&gt;Watch part three of the series&lt;/a&gt;, which covers&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://video.ysi.com/alyza-iq-overview"&gt;Alyza IQ&lt;/a&gt;&amp;nbsp;(ammonium, orthophosphate) and&amp;nbsp;&lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://video.ysi.com/ysi-3017m-chlorine-analyzer"&gt;3017M&lt;/a&gt;&amp;nbsp;(chlorine) wet-chemistry analyzers.&amp;nbsp;&lt;br&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/webinar-best-practices-for-online"&gt;&lt;img src="http://video.ysi.com/64968555/81233270/b4f145040342fc3f8e6306481dd13ebc/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=b4f145040342fc3f8e6306481dd13ebc&amp;source=podcast&amp;photo%5fid=81233270" width="625" height="391" type="text/html" medium="video" duration="3793" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968555/81233270/b4f145040342fc3f8e6306481dd13ebc/standard/download-8-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968555/81233270/b4f145040342fc3f8e6306481dd13ebc/standard/download-8-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
            <category>online monitoring</category>
            <category>wastewater</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968578/76797521/9e87b8962942fc891f9226557128ccaf/audio/podcast/76797521-7-audio.mp3" type="audio/mp3" length="1170946"/>
            <title>IQ SensorNet | How to Measure 5 Parameters with One UV-Vis Sensor</title>
            <link>http://video.ysi.com/iq-sensornet-how-to-measure-5</link>
            <description>&lt;p&gt;YSI UV-Vis sensors can measure up to five parameters on a single sensor. This video demonstrates how to adjust the number of sensors displayed on a single sensor.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-how-to-measure-5"&gt;&lt;img src="http://video.ysi.com/64968578/76797521/9e87b8962942fc891f9226557128ccaf/standard/download-7-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/76797521</guid>
            <pubDate>Fri, 05 Aug 2022 11:00:04 GMT</pubDate>
            <media:title>IQ SensorNet | How to Measure 5 Parameters with One UV-Vis Sensor</media:title>
            <itunes:summary>YSI UV-Vis sensors can measure up to five parameters on a single sensor. This video demonstrates how to adjust the number of sensors displayed on a single sensor.</itunes:summary>
            <itunes:subtitle>YSI UV-Vis sensors can measure up to five parameters on a single sensor. This video demonstrates how to adjust the number of sensors displayed on a single sensor.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:37</itunes:duration>
            <media:description type="html">&lt;p&gt;YSI UV-Vis sensors can measure up to five parameters on a single sensor. This video demonstrates how to adjust the number of sensors displayed on a single sensor.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-how-to-measure-5"&gt;&lt;img src="http://video.ysi.com/64968578/76797521/9e87b8962942fc891f9226557128ccaf/standard/download-7-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=9e87b8962942fc891f9226557128ccaf&amp;source=podcast&amp;photo%5fid=76797521" width="625" height="352" type="text/html" medium="video" duration="97" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968578/76797521/9e87b8962942fc891f9226557128ccaf/standard/download-7-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968578/76797521/9e87b8962942fc891f9226557128ccaf/standard/download-7-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968571/75538885/2560c9fd6607782e8a15fe616c95962c/audio/podcast/75538885-8-audio.mp3" type="audio/mp3" length="595729"/>
            <title>IQ SensorNet | Replacing an FDO Sensor Cap</title>
            <link>http://video.ysi.com/iq-sensornet-replacing-an-fdo</link>
            <description>&lt;p&gt;The IQ SensorNet FDO 700 IQ is easy to use with routine cleaning and sensor cap replacement every 2-5 years. This video demonstrates how to replace the sensor cap of an FDO sensor.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-replacing-an-fdo"&gt;&lt;img src="http://video.ysi.com/64968571/75538885/2560c9fd6607782e8a15fe616c95962c/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75538885</guid>
            <pubDate>Fri, 05 Aug 2022 10:32:00 GMT</pubDate>
            <media:title>IQ SensorNet | Replacing an FDO Sensor Cap</media:title>
            <itunes:summary>The IQ SensorNet FDO 700 IQ is easy to use with routine cleaning and sensor cap replacement every 2-5 years. This video demonstrates how to replace the sensor cap of an FDO sensor.</itunes:summary>
            <itunes:subtitle>The IQ SensorNet FDO 700 IQ is easy to use with routine cleaning and sensor cap replacement every 2-5 years. This video demonstrates how to replace the sensor cap of an FDO sensor.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>00:50</itunes:duration>
            <media:description type="html">&lt;p&gt;The IQ SensorNet FDO 700 IQ is easy to use with routine cleaning and sensor cap replacement every 2-5 years. This video demonstrates how to replace the sensor cap of an FDO sensor.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-replacing-an-fdo"&gt;&lt;img src="http://video.ysi.com/64968571/75538885/2560c9fd6607782e8a15fe616c95962c/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=2560c9fd6607782e8a15fe616c95962c&amp;source=podcast&amp;photo%5fid=75538885" width="625" height="352" type="text/html" medium="video" duration="50" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968571/75538885/2560c9fd6607782e8a15fe616c95962c/standard/download-8-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968571/75538885/2560c9fd6607782e8a15fe616c95962c/standard/download-8-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968577/75538962/e4282969342647abb77562e90cf86dca/audio/podcast/75538962-8-audio.mp3" type="audio/mp3" length="1753372"/>
            <title>IQ SensorNet | Spectral Sensors - How to Perform a Sensor Check</title>
            <link>http://video.ysi.com/iq-sensornet-spectral-sensors</link>
            <description>&lt;p&gt;Sensor checks assess the functionality of an IQ SensorNet UV/UV-Vis sensor. This video describes when a sensor check is needed and how to perform one.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-spectral-sensors"&gt;&lt;img src="http://video.ysi.com/64968577/75538962/e4282969342647abb77562e90cf86dca/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75538962</guid>
            <pubDate>Fri, 05 Aug 2022 10:29:58 GMT</pubDate>
            <media:title>IQ SensorNet | Spectral Sensors - How to Perform a Sensor Check</media:title>
            <itunes:summary>Sensor checks assess the functionality of an IQ SensorNet UV/UV-Vis sensor. This video describes when a sensor check is needed and how to perform one.</itunes:summary>
            <itunes:subtitle>Sensor checks assess the functionality of an IQ SensorNet UV/UV-Vis sensor. This video describes when a sensor check is needed and how to perform one.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>02:26</itunes:duration>
            <media:description type="html">&lt;p&gt;Sensor checks assess the functionality of an IQ SensorNet UV/UV-Vis sensor. This video describes when a sensor check is needed and how to perform one.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-spectral-sensors"&gt;&lt;img src="http://video.ysi.com/64968577/75538962/e4282969342647abb77562e90cf86dca/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=e4282969342647abb77562e90cf86dca&amp;source=podcast&amp;photo%5fid=75538962" width="625" height="352" type="text/html" medium="video" duration="146" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968577/75538962/e4282969342647abb77562e90cf86dca/standard/download-8-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968577/75538962/e4282969342647abb77562e90cf86dca/standard/download-8-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968559/75538990/6a25454d2270f9c3612a315109f6b40d/audio/podcast/75538990-7-audio.mp3" type="audio/mp3" length="736477"/>
            <title>IQ SensorNet | Universal Sensor Cable Attachment</title>
            <link>http://video.ysi.com/iq-sensornet-universal-sensor</link>
            <description>&lt;p&gt;YSI sensors can be connected to an IQ SensorNet system with any cable, making replacement of components and troubleshooting easy!&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-universal-sensor"&gt;&lt;img src="http://video.ysi.com/64968559/75538990/6a25454d2270f9c3612a315109f6b40d/standard/download-7-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75538990</guid>
            <pubDate>Fri, 05 Aug 2022 10:17:46 GMT</pubDate>
            <media:title>IQ SensorNet | Universal Sensor Cable Attachment</media:title>
            <itunes:summary>YSI sensors can be connected to an IQ SensorNet system with any cable, making replacement of components and troubleshooting easy!</itunes:summary>
            <itunes:subtitle>YSI sensors can be connected to an IQ SensorNet system with any cable, making replacement of components and troubleshooting easy!</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:01</itunes:duration>
            <media:description type="html">&lt;p&gt;YSI sensors can be connected to an IQ SensorNet system with any cable, making replacement of components and troubleshooting easy!&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-universal-sensor"&gt;&lt;img src="http://video.ysi.com/64968559/75538990/6a25454d2270f9c3612a315109f6b40d/standard/download-7-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=6a25454d2270f9c3612a315109f6b40d&amp;source=podcast&amp;photo%5fid=75538990" width="625" height="352" type="text/html" medium="video" duration="61" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968559/75538990/6a25454d2270f9c3612a315109f6b40d/standard/download-7-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968559/75538990/6a25454d2270f9c3612a315109f6b40d/standard/download-7-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968571/75538995/5fe9b9caeff1c9336c2393e259a3bbf5/audio/podcast/75538995-6-audio.mp3" type="audio/mp3" length="1093832"/>
            <title>IQ SensorNet | IFL Sludge Level Sensor Installation</title>
            <link>http://video.ysi.com/iq-sensornet-ifl-sludge-level</link>
            <description>&lt;p&gt;&lt;p&gt;The IFL 700 IQ sludge level sensor must be properly
installed and set up for accurate sludge detection. This video will demonstrate
how to assemble an IFL mount in a clarifier without a rake arm.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-ifl-sludge-level"&gt;&lt;img src="http://video.ysi.com/64968571/75538995/5fe9b9caeff1c9336c2393e259a3bbf5/standard/download-6-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75538995</guid>
            <pubDate>Fri, 05 Aug 2022 10:11:21 GMT</pubDate>
            <media:title>IQ SensorNet | IFL Sludge Level Sensor Installation</media:title>
            <itunes:summary>The IFL 700 IQ sludge level sensor must be properly
installed and set up for accurate sludge detection. This video will demonstrate
how to assemble an IFL mount in a clarifier without a rake arm.</itunes:summary>
            <itunes:subtitle>The IFL 700 IQ sludge level sensor must be properly
installed and set up for accurate sludge detection. This video will demonstrate
how to assemble an IFL mount in a clarifier without a rake arm.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:31</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;The IFL 700 IQ sludge level sensor must be properly
installed and set up for accurate sludge detection. This video will demonstrate
how to assemble an IFL mount in a clarifier without a rake arm.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-ifl-sludge-level"&gt;&lt;img src="http://video.ysi.com/64968571/75538995/5fe9b9caeff1c9336c2393e259a3bbf5/standard/download-6-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=5fe9b9caeff1c9336c2393e259a3bbf5&amp;source=podcast&amp;photo%5fid=75538995" width="625" height="352" type="text/html" medium="video" duration="91" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968571/75538995/5fe9b9caeff1c9336c2393e259a3bbf5/standard/download-6-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968571/75538995/5fe9b9caeff1c9336c2393e259a3bbf5/standard/download-6-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968568/75538957/23c856874263f109bceecdadd80a48c4/audio/podcast/75538957-8-audio.mp3" type="audio/mp3" length="2437362"/>
            <title>IQ SensorNet | Changing ISE Electrodes</title>
            <link>http://video.ysi.com/iq-sensornet-changing-ise</link>
            <description>&lt;p&gt;Learn how to change IQ SensorNet ISE electrodes. The YSI VARiON, AmmoLyt, and NitraLyt sensors rely on clean, working electrodes to measure accurately. Since YSI’s ISE electrodes have a lifespan of 18+ months, they must be replaced routinely or as needed.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-changing-ise"&gt;&lt;img src="http://video.ysi.com/64968568/75538957/23c856874263f109bceecdadd80a48c4/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75538957</guid>
            <pubDate>Wed, 27 Apr 2022 13:21:58 GMT</pubDate>
            <media:title>IQ SensorNet | Changing ISE Electrodes</media:title>
            <itunes:summary>Learn how to change IQ SensorNet ISE electrodes. The YSI VARiON, AmmoLyt, and NitraLyt sensors rely on clean, working electrodes to measure accurately. Since YSI’s ISE electrodes have a lifespan of 18+ months, they must be replaced routinely or as needed.</itunes:summary>
            <itunes:subtitle>Learn how to change IQ SensorNet ISE electrodes. The YSI VARiON, AmmoLyt, and NitraLyt sensors rely on clean, working electrodes to measure accurately. Since YSI’s ISE electrodes have a lifespan of 18+ months, they must be replaced routinely or as...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>03:23</itunes:duration>
            <media:description type="html">&lt;p&gt;Learn how to change IQ SensorNet ISE electrodes. The YSI VARiON, AmmoLyt, and NitraLyt sensors rely on clean, working electrodes to measure accurately. Since YSI’s ISE electrodes have a lifespan of 18+ months, they must be replaced routinely or as needed.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-changing-ise"&gt;&lt;img src="http://video.ysi.com/64968568/75538957/23c856874263f109bceecdadd80a48c4/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=23c856874263f109bceecdadd80a48c4&amp;source=podcast&amp;photo%5fid=75538957" width="625" height="352" type="text/html" medium="video" duration="203" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968568/75538957/23c856874263f109bceecdadd80a48c4/standard/download-8-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968568/75538957/23c856874263f109bceecdadd80a48c4/standard/download-8-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968576/75538955/a4faaf802ef336251b2d3dc11f83ec95/audio/podcast/75538955-4-audio.mp3" type="audio/mp3" length="530841"/>
            <title>IQ SensorNet | Cleaning ISE Electrodes</title>
            <link>http://video.ysi.com/iq-sensornet-cleaning-ise</link>
            <description>&lt;p&gt;Learn how to clean IQ SensorNet ISE electrodes. Ensuring the electrodes of an ISE sensor (VARiON, AmmoLyt, NitraLyt) are clean is an important step in maintaining accurate ISE measurements. This video demonstrates how to maintain clean electrodes and the preferred cleaning method.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-cleaning-ise"&gt;&lt;img src="http://video.ysi.com/64968576/75538955/a4faaf802ef336251b2d3dc11f83ec95/standard/download-4-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75538955</guid>
            <pubDate>Wed, 27 Apr 2022 11:17:28 GMT</pubDate>
            <media:title>IQ SensorNet | Cleaning ISE Electrodes</media:title>
            <itunes:summary>Learn how to clean IQ SensorNet ISE electrodes. Ensuring the electrodes of an ISE sensor (VARiON, AmmoLyt, NitraLyt) are clean is an important step in maintaining accurate ISE measurements. This video demonstrates how to maintain clean electrodes and the preferred cleaning method.</itunes:summary>
            <itunes:subtitle>Learn how to clean IQ SensorNet ISE electrodes. Ensuring the electrodes of an ISE sensor (VARiON, AmmoLyt, NitraLyt) are clean is an important step in maintaining accurate ISE measurements. This video demonstrates how to maintain clean electrodes...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>00:44</itunes:duration>
            <media:description type="html">&lt;p&gt;Learn how to clean IQ SensorNet ISE electrodes. Ensuring the electrodes of an ISE sensor (VARiON, AmmoLyt, NitraLyt) are clean is an important step in maintaining accurate ISE measurements. This video demonstrates how to maintain clean electrodes and the preferred cleaning method.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-cleaning-ise"&gt;&lt;img src="http://video.ysi.com/64968576/75538955/a4faaf802ef336251b2d3dc11f83ec95/standard/download-4-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=a4faaf802ef336251b2d3dc11f83ec95&amp;source=podcast&amp;photo%5fid=75538955" width="625" height="352" type="text/html" medium="video" duration="44" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968576/75538955/a4faaf802ef336251b2d3dc11f83ec95/standard/download-4-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968576/75538955/a4faaf802ef336251b2d3dc11f83ec95/standard/download-4-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968561/75538953/7428cad98f223cba7445d021870695d6/audio/podcast/75538953-15-audio.mp3" type="audio/mp3" length="648079"/>
            <title>IQ SensorNet | How to Sample for Matrix Adjustment of ISE Electrodes</title>
            <link>http://video.ysi.com/iq-sensornet-how-to-sample-for</link>
            <description>&lt;p&gt;Learn how to sample for matrix adjustment of IQ SensorNet's ISE electrodes. Matrix Adjustments match the VARiON 700 IQ’s readings to a lab reference reading. Proper sampling techniques will ensure your lab reference measurements are an accurate reference to adjust your sensor’s readings.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-how-to-sample-for"&gt;&lt;img src="http://video.ysi.com/64968561/75538953/7428cad98f223cba7445d021870695d6/standard/download-15-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75538953</guid>
            <pubDate>Wed, 27 Apr 2022 11:17:17 GMT</pubDate>
            <media:title>IQ SensorNet | How to Sample for Matrix Adjustment of ISE Electrodes</media:title>
            <itunes:summary>Learn how to sample for matrix adjustment of IQ SensorNet's ISE electrodes. Matrix Adjustments match the VARiON 700 IQ’s readings to a lab reference reading. Proper sampling techniques will ensure your lab reference measurements are an accurate reference to adjust your sensor’s readings.</itunes:summary>
            <itunes:subtitle>Learn how to sample for matrix adjustment of IQ SensorNet's ISE electrodes. Matrix Adjustments match the VARiON 700 IQ’s readings to a lab reference reading. Proper sampling techniques will ensure your lab reference measurements are an accurate...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>00:54</itunes:duration>
            <media:description type="html">&lt;p&gt;Learn how to sample for matrix adjustment of IQ SensorNet's ISE electrodes. Matrix Adjustments match the VARiON 700 IQ’s readings to a lab reference reading. Proper sampling techniques will ensure your lab reference measurements are an accurate reference to adjust your sensor’s readings.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-how-to-sample-for"&gt;&lt;img src="http://video.ysi.com/64968561/75538953/7428cad98f223cba7445d021870695d6/standard/download-15-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=7428cad98f223cba7445d021870695d6&amp;source=podcast&amp;photo%5fid=75538953" width="625" height="352" type="text/html" medium="video" duration="54" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968561/75538953/7428cad98f223cba7445d021870695d6/standard/download-15-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968561/75538953/7428cad98f223cba7445d021870695d6/standard/download-15-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968577/75296486/86832272d82ea000828f11233de9ddd6/audio/podcast/75296486-13-audio.mp3" type="audio/mp3" length="337744"/>
            <title>IQ SensorNet | FDO Dissolved Oxygen Sensors</title>
            <link>http://video.ysi.com/iq-sensornet-fdo-dissolved-oxygen</link>
            <description>&lt;p&gt;The IQ SensorNet FDO is a luminescence-based, optical sensor for continuous DO monitoring that can help optimize your aeration system and lower energy costs.
&lt;p&gt;YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-fdo-dissolved-oxygen"&gt;&lt;img src="http://video.ysi.com/64968577/75296486/86832272d82ea000828f11233de9ddd6/standard/download-13-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75296486</guid>
            <pubDate>Wed, 20 Apr 2022 11:08:32 GMT</pubDate>
            <media:title>IQ SensorNet | FDO Dissolved Oxygen Sensors</media:title>
            <itunes:summary>The IQ SensorNet FDO is a luminescence-based, optical sensor for continuous DO monitoring that can help optimize your aeration system and lower energy costs.
YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.</itunes:summary>
            <itunes:subtitle>The IQ SensorNet FDO is a luminescence-based, optical sensor for continuous DO monitoring that can help optimize your aeration system and lower energy costs.
YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>00:28</itunes:duration>
            <media:description type="html">&lt;p&gt;The IQ SensorNet FDO is a luminescence-based, optical sensor for continuous DO monitoring that can help optimize your aeration system and lower energy costs.
&lt;p&gt;YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-fdo-dissolved-oxygen"&gt;&lt;img src="http://video.ysi.com/64968577/75296486/86832272d82ea000828f11233de9ddd6/standard/download-13-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=86832272d82ea000828f11233de9ddd6&amp;source=podcast&amp;photo%5fid=75296486" width="625" height="352" type="text/html" medium="video" duration="28" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968577/75296486/86832272d82ea000828f11233de9ddd6/standard/download-13-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968577/75296486/86832272d82ea000828f11233de9ddd6/standard/download-13-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968571/75296457/cf4124013c11147f5f0de48b81723ff1/audio/podcast/75296457-12-audio.mp3" type="audio/mp3" length="502942"/>
            <title>IQ SensorNet | UltraSonic Cleaning for Spectral Sensors</title>
            <link>http://video.ysi.com/iq-sensornet-ultrasonic-cleaning-1</link>
            <description>&lt;p&gt;IQ SensorNet's UV and UV/VIS sensors are optical-based spectrophotometers built into rugged, corrosion-resistant probes designed to measure accurately in harsh applications. All UV/UV-VIs sensors utilize UltraClean technology - ultrasonic cleaning to prevent fouling and lower maintenance requirements.
&lt;p&gt;YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-ultrasonic-cleaning-1"&gt;&lt;img src="http://video.ysi.com/64968571/75296457/cf4124013c11147f5f0de48b81723ff1/standard/download-12-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75296457</guid>
            <pubDate>Wed, 20 Apr 2022 10:58:27 GMT</pubDate>
            <media:title>IQ SensorNet | UltraSonic Cleaning for Spectral Sensors</media:title>
            <itunes:summary>IQ SensorNet's UV and UV/VIS sensors are optical-based spectrophotometers built into rugged, corrosion-resistant probes designed to measure accurately in harsh applications. All UV/UV-VIs sensors utilize UltraClean technology - ultrasonic cleaning to prevent fouling and lower maintenance requirements.
YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.</itunes:summary>
            <itunes:subtitle>IQ SensorNet's UV and UV/VIS sensors are optical-based spectrophotometers built into rugged, corrosion-resistant probes designed to measure accurately in harsh applications. All UV/UV-VIs sensors utilize UltraClean technology - ultrasonic cleaning...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>00:42</itunes:duration>
            <media:description type="html">&lt;p&gt;IQ SensorNet's UV and UV/VIS sensors are optical-based spectrophotometers built into rugged, corrosion-resistant probes designed to measure accurately in harsh applications. All UV/UV-VIs sensors utilize UltraClean technology - ultrasonic cleaning to prevent fouling and lower maintenance requirements.
&lt;p&gt;YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-ultrasonic-cleaning-1"&gt;&lt;img src="http://video.ysi.com/64968571/75296457/cf4124013c11147f5f0de48b81723ff1/standard/download-12-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=cf4124013c11147f5f0de48b81723ff1&amp;source=podcast&amp;photo%5fid=75296457" width="625" height="352" type="text/html" medium="video" duration="42" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968571/75296457/cf4124013c11147f5f0de48b81723ff1/standard/download-12-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968571/75296457/cf4124013c11147f5f0de48b81723ff1/standard/download-12-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968580/75296427/4b631250aa21c403dcc417edb9ae0bd1/audio/podcast/75296427-20-audio.mp3" type="audio/mp3" length="2113235"/>
            <title>IQ Sensornet | Plug-n-Play Design with Stack Mounting</title>
            <link>http://video.ysi.com/iq-sensornet-plug-n-play-design</link>
            <description>&lt;p&gt;IQ SensorNet's plug-n-play design allows for easy module stacking without extra wiring.
&lt;p&gt;YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-plug-n-play-design"&gt;&lt;img src="http://video.ysi.com/64968580/75296427/4b631250aa21c403dcc417edb9ae0bd1/standard/download-20-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75296427</guid>
            <pubDate>Wed, 20 Apr 2022 10:50:34 GMT</pubDate>
            <media:title>IQ Sensornet | Plug-n-Play Design with Stack Mounting</media:title>
            <itunes:summary>IQ SensorNet's plug-n-play design allows for easy module stacking without extra wiring.
YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.</itunes:summary>
            <itunes:subtitle>IQ SensorNet's plug-n-play design allows for easy module stacking without extra wiring.
YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>02:56</itunes:duration>
            <media:description type="html">&lt;p&gt;IQ SensorNet's plug-n-play design allows for easy module stacking without extra wiring.
&lt;p&gt;YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-plug-n-play-design"&gt;&lt;img src="http://video.ysi.com/64968580/75296427/4b631250aa21c403dcc417edb9ae0bd1/standard/download-20-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=4b631250aa21c403dcc417edb9ae0bd1&amp;source=podcast&amp;photo%5fid=75296427" width="625" height="352" type="text/html" medium="video" duration="176" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968580/75296427/4b631250aa21c403dcc417edb9ae0bd1/standard/download-20-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968580/75296427/4b631250aa21c403dcc417edb9ae0bd1/standard/download-20-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968555/75296436/be53ad83d41c72d6fe4927e477688b86/audio/podcast/75296436-25-audio.mp3" type="audio/mp3" length="855909"/>
            <title>IQ SensorNet | UltraSonic Cleaning for ViSolid TSS Sensors</title>
            <link>http://video.ysi.com/iq-sensornet-ultrasonic-cleaning</link>
            <description>&lt;p&gt;IQ SensorNet's ViSolid sensor is a reflectance-based TSS (total suspended solids) probe that features UltraClean technology, which prevents fouling and lowers maintenance requirements.
&lt;p&gt;YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-ultrasonic-cleaning"&gt;&lt;img src="http://video.ysi.com/64968555/75296436/be53ad83d41c72d6fe4927e477688b86/standard/download-25-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75296436</guid>
            <pubDate>Wed, 20 Apr 2022 10:50:15 GMT</pubDate>
            <media:title>IQ SensorNet | UltraSonic Cleaning for ViSolid TSS Sensors</media:title>
            <itunes:summary>IQ SensorNet's ViSolid sensor is a reflectance-based TSS (total suspended solids) probe that features UltraClean technology, which prevents fouling and lowers maintenance requirements.
YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.</itunes:summary>
            <itunes:subtitle>IQ SensorNet's ViSolid sensor is a reflectance-based TSS (total suspended solids) probe that features UltraClean technology, which prevents fouling and lowers maintenance requirements.
YSI IQ SensorNet is a system of online controllers, sensors,...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:11</itunes:duration>
            <media:description type="html">&lt;p&gt;IQ SensorNet's ViSolid sensor is a reflectance-based TSS (total suspended solids) probe that features UltraClean technology, which prevents fouling and lowers maintenance requirements.
&lt;p&gt;YSI IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-ultrasonic-cleaning"&gt;&lt;img src="http://video.ysi.com/64968555/75296436/be53ad83d41c72d6fe4927e477688b86/standard/download-25-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=be53ad83d41c72d6fe4927e477688b86&amp;source=podcast&amp;photo%5fid=75296436" width="625" height="352" type="text/html" medium="video" duration="71" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968555/75296436/be53ad83d41c72d6fe4927e477688b86/standard/download-25-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968555/75296436/be53ad83d41c72d6fe4927e477688b86/standard/download-25-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968561/75296393/980ee19a930f888cb7f1a65e106e044f/audio/podcast/75296393-12-audio.mp3" type="audio/mp3" length="417992"/>
            <title>IQ SensorNet | Modular Design Enables Customer Solutions</title>
            <link>http://video.ysi.com/iq-sensornet-modular-design</link>
            <description>&lt;p&gt;YSI's IQ SensorNet is a scalable solution - add sensors and communication outputs at any time to any location, or exchange them with ease.
&lt;p&gt;IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-modular-design"&gt;&lt;img src="http://video.ysi.com/64968561/75296393/980ee19a930f888cb7f1a65e106e044f/standard/download-12-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75296393</guid>
            <pubDate>Wed, 20 Apr 2022 10:41:43 GMT</pubDate>
            <media:title>IQ SensorNet | Modular Design Enables Customer Solutions</media:title>
            <itunes:summary>YSI's IQ SensorNet is a scalable solution - add sensors and communication outputs at any time to any location, or exchange them with ease.
IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.</itunes:summary>
            <itunes:subtitle>YSI's IQ SensorNet is a scalable solution - add sensors and communication outputs at any time to any location, or exchange them with ease.
IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>00:35</itunes:duration>
            <media:description type="html">&lt;p&gt;YSI's IQ SensorNet is a scalable solution - add sensors and communication outputs at any time to any location, or exchange them with ease.
&lt;p&gt;IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-modular-design"&gt;&lt;img src="http://video.ysi.com/64968561/75296393/980ee19a930f888cb7f1a65e106e044f/standard/download-12-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=980ee19a930f888cb7f1a65e106e044f&amp;source=podcast&amp;photo%5fid=75296393" width="625" height="352" type="text/html" medium="video" duration="35" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968561/75296393/980ee19a930f888cb7f1a65e106e044f/standard/download-12-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968561/75296393/980ee19a930f888cb7f1a65e106e044f/standard/download-12-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968576/75294563/a51faa257bc387ede7001a96f15de42e/audio/podcast/75294563-13-audio.mp3" type="audio/mp3" length="728013"/>
            <title>IQ SensorNet | Portable Display Units</title>
            <link>http://video.ysi.com/iq-sensornet-portable-display</link>
            <description>&lt;p&gt;IQ SensorNet's portable display units allow additional controllers to be docked anywhere in the system.
&lt;p&gt;IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.&lt;br&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-portable-display"&gt;&lt;img src="http://video.ysi.com/64968576/75294563/a51faa257bc387ede7001a96f15de42e/standard/download-13-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/75294563</guid>
            <pubDate>Wed, 20 Apr 2022 10:34:40 GMT</pubDate>
            <media:title>IQ SensorNet | Portable Display Units</media:title>
            <itunes:summary>IQ SensorNet's portable display units allow additional controllers to be docked anywhere in the system.
IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.</itunes:summary>
            <itunes:subtitle>IQ SensorNet's portable display units allow additional controllers to be docked anywhere in the system.
IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:01</itunes:duration>
            <media:description type="html">&lt;p&gt;IQ SensorNet's portable display units allow additional controllers to be docked anywhere in the system.
&lt;p&gt;IQ SensorNet is a system of online controllers, sensors, and analyzers designed for process monitoring at wastewater treatment plants.&lt;br&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-portable-display"&gt;&lt;img src="http://video.ysi.com/64968576/75294563/a51faa257bc387ede7001a96f15de42e/standard/download-13-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=a51faa257bc387ede7001a96f15de42e&amp;source=podcast&amp;photo%5fid=75294563" width="625" height="352" type="text/html" medium="video" duration="61" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968576/75294563/a51faa257bc387ede7001a96f15de42e/standard/download-13-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968576/75294563/a51faa257bc387ede7001a96f15de42e/standard/download-13-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968566/74838905/6981491c77cca36999eee56b7bc9ddcd/audio/podcast/74838905-21-audio.mp3" type="audio/mp3" length="2747697"/>
            <title>YSI Alyza IQ | Changing Cleaning, Calibration, &amp; Measurement Intervals</title>
            <link>http://video.ysi.com/ysi-alyza-iq-changing-cleaning</link>
            <description>&lt;p&gt;This video covers how to change the cleaning, calibration, and measurements intervals on the IQ SensorNet Alyza IQ analyzer.&lt;br&gt;&lt;p&gt;To change cleaning, calibration, measuring intervals,
start by pressing the "S" button.&lt;/p&gt;&lt;p&gt;Scroll to Settings of sensors and
diff. sensors and press Okay.&amp;nbsp;&lt;/p&gt;&lt;p&gt;Highlight the far right column, press Okay. And
then press Continue.&lt;/p&gt;&lt;p&gt;This is where you will change cleaning, calibration, and
measuring intervals.&amp;nbsp;&lt;/p&gt;&lt;p&gt;Starting with the measuring interval, highlight Meas.
interval and press Okay.&lt;/p&gt;&lt;p&gt;Select the desired interval between 5 minutes and 12
hours.&lt;/p&gt;&lt;p&gt;Continuing down to Automatic Cleaning, highlight Autom.cleaning, select On,
and press Okay.&lt;/p&gt;&lt;p&gt;Underneath this listing, five new variables will pop up
including interval, which offers selections of 6 hours, 12 hours, 24, 48, and
96 hours.&lt;/p&gt;&lt;p&gt;Underneath this is Ref.time hours and Ref.time minutes. This allows
you to set what time of day the automatic cleaning cycle starts. In this
example, we are starting the cleaning cycle at 8:30 a.m.&lt;/p&gt;&lt;p&gt;Under this is
Conditioning and count of steps. Conditioning refers to the number of rinse
cycles that take place after an automatic cleaning. This is adjustable from 1
to 10 using the count of steps function.&lt;/p&gt;

&lt;p&gt;Now, moving on to the automatic calibration function.
After turning it on, four new variables will populate the first of which being
Procedure. This will allow you to choose a 1 or 2-point calibration procedure.
You will only have the 2-point option if you have installed 2 calibration
solution ChemBags.&lt;/p&gt;&lt;p&gt;Next, you will set the interval. The options are 6, 12, 24,
48, and 96 hours.&lt;/p&gt;

&lt;p&gt;The last two variables to be set are Ref.time hours and
Ref.time minutes. In this example, we are setting automatic 1-point
calibrations to occur every 12 hours starting at 12:30 p.m. After setting up
the automatic calibration, double-check that all settings on this screen are
satisfactory.&lt;/p&gt;&lt;p&gt;&lt;b&gt;Before exiting from this screen, be sure to scroll to the bottom
and press Save and quit.&lt;/b&gt; Failure to do this will cause all changed settings to
be erased.&lt;/p&gt;&lt;p&gt;This concludes how to change the cleaning, calibration, and
measurement intervals on the Alyza IQ.&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-alyza-iq-changing-cleaning"&gt;&lt;img src="http://video.ysi.com/64968566/74838905/6981491c77cca36999eee56b7bc9ddcd/standard/download-21-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/74838905</guid>
            <pubDate>Tue, 29 Mar 2022 13:54:52 GMT</pubDate>
            <media:title>YSI Alyza IQ | Changing Cleaning, Calibration, &amp; Measurement Intervals</media:title>
            <itunes:summary>This video covers how to change the cleaning, calibration, and measurements intervals on the IQ SensorNet Alyza IQ analyzer.To change cleaning, calibration, measuring intervals,
start by pressing the "S" button.Scroll to Settings of sensors and
diff. sensors and press Okay.Highlight the far right column, press Okay. And
then press Continue.This is where you will change cleaning, calibration, and
measuring intervals.Starting with the measuring interval, highlight Meas.
interval and press Okay.Select the desired interval between 5 minutes and 12
hours.Continuing down to Automatic Cleaning, highlight Autom.cleaning, select On,
and press Okay.Underneath this listing, five new variables will pop up
including interval, which offers selections of 6 hours, 12 hours, 24, 48, and
96 hours.Underneath this is Ref.time hours and Ref.time minutes. This allows
you to set what time of day the automatic cleaning cycle starts. In this
example, we are starting the cleaning cycle at 8:30 a.m.Under this is
Conditioning and count of steps. Conditioning refers to the number of rinse
cycles that take place after an automatic cleaning. This is adjustable from 1
to 10 using the count of steps function.

Now, moving on to the automatic calibration function.
After turning it on, four new variables will populate the first of which being
Procedure. This will allow you to choose a 1 or 2-point calibration procedure.
You will only have the 2-point option if you have installed 2 calibration
solution ChemBags.Next, you will set the interval. The options are 6, 12, 24,
48, and 96 hours.

The last two variables to be set are Ref.time hours and
Ref.time minutes. In this example, we are setting automatic 1-point
calibrations to occur every 12 hours starting at 12:30 p.m. After setting up
the automatic calibration, double-check that all settings on this screen are
satisfactory.Before exiting from this screen, be sure to scroll to the bottom
and press Save and quit. Failure to do this will cause all changed settings to
be erased.This concludes how to change the cleaning, calibration, and
measurement intervals on the Alyza IQ.

</itunes:summary>
            <itunes:subtitle>This video covers how to change the cleaning, calibration, and measurements intervals on the IQ SensorNet Alyza IQ analyzer.To change cleaning, calibration, measuring intervals,
start by pressing the "S" button.Scroll to Settings of sensors and...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>03:49</itunes:duration>
            <media:description type="html">&lt;p&gt;This video covers how to change the cleaning, calibration, and measurements intervals on the IQ SensorNet Alyza IQ analyzer.&lt;br&gt;&lt;p&gt;To change cleaning, calibration, measuring intervals,
start by pressing the "S" button.&lt;/p&gt;&lt;p&gt;Scroll to Settings of sensors and
diff. sensors and press Okay.&amp;nbsp;&lt;/p&gt;&lt;p&gt;Highlight the far right column, press Okay. And
then press Continue.&lt;/p&gt;&lt;p&gt;This is where you will change cleaning, calibration, and
measuring intervals.&amp;nbsp;&lt;/p&gt;&lt;p&gt;Starting with the measuring interval, highlight Meas.
interval and press Okay.&lt;/p&gt;&lt;p&gt;Select the desired interval between 5 minutes and 12
hours.&lt;/p&gt;&lt;p&gt;Continuing down to Automatic Cleaning, highlight Autom.cleaning, select On,
and press Okay.&lt;/p&gt;&lt;p&gt;Underneath this listing, five new variables will pop up
including interval, which offers selections of 6 hours, 12 hours, 24, 48, and
96 hours.&lt;/p&gt;&lt;p&gt;Underneath this is Ref.time hours and Ref.time minutes. This allows
you to set what time of day the automatic cleaning cycle starts. In this
example, we are starting the cleaning cycle at 8:30 a.m.&lt;/p&gt;&lt;p&gt;Under this is
Conditioning and count of steps. Conditioning refers to the number of rinse
cycles that take place after an automatic cleaning. This is adjustable from 1
to 10 using the count of steps function.&lt;/p&gt;

&lt;p&gt;Now, moving on to the automatic calibration function.
After turning it on, four new variables will populate the first of which being
Procedure. This will allow you to choose a 1 or 2-point calibration procedure.
You will only have the 2-point option if you have installed 2 calibration
solution ChemBags.&lt;/p&gt;&lt;p&gt;Next, you will set the interval. The options are 6, 12, 24,
48, and 96 hours.&lt;/p&gt;

&lt;p&gt;The last two variables to be set are Ref.time hours and
Ref.time minutes. In this example, we are setting automatic 1-point
calibrations to occur every 12 hours starting at 12:30 p.m. After setting up
the automatic calibration, double-check that all settings on this screen are
satisfactory.&lt;/p&gt;&lt;p&gt;&lt;b&gt;Before exiting from this screen, be sure to scroll to the bottom
and press Save and quit.&lt;/b&gt; Failure to do this will cause all changed settings to
be erased.&lt;/p&gt;&lt;p&gt;This concludes how to change the cleaning, calibration, and
measurement intervals on the Alyza IQ.&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-alyza-iq-changing-cleaning"&gt;&lt;img src="http://video.ysi.com/64968566/74838905/6981491c77cca36999eee56b7bc9ddcd/standard/download-21-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=6981491c77cca36999eee56b7bc9ddcd&amp;source=podcast&amp;photo%5fid=74838905" width="625" height="352" type="text/html" medium="video" duration="229" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968566/74838905/6981491c77cca36999eee56b7bc9ddcd/standard/download-21-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968566/74838905/6981491c77cca36999eee56b7bc9ddcd/standard/download-21-thumbnail.jpg/thumbnail.jpg"/>
            <category>wastewater</category>
            <category>wastewater monitoring</category>
            <category>wastewater process monitoring</category>
            <category>water quality monitoring</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968556/73953585/002e2029996b0dc53431a112dde1c5d8/audio/podcast/73953585-8-audio.mp3" type="audio/mp3" length="2755533"/>
            <title>YSI Titrator Inspection and Maintenance</title>
            <link>http://video.ysi.com/ysi-titrator-inspection-and</link>
            <description>&lt;p&gt;&lt;p&gt;Here are our recommendations on inspection and maintenance guidelines to ensure that you get
the most out of your YSI titrators.&amp;nbsp;&lt;/p&gt;&lt;p&gt;Before we begin today, I want to emphasize
that maintenance checks vary among laboratories. The frequency of use,
throughput capacity, and sample type can alter maintenance schedules for each
instrument. It is important to be mindful of this as you use your titration system.
Let's begin.&lt;/p&gt;

&lt;p&gt;The first and easiest step to improve your product's
lifespan is to begin with a simple cleaning. Spills happen all the time in the
lab. Be sure to wipe away any liquids or spills from your titrator with a
laboratory soft towel or a Kimwipe whenever necessary. Having a clean
instrument will ensure peak condition and optimal workflow. After the exterior
surface of the titrator is clean, we will perform an overall instrument
inspection. For heavy strain labs, we recommend inspecting your equipment on a
weekly basis. For lower strain laboratories, a monthly inspection should be
enough.&lt;/p&gt;

&lt;p&gt;To begin, check for leakage around the dosing system.
Confirm the piston is tight. If the piston is not tight, or you're having
trouble tightening it, you may want to replace the piston. Check out YSI.com to
browse our piston size options. Confirm the valve is also tight. The titration
tubes should be attached and there should be no moisture under the valve. If
there is moisture or the valve will not tighten, you may need a new one. Check
out YSI.com to browse our options.&lt;/p&gt;

&lt;p&gt;The last step in completing an inspection is to confirm
that the titration tip is free of blockages. A blocked titration tip could
prevent liquid from dispersing, leading to inaccurate titrations. We would
recommend thoroughly cleaning your dosing system every three months. It's
important that all of the parts are cleaned separately. A thorough cleaning
depends on what titrant you're using in your laboratory. For the purpose of
this video, we are going to clean the dosing system with distilled water.&lt;/p&gt;

&lt;p&gt;Our team at YSI also recommends performing a complete
technical and visual inspection every six months or twice a year. This
inspection is designed to ensure that there are no dings or external damage.
Air bubbles lead to inaccurate dosing measurements. It's important to confirm
that there are no air bubbles in your dosing components. If you see air
bubbles, continuously run the titrant through the system. Check for any
exterior damage to the titrator. Look over the instrument and ensure that there
is no obvious damage that could affect your titration. Take a closer look and
inspect the electrical components to check for rust and other physical damage.
And to round out your routine maintenance and inspection, our team at YSI
recommends certifying your unit for volumetric performance according to ISO
8655. This helps ensure that the data you produce is accurate and reliable.&lt;/p&gt;

&lt;p&gt;Many of these routine maintenance checks are simple
enough for you to do in your laboratory; however, if you ever have any issues
that you cannot seem to resolve, we are here to help. Between our in-house
support and our field service team, we can provide a solution to keep your lab
up and running. Learn more about our titration portfolio and other laboratory
solutions at YSI.com/lab-solutions.&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-titrator-inspection-and"&gt;&lt;img src="http://video.ysi.com/64968556/73953585/002e2029996b0dc53431a112dde1c5d8/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/73953585</guid>
            <pubDate>Thu, 27 Jan 2022 12:56:36 GMT</pubDate>
            <media:title>YSI Titrator Inspection and Maintenance</media:title>
            <itunes:summary>Here are our recommendations on inspection and maintenance guidelines to ensure that you get
the most out of your YSI titrators.Before we begin today, I want to emphasize
that maintenance checks vary among laboratories. The frequency of use,
throughput capacity, and sample type can alter maintenance schedules for each
instrument. It is important to be mindful of this as you use your titration system.
Let's begin.

The first and easiest step to improve your product's
lifespan is to begin with a simple cleaning. Spills happen all the time in the
lab. Be sure to wipe away any liquids or spills from your titrator with a
laboratory soft towel or a Kimwipe whenever necessary. Having a clean
instrument will ensure peak condition and optimal workflow. After the exterior
surface of the titrator is clean, we will perform an overall instrument
inspection. For heavy strain labs, we recommend inspecting your equipment on a
weekly basis. For lower strain laboratories, a monthly inspection should be
enough.

To begin, check for leakage around the dosing system.
Confirm the piston is tight. If the piston is not tight, or you're having
trouble tightening it, you may want to replace the piston. Check out YSI.com to
browse our piston size options. Confirm the valve is also tight. The titration
tubes should be attached and there should be no moisture under the valve. If
there is moisture or the valve will not tighten, you may need a new one. Check
out YSI.com to browse our options.

The last step in completing an inspection is to confirm
that the titration tip is free of blockages. A blocked titration tip could
prevent liquid from dispersing, leading to inaccurate titrations. We would
recommend thoroughly cleaning your dosing system every three months. It's
important that all of the parts are cleaned separately. A thorough cleaning
depends on what titrant you're using in your laboratory. For the purpose of
this video, we are going to clean the dosing system with distilled water.

Our team at YSI also recommends performing a complete
technical and visual inspection every six months or twice a year. This
inspection is designed to ensure that there are no dings or external damage.
Air bubbles lead to inaccurate dosing measurements. It's important to confirm
that there are no air bubbles in your dosing components. If you see air
bubbles, continuously run the titrant through the system. Check for any
exterior damage to the titrator. Look over the instrument and ensure that there
is no obvious damage that could affect your titration. Take a closer look and
inspect the electrical components to check for rust and other physical damage.
And to round out your routine maintenance and inspection, our team at YSI
recommends certifying your unit for volumetric performance according to ISO
8655. This helps ensure that the data you produce is accurate and reliable.

Many of these routine maintenance checks are simple
enough for you to do in your laboratory; however, if you ever have any issues
that you cannot seem to resolve, we are here to help. Between our in-house
support and our field service team, we can provide a solution to keep your lab
up and running. Learn more about our titration portfolio and other laboratory
solutions at YSI.com/lab-solutions.

</itunes:summary>
            <itunes:subtitle>Here are our recommendations on inspection and maintenance guidelines to ensure that you get
the most out of your YSI titrators.Before we begin today, I want to emphasize
that maintenance checks vary among laboratories. The frequency of use,...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>03:50</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;Here are our recommendations on inspection and maintenance guidelines to ensure that you get
the most out of your YSI titrators.&amp;nbsp;&lt;/p&gt;&lt;p&gt;Before we begin today, I want to emphasize
that maintenance checks vary among laboratories. The frequency of use,
throughput capacity, and sample type can alter maintenance schedules for each
instrument. It is important to be mindful of this as you use your titration system.
Let's begin.&lt;/p&gt;

&lt;p&gt;The first and easiest step to improve your product's
lifespan is to begin with a simple cleaning. Spills happen all the time in the
lab. Be sure to wipe away any liquids or spills from your titrator with a
laboratory soft towel or a Kimwipe whenever necessary. Having a clean
instrument will ensure peak condition and optimal workflow. After the exterior
surface of the titrator is clean, we will perform an overall instrument
inspection. For heavy strain labs, we recommend inspecting your equipment on a
weekly basis. For lower strain laboratories, a monthly inspection should be
enough.&lt;/p&gt;

&lt;p&gt;To begin, check for leakage around the dosing system.
Confirm the piston is tight. If the piston is not tight, or you're having
trouble tightening it, you may want to replace the piston. Check out YSI.com to
browse our piston size options. Confirm the valve is also tight. The titration
tubes should be attached and there should be no moisture under the valve. If
there is moisture or the valve will not tighten, you may need a new one. Check
out YSI.com to browse our options.&lt;/p&gt;

&lt;p&gt;The last step in completing an inspection is to confirm
that the titration tip is free of blockages. A blocked titration tip could
prevent liquid from dispersing, leading to inaccurate titrations. We would
recommend thoroughly cleaning your dosing system every three months. It's
important that all of the parts are cleaned separately. A thorough cleaning
depends on what titrant you're using in your laboratory. For the purpose of
this video, we are going to clean the dosing system with distilled water.&lt;/p&gt;

&lt;p&gt;Our team at YSI also recommends performing a complete
technical and visual inspection every six months or twice a year. This
inspection is designed to ensure that there are no dings or external damage.
Air bubbles lead to inaccurate dosing measurements. It's important to confirm
that there are no air bubbles in your dosing components. If you see air
bubbles, continuously run the titrant through the system. Check for any
exterior damage to the titrator. Look over the instrument and ensure that there
is no obvious damage that could affect your titration. Take a closer look and
inspect the electrical components to check for rust and other physical damage.
And to round out your routine maintenance and inspection, our team at YSI
recommends certifying your unit for volumetric performance according to ISO
8655. This helps ensure that the data you produce is accurate and reliable.&lt;/p&gt;

&lt;p&gt;Many of these routine maintenance checks are simple
enough for you to do in your laboratory; however, if you ever have any issues
that you cannot seem to resolve, we are here to help. Between our in-house
support and our field service team, we can provide a solution to keep your lab
up and running. Learn more about our titration portfolio and other laboratory
solutions at YSI.com/lab-solutions.&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-titrator-inspection-and"&gt;&lt;img src="http://video.ysi.com/64968556/73953585/002e2029996b0dc53431a112dde1c5d8/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=002e2029996b0dc53431a112dde1c5d8&amp;source=podcast&amp;photo%5fid=73953585" width="625" height="352" type="text/html" medium="video" duration="230" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968556/73953585/002e2029996b0dc53431a112dde1c5d8/standard/download-8-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968556/73953585/002e2029996b0dc53431a112dde1c5d8/standard/download-8-thumbnail.jpg/thumbnail.jpg"/>
            <category>carousel</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968560/71980265/04d7d7068a2b3ccf38dfbd2f8aa2fb15/audio/podcast/71980265-8-audio.mp3" type="audio/mp3" length="5339462"/>
            <title>EXO2s Sonde Unboxing &amp; Overview</title>
            <link>http://video.ysi.com/exo2s-sonde-unboxing-overview</link>
            <description>&lt;p&gt;&lt;p&gt;Hi, this is Zack Henderson, product manager for YSI, a
Xylem brand. And today, I'm super excited to do an unboxing video for our brand
new EXO2s Sonde. The first thing you might notice about this is the size
difference. Here is your standard EXO2 box size comparison with the EXO2s box. Definitely saves on space and&amp;nbsp;shipping.&amp;nbsp;&lt;/p&gt;&lt;p&gt;When you open up the box, the first thing you'll be greeted
with is our quick start guide. It's front and back. You will receive a maintenance kit that includes a syringe for cleaning
the depth sensor, and also a couple magnetic sensor installation and removal tools.&lt;/p&gt;

&lt;p&gt;In addition, we have our lubricant and a spare bulkhead
O-ring. This lubricant is absolutely critical for making sure our wet-mate
connectors stay well lubricated. And then we have a bag with a bunch of port
plugs. So we have four sensor port plugs, and then plugs for our main
connector ports and our auxiliary port. And then finally, don't lose this, this
is the USB drive containing the core software, which you'll use to interface
with the sonde. Now let's talk about the main attraction here, the sonde. So
this is the EXO2s Sonde. Let me get this box out of the way.&lt;/p&gt;

&lt;p&gt;So the EXO2s Sonde, what is the EXO2s? It is the short
version of our standard EXO2 Sonde. We basically remove the battery
compartment. So you get a much more compact package, but you do have to supply
external power. Aside from that, all the benefits of a normal EXO2 are here. So
I have a standard EXO2 conveniently set to the side here, so we can get a nice
visual on the differences. And as you can see, it is about a 40% reduction in
length. It's also a much lighter solution. So for applications that are
space-sensitive, if you wanna hide the sonde, it's a much smaller footprint.
Drone or AUV applications where weight might be a factor, this would be a
better choice. And this is also, you know, much lighter on your budget as well.
So as long as you can supply external power, this is gonna be a more
cost-effective solution than the sonde here. Also, without the internal battery
compartment, you don't have to worry about replacing alkaline batteries. So
it's a more sustainable solution as well.&lt;/p&gt;

&lt;p&gt;So let's talk about the sonde itself. So on the top, we
have the bale and the two main connector ports. We have our power and
communication port here. So this is what would be connected to your topside
monitoring system, which would allow for communication and supplying external
power. We also have our auxiliary port, which you can use to daisy-chain sondes
together. You can connect our EXO PAR sensor or a third-party sensor to it. But
most of the time, I think most users just plug this port here.&lt;/p&gt;

&lt;p&gt;And this is an EXO2, so you get seven sensor ports.
Most of the time, a central wiper will be placed in the center port here
leaving six universal ports to plug in any EXO sensors you want in your payload.
And the central wiper will keep those clean over the course of the deployment.
Also, you can see these four holes here, that is our integrated depth sensor.
So the depth sensor is built into the sonde here. Another cool thing is on the
body of the sonde, it actually tells you how far away the depth measurement is
being made from the other sensor measurements. So, I have a DO sensor here, for
example, I'm gonna plug in.&lt;/p&gt;

&lt;p&gt;So when you're measuring water quality with an EXO,
most of the measurements take place right around this area. All the sensing is
done here. So it's nice that it tells you how far, especially if it's in a
vertical orientation, how far away the depth is being measured versus all the
other sensor readings. And with core software, you can actually input an offset
for the depth sensor if you wanted to kind of match those up if it's deployed
in a vertical orientation. So that's kind of cool. One other thing I wanted to
highlight, and this is true for all of our EXO Sondes, is that we use real wet-mate
connectors. And what that means is if water was on the connector, splashed or
even submerged, ideally, you wouldn't wanna do this, but when you plug a sensor
in, there's no risk to it shorting out or anything like that.&lt;/p&gt;

&lt;p&gt;Some of our competitors that use LEMO-style connectors
with an O-ring seal or a double O-ring seal, that's all well and good but if
water gets in that port and you plug the sensor in, those pins are gonna
corrode. It's not really a factor here. But something that is important about the
wet-mate connectors on the sensor side and on the cable side is keeping them
well lubricated. I actually notice, you might see the pins glistening here, the
wet-mates come pre-lubricated. So that's cool, but you also want to make sure
to periodically apply some of that grease there to keep them well lubricated.
So one other really cool use for this would be using it with a handheld for
spot sampling applications. Go ahead and just plug this in here. All right. So
given this relatively compact form factor and the fact that it has seven sensor
ports, you get all the sensor options available on EXO, again, in a relatively
compact spot sampling package, much more easier to move around and maneuver
than the larger EXO2 Sonde. So EXO2s, definitely consider for spot sampling
applications.&lt;/p&gt;

&lt;p&gt;And with that, that's pretty much all I have to show
you in this video, but if you'd like to learn more, please visit our website at
ysi.com/exo.&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/exo2s-sonde-unboxing-overview"&gt;&lt;img src="http://video.ysi.com/64968560/71980265/04d7d7068a2b3ccf38dfbd2f8aa2fb15/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/71980265</guid>
            <pubDate>Wed, 15 Dec 2021 09:17:54 GMT</pubDate>
            <media:title>EXO2s Sonde Unboxing &amp; Overview</media:title>
            <itunes:summary>Hi, this is Zack Henderson, product manager for YSI, a
Xylem brand. And today, I'm super excited to do an unboxing video for our brand
new EXO2s Sonde. The first thing you might notice about this is the size
difference. Here is your standard EXO2 box size comparison with the EXO2s box. Definitely saves on space andshipping.When you open up the box, the first thing you'll be greeted
with is our quick start guide. It's front and back. You will receive a maintenance kit that includes a syringe for cleaning
the depth sensor, and also a couple magnetic sensor installation and removal tools.

In addition, we have our lubricant and a spare bulkhead
O-ring. This lubricant is absolutely critical for making sure our wet-mate
connectors stay well lubricated. And then we have a bag with a bunch of port
plugs. So we have four sensor port plugs, and then plugs for our main
connector ports and our auxiliary port. And then finally, don't lose this, this
is the USB drive containing the core software, which you'll use to interface
with the sonde. Now let's talk about the main attraction here, the sonde. So
this is the EXO2s Sonde. Let me get this box out of the way.

So the EXO2s Sonde, what is the EXO2s? It is the short
version of our standard EXO2 Sonde. We basically remove the battery
compartment. So you get a much more compact package, but you do have to supply
external power. Aside from that, all the benefits of a normal EXO2 are here. So
I have a standard EXO2 conveniently set to the side here, so we can get a nice
visual on the differences. And as you can see, it is about a 40% reduction in
length. It's also a much lighter solution. So for applications that are
space-sensitive, if you wanna hide the sonde, it's a much smaller footprint.
Drone or AUV applications where weight might be a factor, this would be a
better choice. And this is also, you know, much lighter on your budget as well.
So as long as you can supply external power, this is gonna be a more
cost-effective solution than the sonde here. Also, without the internal battery
compartment, you don't have to worry about replacing alkaline batteries. So
it's a more sustainable solution as well.

So let's talk about the sonde itself. So on the top, we
have the bale and the two main connector ports. We have our power and
communication port here. So this is what would be connected to your topside
monitoring system, which would allow for communication and supplying external
power. We also have our auxiliary port, which you can use to daisy-chain sondes
together. You can connect our EXO PAR sensor or a third-party sensor to it. But
most of the time, I think most users just plug this port here.

And this is an EXO2, so you get seven sensor ports.
Most of the time, a central wiper will be placed in the center port here
leaving six universal ports to plug in any EXO sensors you want in your payload.
And the central wiper will keep those clean over the course of the deployment.
Also, you can see these four holes here, that is our integrated depth sensor.
So the depth sensor is built into the sonde here. Another cool thing is on the
body of the sonde, it actually tells you how far away the depth measurement is
being made from the other sensor measurements. So, I have a DO sensor here, for
example, I'm gonna plug in.

So when you're measuring water quality with an EXO,
most of the measurements take place right around this area. All the sensing is
done here. So it's nice that it tells you how far, especially if it's in a
vertical orientation, how far away the depth is being measured versus all the
other sensor readings. And with core software, you can actually input an offset
for the depth sensor if you wanted to kind of match those up if it's deployed
in a vertical orientation. So that's kind of cool. One other thing I wanted to
highlight, and this is true for all of our EXO Sondes, is that we use real wet-mate
connectors. And what that means is if water was on the connector, splashed or
even submerged, ideally, you wouldn't wanna do this, but when you plug a sensor
in, there's no risk to it shorting out or anything like that.

Some of our competitors that use LEMO-style connectors
with an O-ring seal or a double O-ring seal, that's all well and good but if
water gets in that port and you plug the sensor in, those pins are gonna
corrode. It's not really a factor here. But something that is important about the
wet-mate connectors on the sensor side and on the cable side is keeping them
well lubricated. I actually notice, you might see the pins glistening here, the
wet-mates come pre-lubricated. So that's cool, but you also want to make sure
to periodically apply some of that grease there to keep them well lubricated.
So one other really cool use for this would be using it with a handheld for
spot sampling applications. Go ahead and just plug this in here. All right. So
given this relatively compact form factor and the fact that it has seven sensor
ports, you get all the sensor options available on EXO, again, in a relatively
compact spot sampling package, much more easier to move around and maneuver
than the larger EXO2 Sonde. So EXO2s, definitely consider for spot sampling
applications.

And with that, that's pretty much all I have to show
you in this video, but if you'd like to learn more, please visit our website at
ysi.com/exo.

</itunes:summary>
            <itunes:subtitle>Hi, this is Zack Henderson, product manager for YSI, a
Xylem brand. And today, I'm super excited to do an unboxing video for our brand
new EXO2s Sonde. The first thing you might notice about this is the size
difference. Here is your standard EXO2...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>07:25</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;Hi, this is Zack Henderson, product manager for YSI, a
Xylem brand. And today, I'm super excited to do an unboxing video for our brand
new EXO2s Sonde. The first thing you might notice about this is the size
difference. Here is your standard EXO2 box size comparison with the EXO2s box. Definitely saves on space and&amp;nbsp;shipping.&amp;nbsp;&lt;/p&gt;&lt;p&gt;When you open up the box, the first thing you'll be greeted
with is our quick start guide. It's front and back. You will receive a maintenance kit that includes a syringe for cleaning
the depth sensor, and also a couple magnetic sensor installation and removal tools.&lt;/p&gt;

&lt;p&gt;In addition, we have our lubricant and a spare bulkhead
O-ring. This lubricant is absolutely critical for making sure our wet-mate
connectors stay well lubricated. And then we have a bag with a bunch of port
plugs. So we have four sensor port plugs, and then plugs for our main
connector ports and our auxiliary port. And then finally, don't lose this, this
is the USB drive containing the core software, which you'll use to interface
with the sonde. Now let's talk about the main attraction here, the sonde. So
this is the EXO2s Sonde. Let me get this box out of the way.&lt;/p&gt;

&lt;p&gt;So the EXO2s Sonde, what is the EXO2s? It is the short
version of our standard EXO2 Sonde. We basically remove the battery
compartment. So you get a much more compact package, but you do have to supply
external power. Aside from that, all the benefits of a normal EXO2 are here. So
I have a standard EXO2 conveniently set to the side here, so we can get a nice
visual on the differences. And as you can see, it is about a 40% reduction in
length. It's also a much lighter solution. So for applications that are
space-sensitive, if you wanna hide the sonde, it's a much smaller footprint.
Drone or AUV applications where weight might be a factor, this would be a
better choice. And this is also, you know, much lighter on your budget as well.
So as long as you can supply external power, this is gonna be a more
cost-effective solution than the sonde here. Also, without the internal battery
compartment, you don't have to worry about replacing alkaline batteries. So
it's a more sustainable solution as well.&lt;/p&gt;

&lt;p&gt;So let's talk about the sonde itself. So on the top, we
have the bale and the two main connector ports. We have our power and
communication port here. So this is what would be connected to your topside
monitoring system, which would allow for communication and supplying external
power. We also have our auxiliary port, which you can use to daisy-chain sondes
together. You can connect our EXO PAR sensor or a third-party sensor to it. But
most of the time, I think most users just plug this port here.&lt;/p&gt;

&lt;p&gt;And this is an EXO2, so you get seven sensor ports.
Most of the time, a central wiper will be placed in the center port here
leaving six universal ports to plug in any EXO sensors you want in your payload.
And the central wiper will keep those clean over the course of the deployment.
Also, you can see these four holes here, that is our integrated depth sensor.
So the depth sensor is built into the sonde here. Another cool thing is on the
body of the sonde, it actually tells you how far away the depth measurement is
being made from the other sensor measurements. So, I have a DO sensor here, for
example, I'm gonna plug in.&lt;/p&gt;

&lt;p&gt;So when you're measuring water quality with an EXO,
most of the measurements take place right around this area. All the sensing is
done here. So it's nice that it tells you how far, especially if it's in a
vertical orientation, how far away the depth is being measured versus all the
other sensor readings. And with core software, you can actually input an offset
for the depth sensor if you wanted to kind of match those up if it's deployed
in a vertical orientation. So that's kind of cool. One other thing I wanted to
highlight, and this is true for all of our EXO Sondes, is that we use real wet-mate
connectors. And what that means is if water was on the connector, splashed or
even submerged, ideally, you wouldn't wanna do this, but when you plug a sensor
in, there's no risk to it shorting out or anything like that.&lt;/p&gt;

&lt;p&gt;Some of our competitors that use LEMO-style connectors
with an O-ring seal or a double O-ring seal, that's all well and good but if
water gets in that port and you plug the sensor in, those pins are gonna
corrode. It's not really a factor here. But something that is important about the
wet-mate connectors on the sensor side and on the cable side is keeping them
well lubricated. I actually notice, you might see the pins glistening here, the
wet-mates come pre-lubricated. So that's cool, but you also want to make sure
to periodically apply some of that grease there to keep them well lubricated.
So one other really cool use for this would be using it with a handheld for
spot sampling applications. Go ahead and just plug this in here. All right. So
given this relatively compact form factor and the fact that it has seven sensor
ports, you get all the sensor options available on EXO, again, in a relatively
compact spot sampling package, much more easier to move around and maneuver
than the larger EXO2 Sonde. So EXO2s, definitely consider for spot sampling
applications.&lt;/p&gt;

&lt;p&gt;And with that, that's pretty much all I have to show
you in this video, but if you'd like to learn more, please visit our website at
ysi.com/exo.&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/exo2s-sonde-unboxing-overview"&gt;&lt;img src="http://video.ysi.com/64968560/71980265/04d7d7068a2b3ccf38dfbd2f8aa2fb15/standard/download-8-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=04d7d7068a2b3ccf38dfbd2f8aa2fb15&amp;source=podcast&amp;photo%5fid=71980265" width="625" height="352" type="text/html" medium="video" duration="445" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968560/71980265/04d7d7068a2b3ccf38dfbd2f8aa2fb15/standard/download-8-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968560/71980265/04d7d7068a2b3ccf38dfbd2f8aa2fb15/standard/download-8-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968556/69712510/5c0c67ea26ba0b88a2f734d491943ee0/audio/podcast/69712510-9-audio.mp3" type="audio/mp3" length="1010763"/>
            <title>How to Order | Credit Card</title>
            <link>http://video.ysi.com/how-to-order-credit-card</link>
            <description>&lt;p&gt;How to order on YSI.com and using a credt card.&lt;br&gt;
&lt;p&gt;Add items to your order and continue to checkout.&lt;/p&gt;
&lt;p&gt;At checkout step three, payment, input your card information.&lt;/p&gt;
&lt;p&gt;There are options to save the card to your account and to make the billing address the same as your shipping address.&lt;/p&gt;
&lt;p&gt;If you receive a decline or payment error message, please review and confirm your card information for accuracy.&lt;/p&gt;
&lt;p&gt;Many card errors on checkout are from incorrect billing address and zip code information input by user.&lt;/p&gt;
&lt;p&gt;Once your credit card information is input on step three, continue.&lt;/p&gt;
&lt;p&gt;Review and place your order with the knowledge that your credit card information is safe and secure.&lt;/p&gt;
&lt;p&gt;Please contact &lt;a&gt;orders@ysi.com&lt;/a&gt;, customer service, or live chat, for assistance.&lt;/p&gt;&lt;p&gt;Visit&amp;nbsp;&lt;a href="https://www.ysi.com/how-to-order" target="_blank"&gt;How to Order&lt;/a&gt;&amp;nbsp;for more information.&lt;br&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-order-credit-card"&gt;&lt;img src="http://video.ysi.com/64968556/69712510/5c0c67ea26ba0b88a2f734d491943ee0/standard/download-9-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/69712510</guid>
            <pubDate>Thu, 24 Jun 2021 13:01:24 GMT</pubDate>
            <media:title>How to Order | Credit Card</media:title>
            <itunes:summary>How to order on YSI.com and using a credt card.
Add items to your order and continue to checkout.
At checkout step three, payment, input your card information.
There are options to save the card to your account and to make the billing address the same as your shipping address.
If you receive a decline or payment error message, please review and confirm your card information for accuracy.
Many card errors on checkout are from incorrect billing address and zip code information input by user.
Once your credit card information is input on step three, continue.
Review and place your order with the knowledge that your credit card information is safe and secure.
Please contact orders@ysi.com, customer service, or live chat, for assistance.VisitHow to Orderfor more information.</itunes:summary>
            <itunes:subtitle>How to order on YSI.com and using a credt card.
Add items to your order and continue to checkout.
At checkout step three, payment, input your card information.
There are options to save the card to your account and to make the billing address the...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:24</itunes:duration>
            <media:description type="html">&lt;p&gt;How to order on YSI.com and using a credt card.&lt;br&gt;
&lt;p&gt;Add items to your order and continue to checkout.&lt;/p&gt;
&lt;p&gt;At checkout step three, payment, input your card information.&lt;/p&gt;
&lt;p&gt;There are options to save the card to your account and to make the billing address the same as your shipping address.&lt;/p&gt;
&lt;p&gt;If you receive a decline or payment error message, please review and confirm your card information for accuracy.&lt;/p&gt;
&lt;p&gt;Many card errors on checkout are from incorrect billing address and zip code information input by user.&lt;/p&gt;
&lt;p&gt;Once your credit card information is input on step three, continue.&lt;/p&gt;
&lt;p&gt;Review and place your order with the knowledge that your credit card information is safe and secure.&lt;/p&gt;
&lt;p&gt;Please contact &lt;a&gt;orders@ysi.com&lt;/a&gt;, customer service, or live chat, for assistance.&lt;/p&gt;&lt;p&gt;Visit&amp;nbsp;&lt;a href="https://www.ysi.com/how-to-order" target="_blank"&gt;How to Order&lt;/a&gt;&amp;nbsp;for more information.&lt;br&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-order-credit-card"&gt;&lt;img src="http://video.ysi.com/64968556/69712510/5c0c67ea26ba0b88a2f734d491943ee0/standard/download-9-thumbnail.jpg" width="75" height=""/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=5c0c67ea26ba0b88a2f734d491943ee0&amp;source=podcast&amp;photo%5fid=69712510" width="625" height="352" type="text/html" medium="video" duration="84" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968556/69712510/5c0c67ea26ba0b88a2f734d491943ee0/standard/download-9-thumbnail.jpg" width="75" height=""/>
            <itunes:image href="http://video.ysi.com/64968556/69712510/5c0c67ea26ba0b88a2f734d491943ee0/standard/download-9-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968575/69650396/dd695a094d8d5db34532197d2b3260aa/audio/podcast/69650396-11-audio.mp3" type="audio/mp3" length="780676"/>
            <title>How to Order | Turbo Cart</title>
            <link>http://video.ysi.com/how-to-order-turbo-cart</link>
            <description>&lt;p&gt;How to order on YSI.com using the turbo cart function.&lt;br&gt;&lt;p&gt;Use turbo cart to quickly add items and quantities to your
order. Great for quickly ordering your items from a quote. &lt;/p&gt;

&lt;p&gt;Input your first product SKU number and quantity. You may
add any number of additional SKUs and quantities for items that are available
through e-commerce. &lt;/p&gt;

&lt;p&gt;Recently ordered products can also be added quickly to Turbo
Cart. &lt;/p&gt;

&lt;p&gt;&amp;nbsp;Once your items are
added, proceed to the shopping cart to check out. &lt;/p&gt;

&lt;p&gt;Please contact &lt;a&gt;orders@ysi.com&lt;/a&gt;, customer service, or
live chat, for assistance. &lt;/p&gt;&lt;p&gt;Visit &lt;a href="https://www.ysi.com/how-to-order" target="_blank"&gt;How to Order&lt;/a&gt; for more information.&lt;/p&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-order-turbo-cart"&gt;&lt;img src="http://video.ysi.com/64968575/69650396/dd695a094d8d5db34532197d2b3260aa/standard/download-11-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/69650396</guid>
            <pubDate>Fri, 18 Jun 2021 13:43:32 GMT</pubDate>
            <media:title>How to Order | Turbo Cart</media:title>
            <itunes:summary>How to order on YSI.com using the turbo cart function.Use turbo cart to quickly add items and quantities to your
order. Great for quickly ordering your items from a quote. 

Input your first product SKU number and quantity. You may
add any number of additional SKUs and quantities for items that are available
through e-commerce. 

Recently ordered products can also be added quickly to Turbo
Cart. 

Once your items are
added, proceed to the shopping cart to check out. 

Please contact orders@ysi.com, customer service, or
live chat, for assistance. Visit How to Order for more information.</itunes:summary>
            <itunes:subtitle>How to order on YSI.com using the turbo cart function.Use turbo cart to quickly add items and quantities to your
order. Great for quickly ordering your items from a quote. 

Input your first product SKU number and quantity. You may
add any number...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:05</itunes:duration>
            <media:description type="html">&lt;p&gt;How to order on YSI.com using the turbo cart function.&lt;br&gt;&lt;p&gt;Use turbo cart to quickly add items and quantities to your
order. Great for quickly ordering your items from a quote. &lt;/p&gt;

&lt;p&gt;Input your first product SKU number and quantity. You may
add any number of additional SKUs and quantities for items that are available
through e-commerce. &lt;/p&gt;

&lt;p&gt;Recently ordered products can also be added quickly to Turbo
Cart. &lt;/p&gt;

&lt;p&gt;&amp;nbsp;Once your items are
added, proceed to the shopping cart to check out. &lt;/p&gt;

&lt;p&gt;Please contact &lt;a&gt;orders@ysi.com&lt;/a&gt;, customer service, or
live chat, for assistance. &lt;/p&gt;&lt;p&gt;Visit &lt;a href="https://www.ysi.com/how-to-order" target="_blank"&gt;How to Order&lt;/a&gt; for more information.&lt;/p&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-order-turbo-cart"&gt;&lt;img src="http://video.ysi.com/64968575/69650396/dd695a094d8d5db34532197d2b3260aa/standard/download-11-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=dd695a094d8d5db34532197d2b3260aa&amp;source=podcast&amp;photo%5fid=69650396" width="625" height="352" type="text/html" medium="video" duration="65" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968575/69650396/dd695a094d8d5db34532197d2b3260aa/standard/download-11-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/64968575/69650396/dd695a094d8d5db34532197d2b3260aa/standard/download-11-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968567/69650394/c21a00cb1d122e47101881f082d7dc50/audio/podcast/69650394-7-audio.mp3" type="audio/mp3" length="989447"/>
            <title>How to Order | Tax Exempt Status</title>
            <link>http://video.ysi.com/how-to-order-tax-exempt-status</link>
            <description>&lt;p&gt;How to order on YSI.com and obtaining tax exempt status.&lt;br&gt;&lt;p&gt;First, register your account using the register button at
the top right of the YSI.com website. &lt;/p&gt;

&lt;p&gt;Place your first order. &lt;/p&gt;

&lt;p&gt;Provide your tax exempt document with your order number to &lt;a&gt;orders@ysi.com&lt;/a&gt;.&lt;/p&gt;

&lt;p&gt;Don’t forget to attach your tax exempt document. &lt;/p&gt;

&lt;p&gt;YSI will confirm your tax exempt status, provide email
confirmation of your account’s tax exempt status, and update your order details
to remove the tax. &lt;/p&gt;

&lt;p&gt;Once your customer account is set up as tax exempt, your
orders will remain tax exempt moving forward. &lt;/p&gt;

&lt;p&gt;Please contact &lt;a&gt;orders@ysi.com&lt;/a&gt;, customer service, or
live chat, for assistance. &lt;/p&gt;Visit &lt;a href="https://www.ysi.com/how-to-order"&gt;How to Order&lt;/a&gt; for more information.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-order-tax-exempt-status"&gt;&lt;img src="http://video.ysi.com/64968567/69650394/c21a00cb1d122e47101881f082d7dc50/standard/download-7-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/69650394</guid>
            <pubDate>Fri, 18 Jun 2021 13:43:26 GMT</pubDate>
            <media:title>How to Order | Tax Exempt Status</media:title>
            <itunes:summary>How to order on YSI.com and obtaining tax exempt status.First, register your account using the register button at
the top right of the YSI.com website. 

Place your first order. 

Provide your tax exempt document with your order number to orders@ysi.com.

Don’t forget to attach your tax exempt document. 

YSI will confirm your tax exempt status, provide email
confirmation of your account’s tax exempt status, and update your order details
to remove the tax. 

Once your customer account is set up as tax exempt, your
orders will remain tax exempt moving forward. 

Please contact orders@ysi.com, customer service, or
live chat, for assistance. Visit How to Order for more information.</itunes:summary>
            <itunes:subtitle>How to order on YSI.com and obtaining tax exempt status.First, register your account using the register button at
the top right of the YSI.com website. 

Place your first order. 

Provide your tax exempt document with your order number to...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:22</itunes:duration>
            <media:description type="html">&lt;p&gt;How to order on YSI.com and obtaining tax exempt status.&lt;br&gt;&lt;p&gt;First, register your account using the register button at
the top right of the YSI.com website. &lt;/p&gt;

&lt;p&gt;Place your first order. &lt;/p&gt;

&lt;p&gt;Provide your tax exempt document with your order number to &lt;a&gt;orders@ysi.com&lt;/a&gt;.&lt;/p&gt;

&lt;p&gt;Don’t forget to attach your tax exempt document. &lt;/p&gt;

&lt;p&gt;YSI will confirm your tax exempt status, provide email
confirmation of your account’s tax exempt status, and update your order details
to remove the tax. &lt;/p&gt;

&lt;p&gt;Once your customer account is set up as tax exempt, your
orders will remain tax exempt moving forward. &lt;/p&gt;

&lt;p&gt;Please contact &lt;a&gt;orders@ysi.com&lt;/a&gt;, customer service, or
live chat, for assistance. &lt;/p&gt;Visit &lt;a href="https://www.ysi.com/how-to-order"&gt;How to Order&lt;/a&gt; for more information.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-order-tax-exempt-status"&gt;&lt;img src="http://video.ysi.com/64968567/69650394/c21a00cb1d122e47101881f082d7dc50/standard/download-7-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=c21a00cb1d122e47101881f082d7dc50&amp;source=podcast&amp;photo%5fid=69650394" width="625" height="352" type="text/html" medium="video" duration="82" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968567/69650394/c21a00cb1d122e47101881f082d7dc50/standard/download-7-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/64968567/69650394/c21a00cb1d122e47101881f082d7dc50/standard/download-7-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968577/69650393/db6ccbab16f6903dd2440f2bd0a8cf6c/audio/podcast/69650393-8-audio.mp3" type="audio/mp3" length="1229878"/>
            <title>How to Order | Recurring Orders</title>
            <link>http://video.ysi.com/how-to-order-recurring-orders</link>
            <description>&lt;p&gt;How to order on YSI.com using the recurring orders function.&lt;br&gt;&lt;p&gt;Recurring orders are available from the order confirmation
page, meaning you have to place an order successfully first to make it a
recurring order. &lt;/p&gt;

&lt;p&gt;On order confirmation, select the frequency of your
recurring order. &lt;/p&gt;

&lt;p&gt;Select the starting date. &lt;/p&gt;

&lt;p&gt;Select save as recurring order. &lt;/p&gt;

&lt;p&gt;Recurring orders will replicate your order details for the order
items and quantities, shipping address, and payment. &lt;/p&gt;

&lt;p&gt;If a recurring order is set for a long-term frequency, such
as yearly, please ensure your payment method is kept up to date. &lt;/p&gt;

&lt;p&gt;Recurring orders can be established with either credit card
or purchase order payment methods. &lt;/p&gt;

&lt;p&gt;You can manage recurring orders or cancel at any time from
your account order history. &lt;/p&gt;

&lt;span&gt;Please contact &lt;a&gt;orders@ysi.com&lt;/a&gt;, customer service, or
live chat for assistance.&amp;nbsp;&lt;br&gt;&lt;/span&gt;&lt;br&gt;Visit &lt;a href="https://www.ysi.com/how-to-order" target="_blank"&gt;How to Order&lt;/a&gt; for more information.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-order-recurring-orders"&gt;&lt;img src="http://video.ysi.com/64968577/69650393/db6ccbab16f6903dd2440f2bd0a8cf6c/standard/download-8-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/69650393</guid>
            <pubDate>Fri, 18 Jun 2021 13:43:18 GMT</pubDate>
            <media:title>How to Order | Recurring Orders</media:title>
            <itunes:summary>How to order on YSI.com using the recurring orders function.Recurring orders are available from the order confirmation
page, meaning you have to place an order successfully first to make it a
recurring order. 

On order confirmation, select the frequency of your
recurring order. 

Select the starting date. 

Select save as recurring order. 

Recurring orders will replicate your order details for the order
items and quantities, shipping address, and payment. 

If a recurring order is set for a long-term frequency, such
as yearly, please ensure your payment method is kept up to date. 

Recurring orders can be established with either credit card
or purchase order payment methods. 

You can manage recurring orders or cancel at any time from
your account order history. 

Please contact orders@ysi.com, customer service, or
live chat for assistance.Visit How to Order for more information.</itunes:summary>
            <itunes:subtitle>How to order on YSI.com using the recurring orders function.Recurring orders are available from the order confirmation
page, meaning you have to place an order successfully first to make it a
recurring order. 

On order confirmation, select the...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:42</itunes:duration>
            <media:description type="html">&lt;p&gt;How to order on YSI.com using the recurring orders function.&lt;br&gt;&lt;p&gt;Recurring orders are available from the order confirmation
page, meaning you have to place an order successfully first to make it a
recurring order. &lt;/p&gt;

&lt;p&gt;On order confirmation, select the frequency of your
recurring order. &lt;/p&gt;

&lt;p&gt;Select the starting date. &lt;/p&gt;

&lt;p&gt;Select save as recurring order. &lt;/p&gt;

&lt;p&gt;Recurring orders will replicate your order details for the order
items and quantities, shipping address, and payment. &lt;/p&gt;

&lt;p&gt;If a recurring order is set for a long-term frequency, such
as yearly, please ensure your payment method is kept up to date. &lt;/p&gt;

&lt;p&gt;Recurring orders can be established with either credit card
or purchase order payment methods. &lt;/p&gt;

&lt;p&gt;You can manage recurring orders or cancel at any time from
your account order history. &lt;/p&gt;

&lt;span&gt;Please contact &lt;a&gt;orders@ysi.com&lt;/a&gt;, customer service, or
live chat for assistance.&amp;nbsp;&lt;br&gt;&lt;/span&gt;&lt;br&gt;Visit &lt;a href="https://www.ysi.com/how-to-order" target="_blank"&gt;How to Order&lt;/a&gt; for more information.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-order-recurring-orders"&gt;&lt;img src="http://video.ysi.com/64968577/69650393/db6ccbab16f6903dd2440f2bd0a8cf6c/standard/download-8-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=db6ccbab16f6903dd2440f2bd0a8cf6c&amp;source=podcast&amp;photo%5fid=69650393" width="625" height="352" type="text/html" medium="video" duration="102" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968577/69650393/db6ccbab16f6903dd2440f2bd0a8cf6c/standard/download-8-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/64968577/69650393/db6ccbab16f6903dd2440f2bd0a8cf6c/standard/download-8-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968580/69650392/4026d35141757f2642df2c1914cb6670/audio/podcast/69650392-7-audio.mp3" type="audio/mp3" length="1496954"/>
            <title>How to Order | Purchase Orders</title>
            <link>http://video.ysi.com/how-to-order-purchase-orders</link>
            <description>&lt;p&gt;&lt;p&gt;How to Order on YSI.com while using a purchase order.&lt;/p&gt;&lt;p&gt;Purchase orders are a payment option at step three of
checkout.&amp;nbsp;&lt;br&gt;&lt;/p&gt;

&lt;p&gt;Send an email to customer service at &lt;a&gt;orders@ysi.com&lt;/a&gt;
requesting that purchase orders be enabled for your account. &lt;/p&gt;

&lt;p&gt;New customers with no credit standing with YSI &amp;nbsp;will need to Submit a Credit
Application to Customer Service with their PO request email. &lt;/p&gt;

&lt;p&gt;Don’t forget to attach the credit application.&lt;/p&gt;

&lt;p&gt;Upon email receipt, YSI will confirm your credit status, match
your customer account to the organization and provide email confirmation that
POs are enabled for your customer account.&lt;/p&gt;

&lt;p&gt;Once your customer account is set up for POs, you will be
able to select your approved billing addresses as your payment on checkout.&lt;/p&gt;

&lt;p&gt;After logging in, adding items to your order, and continuing
to checkout, on checkout step three – Payment – select Purchase Order. &lt;/p&gt;

&lt;p&gt;Input your purchase order number. &lt;/p&gt;

&lt;p&gt;Select and acknowledge that you are authorized to make the
purchase.&amp;nbsp; &lt;/p&gt;

&lt;p&gt;Select your bill-to address for payment and continue placing
your order. &lt;/p&gt;

&lt;p&gt;Contact customer service for any billing address questions
or additions.&amp;nbsp; &lt;/p&gt;

&lt;p&gt;More information is also available on your shopping cart page
and the how to order page. &lt;/p&gt;

&lt;span&gt;For all other questions, contact &lt;a&gt;orders@ysi.com&lt;/a&gt;,
customer service, or live chat, for assistance.&lt;br&gt;&lt;br&gt;Visit &lt;a href="https://www.ysi.com/how-to-order" target="_blank"&gt;How to Order&lt;/a&gt; for more information.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-order-purchase-orders"&gt;&lt;img src="http://video.ysi.com/64968580/69650392/4026d35141757f2642df2c1914cb6670/standard/download-7-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/69650392</guid>
            <pubDate>Fri, 18 Jun 2021 13:43:09 GMT</pubDate>
            <media:title>How to Order | Purchase Orders</media:title>
            <itunes:summary>How to Order on YSI.com while using a purchase order.Purchase orders are a payment option at step three of
checkout.

Send an email to customer service at orders@ysi.com
requesting that purchase orders be enabled for your account. 

New customers with no credit standing with YSI will need to Submit a Credit
Application to Customer Service with their PO request email. 

Don’t forget to attach the credit application.

Upon email receipt, YSI will confirm your credit status, match
your customer account to the organization and provide email confirmation that
POs are enabled for your customer account.

Once your customer account is set up for POs, you will be
able to select your approved billing addresses as your payment on checkout.

After logging in, adding items to your order, and continuing
to checkout, on checkout step three – Payment – select Purchase Order. 

Input your purchase order number. 

Select and acknowledge that you are authorized to make the
purchase. 

Select your bill-to address for payment and continue placing
your order. 

Contact customer service for any billing address questions
or additions. 

More information is also available on your shopping cart page
and the how to order page. 

For all other questions, contact orders@ysi.com,
customer service, or live chat, for assistance.Visit How to Order for more information.</itunes:summary>
            <itunes:subtitle>How to Order on YSI.com while using a purchase order.Purchase orders are a payment option at step three of
checkout.

Send an email to customer service at orders@ysi.com
requesting that purchase orders be enabled for your account. 

New customers...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>02:05</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;How to Order on YSI.com while using a purchase order.&lt;/p&gt;&lt;p&gt;Purchase orders are a payment option at step three of
checkout.&amp;nbsp;&lt;br&gt;&lt;/p&gt;

&lt;p&gt;Send an email to customer service at &lt;a&gt;orders@ysi.com&lt;/a&gt;
requesting that purchase orders be enabled for your account. &lt;/p&gt;

&lt;p&gt;New customers with no credit standing with YSI &amp;nbsp;will need to Submit a Credit
Application to Customer Service with their PO request email. &lt;/p&gt;

&lt;p&gt;Don’t forget to attach the credit application.&lt;/p&gt;

&lt;p&gt;Upon email receipt, YSI will confirm your credit status, match
your customer account to the organization and provide email confirmation that
POs are enabled for your customer account.&lt;/p&gt;

&lt;p&gt;Once your customer account is set up for POs, you will be
able to select your approved billing addresses as your payment on checkout.&lt;/p&gt;

&lt;p&gt;After logging in, adding items to your order, and continuing
to checkout, on checkout step three – Payment – select Purchase Order. &lt;/p&gt;

&lt;p&gt;Input your purchase order number. &lt;/p&gt;

&lt;p&gt;Select and acknowledge that you are authorized to make the
purchase.&amp;nbsp; &lt;/p&gt;

&lt;p&gt;Select your bill-to address for payment and continue placing
your order. &lt;/p&gt;

&lt;p&gt;Contact customer service for any billing address questions
or additions.&amp;nbsp; &lt;/p&gt;

&lt;p&gt;More information is also available on your shopping cart page
and the how to order page. &lt;/p&gt;

&lt;span&gt;For all other questions, contact &lt;a&gt;orders@ysi.com&lt;/a&gt;,
customer service, or live chat, for assistance.&lt;br&gt;&lt;br&gt;Visit &lt;a href="https://www.ysi.com/how-to-order" target="_blank"&gt;How to Order&lt;/a&gt; for more information.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-order-purchase-orders"&gt;&lt;img src="http://video.ysi.com/64968580/69650392/4026d35141757f2642df2c1914cb6670/standard/download-7-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=4026d35141757f2642df2c1914cb6670&amp;source=podcast&amp;photo%5fid=69650392" width="625" height="352" type="text/html" medium="video" duration="125" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968580/69650392/4026d35141757f2642df2c1914cb6670/standard/download-7-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/64968580/69650392/4026d35141757f2642df2c1914cb6670/standard/download-7-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968579/68075492/8408331d03444cb577f2c2c7f397a2a0/audio/podcast/68075492-2-audio.mp3" type="audio/mp3" length="3180284"/>
            <title>Aanderaa Oxygen Sensor One-Point Calibration</title>
            <link>http://video.ysi.com/aanderaa-oxygen-sensor-one-point</link>
            <description>&lt;p&gt;Learn how to calibrate your &lt;a href="https://www.aanderaa.com/oxygen-sensors"&gt;Aanderaa Oxygen Sensor&lt;/a&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/aanderaa-oxygen-sensor-one-point"&gt;&lt;img src="http://video.ysi.com/64968579/68075492/8408331d03444cb577f2c2c7f397a2a0/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/68075492</guid>
            <pubDate>Tue, 06 Apr 2021 08:39:51 GMT</pubDate>
            <media:title>Aanderaa Oxygen Sensor One-Point Calibration</media:title>
            <itunes:summary>Learn how to calibrate your Aanderaa Oxygen Sensor</itunes:summary>
            <itunes:subtitle>Learn how to calibrate your Aanderaa Oxygen Sensor</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>04:25</itunes:duration>
            <media:description type="html">&lt;p&gt;Learn how to calibrate your &lt;a href="https://www.aanderaa.com/oxygen-sensors"&gt;Aanderaa Oxygen Sensor&lt;/a&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/aanderaa-oxygen-sensor-one-point"&gt;&lt;img src="http://video.ysi.com/64968579/68075492/8408331d03444cb577f2c2c7f397a2a0/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=8408331d03444cb577f2c2c7f397a2a0&amp;source=podcast&amp;photo%5fid=68075492" width="625" height="352" type="text/html" medium="video" duration="265" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968579/68075492/8408331d03444cb577f2c2c7f397a2a0/standard/download-2-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/64968579/68075492/8408331d03444cb577f2c2c7f397a2a0/standard/download-2-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968576/67530183/53a9b07896b9f164e22b63dd2dd540ca/audio/podcast/67530183-4-audio.mp3" type="audio/mp3" length="5413754"/>
            <title>3017M DPD Chlorine Analyzer - Maintenance, Reagents and Tubing Replacement</title>
            <link>http://video.ysi.com/3017m-dpd-chlorine-analyzer-2</link>
            <description>&lt;p&gt;This video covers maintenance, reagents and tubing replacement for YSI's new &lt;a href="https://www.ysi.com/3017m"&gt;3017M Chlorine Analyzer.&lt;/a&gt; This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA-approved method.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/3017m-dpd-chlorine-analyzer-2"&gt;&lt;img src="http://video.ysi.com/64968576/67530183/53a9b07896b9f164e22b63dd2dd540ca/standard/download-4-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/67530183</guid>
            <pubDate>Thu, 04 Mar 2021 11:23:23 GMT</pubDate>
            <media:title>3017M DPD Chlorine Analyzer - Maintenance, Reagents and Tubing Replacement</media:title>
            <itunes:summary>This video covers maintenance, reagents and tubing replacement for YSI's new 3017M Chlorine Analyzer. This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA-approved method.</itunes:summary>
            <itunes:subtitle>This video covers maintenance, reagents and tubing replacement for YSI's new 3017M Chlorine Analyzer. This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>07:31</itunes:duration>
            <media:description type="html">&lt;p&gt;This video covers maintenance, reagents and tubing replacement for YSI's new &lt;a href="https://www.ysi.com/3017m"&gt;3017M Chlorine Analyzer.&lt;/a&gt; This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA-approved method.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/3017m-dpd-chlorine-analyzer-2"&gt;&lt;img src="http://video.ysi.com/64968576/67530183/53a9b07896b9f164e22b63dd2dd540ca/standard/download-4-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=53a9b07896b9f164e22b63dd2dd540ca&amp;source=podcast&amp;photo%5fid=67530183" width="625" height="352" type="text/html" medium="video" duration="451" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968576/67530183/53a9b07896b9f164e22b63dd2dd540ca/standard/download-4-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/64968576/67530183/53a9b07896b9f164e22b63dd2dd540ca/standard/download-4-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968580/67529825/623399a14252dc6f58da4decfb538e0e/audio/podcast/67529825-7-audio.mp3" type="audio/mp3" length="2710394"/>
            <title>3017M DPD Chlorine Analyzer - Startup and Installation</title>
            <link>http://video.ysi.com/3017m-dpd-chlorine-analyzer-1</link>
            <description>&lt;p&gt;Learn about startup and installation of YSI's &lt;a href="https://www.ysi.com/3017m"&gt;3017M Chlorine Analyzer&lt;/a&gt;. This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA-approved method.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/3017m-dpd-chlorine-analyzer-1"&gt;&lt;img src="http://video.ysi.com/64968580/67529825/623399a14252dc6f58da4decfb538e0e/standard/download-7-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/67529825</guid>
            <pubDate>Thu, 04 Mar 2021 11:10:24 GMT</pubDate>
            <media:title>3017M DPD Chlorine Analyzer - Startup and Installation</media:title>
            <itunes:summary>Learn about startup and installation of YSI's 3017M Chlorine Analyzer. This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA-approved method.</itunes:summary>
            <itunes:subtitle>Learn about startup and installation of YSI's 3017M Chlorine Analyzer. This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA-approved method.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>03:46</itunes:duration>
            <media:description type="html">&lt;p&gt;Learn about startup and installation of YSI's &lt;a href="https://www.ysi.com/3017m"&gt;3017M Chlorine Analyzer&lt;/a&gt;. This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA-approved method.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/3017m-dpd-chlorine-analyzer-1"&gt;&lt;img src="http://video.ysi.com/64968580/67529825/623399a14252dc6f58da4decfb538e0e/standard/download-7-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=623399a14252dc6f58da4decfb538e0e&amp;source=podcast&amp;photo%5fid=67529825" width="625" height="352" type="text/html" medium="video" duration="226" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968580/67529825/623399a14252dc6f58da4decfb538e0e/standard/download-7-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/64968580/67529825/623399a14252dc6f58da4decfb538e0e/standard/download-7-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968555/67529338/f757706533a2a743a990fbf6fac7f870/audio/podcast/67529338-3-audio.mp3" type="audio/mp3" length="1915749"/>
            <title>3017M DPD Chlorine Analyzer Introduction - Overview - Operation</title>
            <link>http://video.ysi.com/3017m-dpd-chlorine-analyzer</link>
            <description>&lt;p&gt;This video is an introduction to YSI's new &lt;a href="https://www.ysi.com/3017m"&gt;3017M Chlorine Analyzer&lt;/a&gt;. This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA-approved method.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/3017m-dpd-chlorine-analyzer"&gt;&lt;img src="http://video.ysi.com/64968555/67529338/f757706533a2a743a990fbf6fac7f870/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/67529338</guid>
            <pubDate>Thu, 04 Mar 2021 10:26:11 GMT</pubDate>
            <media:title>3017M DPD Chlorine Analyzer Introduction - Overview - Operation</media:title>
            <itunes:summary>This video is an introduction to YSI's new 3017M Chlorine Analyzer. This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA-approved method.</itunes:summary>
            <itunes:subtitle>This video is an introduction to YSI's new 3017M Chlorine Analyzer. This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA-approved method.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>02:40</itunes:duration>
            <media:description type="html">&lt;p&gt;This video is an introduction to YSI's new &lt;a href="https://www.ysi.com/3017m"&gt;3017M Chlorine Analyzer&lt;/a&gt;. This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA-approved method.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/3017m-dpd-chlorine-analyzer"&gt;&lt;img src="http://video.ysi.com/64968555/67529338/f757706533a2a743a990fbf6fac7f870/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=f757706533a2a743a990fbf6fac7f870&amp;source=podcast&amp;photo%5fid=67529338" width="625" height="352" type="text/html" medium="video" duration="160" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968555/67529338/f757706533a2a743a990fbf6fac7f870/standard/download-3-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/64968555/67529338/f757706533a2a743a990fbf6fac7f870/standard/download-3-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968556/67364580/f0460b45af58b713b19d93f1f5155ff6/audio/podcast/67364580-2-audio.mp3" type="audio/mp3" length="614554"/>
            <title>IQ SensorNet How-To | IQ Web Connect Overview</title>
            <link>http://video.ysi.com/iq-sensornet-how-to-iq-web-connect</link>
            <description>&lt;p&gt;IQ Web Connect allows you to conveniently access &lt;a href="https://www.ysi.com/iqsn"&gt;IQ SensorNet&lt;/a&gt; remotely from a computer, tablet, or mobile phone. Turn any mobile device or computer with internet access into a virtual IQ SensorNet controller with the ability to view and download data, modify settings on your controller, or save your configuration from remote locations.
&lt;p&gt;Simply connect your IQ SensorNet system to the internet via a local network using the integrated Ethernet interface to access IQ Web Connect. This feature is included with IQ SensorNet and is free with no monthly fee or contract.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-how-to-iq-web-connect"&gt;&lt;img src="http://video.ysi.com/64968556/67364580/f0460b45af58b713b19d93f1f5155ff6/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/67364580</guid>
            <pubDate>Thu, 25 Feb 2021 13:44:15 GMT</pubDate>
            <media:title>IQ SensorNet How-To | IQ Web Connect Overview</media:title>
            <itunes:summary>IQ Web Connect allows you to conveniently access IQ SensorNet remotely from a computer, tablet, or mobile phone. Turn any mobile device or computer with internet access into a virtual IQ SensorNet controller with the ability to view and download data, modify settings on your controller, or save your configuration from remote locations.
Simply connect your IQ SensorNet system to the internet via a local network using the integrated Ethernet interface to access IQ Web Connect. This feature is included with IQ SensorNet and is free with no monthly fee or contract.</itunes:summary>
            <itunes:subtitle>IQ Web Connect allows you to conveniently access IQ SensorNet remotely from a computer, tablet, or mobile phone. Turn any mobile device or computer with internet access into a virtual IQ SensorNet controller with the ability to view and download...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>00:51</itunes:duration>
            <media:description type="html">&lt;p&gt;IQ Web Connect allows you to conveniently access &lt;a href="https://www.ysi.com/iqsn"&gt;IQ SensorNet&lt;/a&gt; remotely from a computer, tablet, or mobile phone. Turn any mobile device or computer with internet access into a virtual IQ SensorNet controller with the ability to view and download data, modify settings on your controller, or save your configuration from remote locations.
&lt;p&gt;Simply connect your IQ SensorNet system to the internet via a local network using the integrated Ethernet interface to access IQ Web Connect. This feature is included with IQ SensorNet and is free with no monthly fee or contract.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/iq-sensornet-how-to-iq-web-connect"&gt;&lt;img src="http://video.ysi.com/64968556/67364580/f0460b45af58b713b19d93f1f5155ff6/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=f0460b45af58b713b19d93f1f5155ff6&amp;source=podcast&amp;photo%5fid=67364580" width="625" height="352" type="text/html" medium="video" duration="51" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968556/67364580/f0460b45af58b713b19d93f1f5155ff6/standard/download-2-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/64968556/67364580/f0460b45af58b713b19d93f1f5155ff6/standard/download-2-thumbnail.jpg/thumbnail.jpg"/>
            <category>iq sensornet</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968570/66518729/19662344a8dab03d60d404b3b4fc982b/audio/podcast/66518729-2-audio.mp3" type="audio/mp3" length="5625032"/>
            <title>Aanderaa Oxygen Sensor: Foil Change</title>
            <link>http://video.ysi.com/aanderaa-oxygen-sensor-foil-change</link>
            <description>&lt;p&gt;Learn how to conduct a foil change of the &lt;a href="https://www.aanderaa.com/oxygen-sensors"&gt;Aanderaa Oxygen &lt;/a&gt;Sensor as well as how to implement the new coefficients to the foil using the Real-Time Collector&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/aanderaa-oxygen-sensor-foil-change"&gt;&lt;img src="http://video.ysi.com/64968570/66518729/19662344a8dab03d60d404b3b4fc982b/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/66518729</guid>
            <pubDate>Thu, 11 Feb 2021 10:50:11 GMT</pubDate>
            <media:title>Aanderaa Oxygen Sensor: Foil Change</media:title>
            <itunes:summary>Learn how to conduct a foil change of the Aanderaa Oxygen Sensor as well as how to implement the new coefficients to the foil using the Real-Time Collector</itunes:summary>
            <itunes:subtitle>Learn how to conduct a foil change of the Aanderaa Oxygen Sensor as well as how to implement the new coefficients to the foil using the Real-Time Collector</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>07:49</itunes:duration>
            <media:description type="html">&lt;p&gt;Learn how to conduct a foil change of the &lt;a href="https://www.aanderaa.com/oxygen-sensors"&gt;Aanderaa Oxygen &lt;/a&gt;Sensor as well as how to implement the new coefficients to the foil using the Real-Time Collector&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/aanderaa-oxygen-sensor-foil-change"&gt;&lt;img src="http://video.ysi.com/64968570/66518729/19662344a8dab03d60d404b3b4fc982b/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=19662344a8dab03d60d404b3b4fc982b&amp;source=podcast&amp;photo%5fid=66518729" width="625" height="352" type="text/html" medium="video" duration="469" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968570/66518729/19662344a8dab03d60d404b3b4fc982b/standard/download-2-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/64968570/66518729/19662344a8dab03d60d404b3b4fc982b/standard/download-2-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/64968559/66831054/bb3de666b4dbcc76fd30041fd5bcf60b/audio/podcast/66831054-51-audio.mp3" type="audio/mp3" length="750583"/>
            <title>Global Water Flow Probe Overview</title>
            <link>http://video.ysi.com/global-water-flow-probe-overview</link>
            <description>&lt;p&gt;A brief demonstration of how to use the Global Water flow probe.&lt;br&gt;&lt;br&gt;Designed for stormwater runoff studies, sewer flow measurements, measuring flows in rivers and streams, and monitoring water velocity in ditches and canals, Flow Probe is ideal in hydrological flow measurements in the field.&lt;br&gt;&lt;br&gt;Learn more about the Flow Probe: &lt;a href="https://www.ysi.com/flow-probe"&gt;YSI.com/flow-probe&lt;/a&gt;&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/global-water-flow-probe-overview"&gt;&lt;img src="http://video.ysi.com/64968559/66831054/bb3de666b4dbcc76fd30041fd5bcf60b/standard/download-51-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/66831054</guid>
            <pubDate>Wed, 03 Feb 2021 09:41:11 GMT</pubDate>
            <media:title>Global Water Flow Probe Overview</media:title>
            <itunes:summary>A brief demonstration of how to use the Global Water flow probe.Designed for stormwater runoff studies, sewer flow measurements, measuring flows in rivers and streams, and monitoring water velocity in ditches and canals, Flow Probe is ideal in hydrological flow measurements in the field.Learn more about the Flow Probe: YSI.com/flow-probe</itunes:summary>
            <itunes:subtitle>A brief demonstration of how to use the Global Water flow probe.Designed for stormwater runoff studies, sewer flow measurements, measuring flows in rivers and streams, and monitoring water velocity in ditches and canals, Flow Probe is ideal in...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:02</itunes:duration>
            <media:description type="html">&lt;p&gt;A brief demonstration of how to use the Global Water flow probe.&lt;br&gt;&lt;br&gt;Designed for stormwater runoff studies, sewer flow measurements, measuring flows in rivers and streams, and monitoring water velocity in ditches and canals, Flow Probe is ideal in hydrological flow measurements in the field.&lt;br&gt;&lt;br&gt;Learn more about the Flow Probe: &lt;a href="https://www.ysi.com/flow-probe"&gt;YSI.com/flow-probe&lt;/a&gt;&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/global-water-flow-probe-overview"&gt;&lt;img src="http://video.ysi.com/64968559/66831054/bb3de666b4dbcc76fd30041fd5bcf60b/standard/download-51-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=bb3de666b4dbcc76fd30041fd5bcf60b&amp;source=podcast&amp;photo%5fid=66831054" width="625" height="352" type="text/html" medium="video" duration="62" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968559/66831054/bb3de666b4dbcc76fd30041fd5bcf60b/standard/download-51-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/64968559/66831054/bb3de666b4dbcc76fd30041fd5bcf60b/standard/download-51-thumbnail.jpg/thumbnail.jpg"/>
            <category>flow measurement</category>
            <category>flow probe</category>
            <category>global water</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/60445028/64778649/00af911e16cd2c0f59124ec277d2b0a2/audio/podcast/64778649-2-audio.mp3" type="audio/mp3" length="1533368"/>
            <title>Aanderaa Oxygen Sensor Cleaning Procedure</title>
            <link>http://video.ysi.com/aanderaa-oxygen-sensor-cleaning</link>
            <description>&lt;p&gt;&lt;div&gt;Learn how to clean your &lt;a href="https://www.aanderaa.com/oxygen-sensors"&gt;Aanderaa Oxygen &lt;/a&gt;Sensor. You will also gain knowledge on how to check and change the foil. &lt;/div&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/aanderaa-oxygen-sensor-cleaning"&gt;&lt;img src="http://video.ysi.com/60445028/64778649/00af911e16cd2c0f59124ec277d2b0a2/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/64778649</guid>
            <pubDate>Wed, 21 Oct 2020 07:52:13 GMT</pubDate>
            <media:title>Aanderaa Oxygen Sensor Cleaning Procedure</media:title>
            <itunes:summary>Learn how to clean your Aanderaa Oxygen Sensor. You will also gain knowledge on how to check and change the foil. </itunes:summary>
            <itunes:subtitle>Learn how to clean your Aanderaa Oxygen Sensor. You will also gain knowledge on how to check and change the foil. </itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>04:15</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;div&gt;Learn how to clean your &lt;a href="https://www.aanderaa.com/oxygen-sensors"&gt;Aanderaa Oxygen &lt;/a&gt;Sensor. You will also gain knowledge on how to check and change the foil. &lt;/div&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/aanderaa-oxygen-sensor-cleaning"&gt;&lt;img src="http://video.ysi.com/60445028/64778649/00af911e16cd2c0f59124ec277d2b0a2/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=00af911e16cd2c0f59124ec277d2b0a2&amp;source=podcast&amp;photo%5fid=64778649" width="625" height="352" type="text/html" medium="video" duration="255" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/60445028/64778649/00af911e16cd2c0f59124ec277d2b0a2/standard/download-2-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/60445028/64778649/00af911e16cd2c0f59124ec277d2b0a2/standard/download-2-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/60650860/64385368/78528b3b45715ad42b618a6873d9a4c3/audio/podcast/64385368-3-audio.mp3" type="audio/mp3" length="3369985"/>
            <title>YSI 2900 Performing a Preventative Maintenance (PM) Inspection</title>
            <link>http://video.ysi.com/ysi-2900-performing-a-preventative</link>
            <description>&lt;p&gt;Regular six-month preventative maintenance checks are essential for the functional operation of the analyzer and are helpful in maximizing your laboratory’s investment.  This video provides an explanation for how to complete a full PM inspection on the &lt;a href="https://www.ysi.com/ysi-2900-nutrient-biochemistry-analyzer" target="_blank"&gt;YSI 2900 Biochemistry Analyzer&lt;/a&gt;.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-2900-performing-a-preventative"&gt;&lt;img src="http://video.ysi.com/60650860/64385368/78528b3b45715ad42b618a6873d9a4c3/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/64385368</guid>
            <pubDate>Thu, 24 Sep 2020 08:17:56 GMT</pubDate>
            <media:title>YSI 2900 Performing a Preventative Maintenance (PM) Inspection</media:title>
            <itunes:summary>Regular six-month preventative maintenance checks are essential for the functional operation of the analyzer and are helpful in maximizing your laboratory’s investment.  This video provides an explanation for how to complete a full PM inspection on the YSI 2900 Biochemistry Analyzer.</itunes:summary>
            <itunes:subtitle>Regular six-month preventative maintenance checks are essential for the functional operation of the analyzer and are helpful in maximizing your laboratory’s investment.  This video provides an explanation for how to complete a full PM inspection...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>09:22</itunes:duration>
            <media:description type="html">&lt;p&gt;Regular six-month preventative maintenance checks are essential for the functional operation of the analyzer and are helpful in maximizing your laboratory’s investment.  This video provides an explanation for how to complete a full PM inspection on the &lt;a href="https://www.ysi.com/ysi-2900-nutrient-biochemistry-analyzer" target="_blank"&gt;YSI 2900 Biochemistry Analyzer&lt;/a&gt;.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-2900-performing-a-preventative"&gt;&lt;img src="http://video.ysi.com/60650860/64385368/78528b3b45715ad42b618a6873d9a4c3/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=78528b3b45715ad42b618a6873d9a4c3&amp;source=podcast&amp;photo%5fid=64385368" width="625" height="352" type="text/html" medium="video" duration="562" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/60650860/64385368/78528b3b45715ad42b618a6873d9a4c3/standard/download-3-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/60650860/64385368/78528b3b45715ad42b618a6873d9a4c3/standard/download-3-thumbnail.jpg/thumbnail.jpg"/>
            <category>biochemistry analyzer</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/60650857/64385055/cce9ab4a73c90d1a8e45892e24aaa55c/audio/podcast/64385055-2-audio.mp3" type="audio/mp3" length="639667"/>
            <title>YSI 2900 Changing Membranes</title>
            <link>http://video.ysi.com/ysi-2900-changing-membranes</link>
            <description>&lt;p&gt;This help video demonstrates how to change membranes if there are existing membranes on the probes and how to place membranes for the first time on the &lt;a href="https://www.ysi.com/ysi-2900-nutrient-biochemistry-analyzer" target="_blank"&gt;YSI 2900 Biochemistry Analyzer&lt;/a&gt;.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-2900-changing-membranes"&gt;&lt;img src="http://video.ysi.com/60650857/64385055/cce9ab4a73c90d1a8e45892e24aaa55c/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/64385055</guid>
            <pubDate>Thu, 24 Sep 2020 08:17:49 GMT</pubDate>
            <media:title>YSI 2900 Changing Membranes</media:title>
            <itunes:summary>This help video demonstrates how to change membranes if there are existing membranes on the probes and how to place membranes for the first time on the YSI 2900 Biochemistry Analyzer.</itunes:summary>
            <itunes:subtitle>This help video demonstrates how to change membranes if there are existing membranes on the probes and how to place membranes for the first time on the YSI 2900 Biochemistry Analyzer.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:46</itunes:duration>
            <media:description type="html">&lt;p&gt;This help video demonstrates how to change membranes if there are existing membranes on the probes and how to place membranes for the first time on the &lt;a href="https://www.ysi.com/ysi-2900-nutrient-biochemistry-analyzer" target="_blank"&gt;YSI 2900 Biochemistry Analyzer&lt;/a&gt;.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-2900-changing-membranes"&gt;&lt;img src="http://video.ysi.com/60650857/64385055/cce9ab4a73c90d1a8e45892e24aaa55c/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=cce9ab4a73c90d1a8e45892e24aaa55c&amp;source=podcast&amp;photo%5fid=64385055" width="625" height="352" type="text/html" medium="video" duration="106" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/60650857/64385055/cce9ab4a73c90d1a8e45892e24aaa55c/standard/download-2-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/60650857/64385055/cce9ab4a73c90d1a8e45892e24aaa55c/standard/download-2-thumbnail.jpg/thumbnail.jpg"/>
            <category>biochemistry analyzer</category>
            <category>laboratory</category>
            <category>life sciences</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/60650858/64384981/ad3cfe490c1738f56da0c5e13b7c4c23/audio/podcast/64384981-3-audio.mp3" type="audio/mp3" length="411147"/>
            <title>YSI 2900 Calibrating the Instrument</title>
            <link>http://video.ysi.com/ysi-2900-calibrating-the-instrument</link>
            <description>&lt;p&gt;This help video demonstrates how to properly calibrate the &lt;a href="https://www.ysi.com/ysi-2900-nutrient-biochemistry-analyzer" target="_blank"&gt;YSI 2900 Biochemistry Analyzer&lt;/a&gt;.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-2900-calibrating-the-instrument"&gt;&lt;img src="http://video.ysi.com/60650858/64384981/ad3cfe490c1738f56da0c5e13b7c4c23/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/64384981</guid>
            <pubDate>Thu, 24 Sep 2020 08:17:41 GMT</pubDate>
            <media:title>YSI 2900 Calibrating the Instrument</media:title>
            <itunes:summary>This help video demonstrates how to properly calibrate the YSI 2900 Biochemistry Analyzer.</itunes:summary>
            <itunes:subtitle>This help video demonstrates how to properly calibrate the YSI 2900 Biochemistry Analyzer.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:08</itunes:duration>
            <media:description type="html">&lt;p&gt;This help video demonstrates how to properly calibrate the &lt;a href="https://www.ysi.com/ysi-2900-nutrient-biochemistry-analyzer" target="_blank"&gt;YSI 2900 Biochemistry Analyzer&lt;/a&gt;.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-2900-calibrating-the-instrument"&gt;&lt;img src="http://video.ysi.com/60650858/64384981/ad3cfe490c1738f56da0c5e13b7c4c23/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=ad3cfe490c1738f56da0c5e13b7c4c23&amp;source=podcast&amp;photo%5fid=64384981" width="625" height="352" type="text/html" medium="video" duration="68" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/60650858/64384981/ad3cfe490c1738f56da0c5e13b7c4c23/standard/download-3-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/60650858/64384981/ad3cfe490c1738f56da0c5e13b7c4c23/standard/download-3-thumbnail.jpg/thumbnail.jpg"/>
            <category>biochemistry</category>
            <category>biochemistry analyzer</category>
            <category>lab</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/60445028/63723352/d7f8350e0fe0a0667ccacc2ae88d7a4c/audio/podcast/63723352-3-audio.mp3" type="audio/mp3" length="3138801"/>
            <title>How to Create a Method in TOCView</title>
            <link>http://video.ysi.com/how-to-create-a-method-in-tocview</link>
            <description>&lt;p&gt;This video provides step-by-step instruction on how to properly create a method in TOCView for TOC analysis.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-create-a-method-in-tocview"&gt;&lt;img src="http://video.ysi.com/60445028/63723352/d7f8350e0fe0a0667ccacc2ae88d7a4c/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/63723352</guid>
            <pubDate>Mon, 31 Aug 2020 14:52:08 GMT</pubDate>
            <media:title>How to Create a Method in TOCView</media:title>
            <itunes:summary>This video provides step-by-step instruction on how to properly create a method in TOCView for TOC analysis.</itunes:summary>
            <itunes:subtitle>This video provides step-by-step instruction on how to properly create a method in TOCView for TOC analysis.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>08:43</itunes:duration>
            <media:description type="html">&lt;p&gt;This video provides step-by-step instruction on how to properly create a method in TOCView for TOC analysis.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-create-a-method-in-tocview"&gt;&lt;img src="http://video.ysi.com/60445028/63723352/d7f8350e0fe0a0667ccacc2ae88d7a4c/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=d7f8350e0fe0a0667ccacc2ae88d7a4c&amp;source=podcast&amp;photo%5fid=63723352" width="625" height="352" type="text/html" medium="video" duration="523" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/60445028/63723352/d7f8350e0fe0a0667ccacc2ae88d7a4c/standard/download-3-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/60445028/63723352/d7f8350e0fe0a0667ccacc2ae88d7a4c/standard/download-3-thumbnail.jpg/thumbnail.jpg"/>
            <category>toc analysis</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/60445188/63723354/58f1c9445b5df8159db79b3d66de1c7f/audio/podcast/63723354-3-audio.mp3" type="audio/mp3" length="1375379"/>
            <title>How to Create a Sequence in TOCView</title>
            <link>http://video.ysi.com/how-to-create-a-sequence-in-tocview</link>
            <description>&lt;p&gt;This video provides step-by-step instructions on how to properly create a sequence in TOCView.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-create-a-sequence-in-tocview"&gt;&lt;img src="http://video.ysi.com/60445188/63723354/58f1c9445b5df8159db79b3d66de1c7f/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/63723354</guid>
            <pubDate>Mon, 31 Aug 2020 14:50:49 GMT</pubDate>
            <media:title>How to Create a Sequence in TOCView</media:title>
            <itunes:summary>This video provides step-by-step instructions on how to properly create a sequence in TOCView.</itunes:summary>
            <itunes:subtitle>This video provides step-by-step instructions on how to properly create a sequence in TOCView.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>03:49</itunes:duration>
            <media:description type="html">&lt;p&gt;This video provides step-by-step instructions on how to properly create a sequence in TOCView.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-create-a-sequence-in-tocview"&gt;&lt;img src="http://video.ysi.com/60445188/63723354/58f1c9445b5df8159db79b3d66de1c7f/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=58f1c9445b5df8159db79b3d66de1c7f&amp;source=podcast&amp;photo%5fid=63723354" width="625" height="352" type="text/html" medium="video" duration="229" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/60445188/63723354/58f1c9445b5df8159db79b3d66de1c7f/standard/download-3-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/60445188/63723354/58f1c9445b5df8159db79b3d66de1c7f/standard/download-3-thumbnail.jpg/thumbnail.jpg"/>
            <category>toc analysis</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/60650858/63723357/ad02a8b0a600026bb7d184925f815961/audio/podcast/63723357-3-audio.mp3" type="audio/mp3" length="424470"/>
            <title>How to Load An Active Sequence in TOCView</title>
            <link>http://video.ysi.com/how-to-load-an-active-sequence-in</link>
            <description>&lt;p&gt;This video provides step-by-step instructions on how to load an active sequence&amp;nbsp;in TOCView.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-load-an-active-sequence-in"&gt;&lt;img src="http://video.ysi.com/60650858/63723357/ad02a8b0a600026bb7d184925f815961/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/63723357</guid>
            <pubDate>Mon, 31 Aug 2020 14:46:08 GMT</pubDate>
            <media:title>How to Load An Active Sequence in TOCView</media:title>
            <itunes:summary>This video provides step-by-step instructions on how to load an active sequencein TOCView.</itunes:summary>
            <itunes:subtitle>This video provides step-by-step instructions on how to load an active sequencein TOCView.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:11</itunes:duration>
            <media:description type="html">&lt;p&gt;This video provides step-by-step instructions on how to load an active sequence&amp;nbsp;in TOCView.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-load-an-active-sequence-in"&gt;&lt;img src="http://video.ysi.com/60650858/63723357/ad02a8b0a600026bb7d184925f815961/standard/download-3-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=ad02a8b0a600026bb7d184925f815961&amp;source=podcast&amp;photo%5fid=63723357" width="625" height="352" type="text/html" medium="video" duration="71" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/60650858/63723357/ad02a8b0a600026bb7d184925f815961/standard/download-3-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/60650858/63723357/ad02a8b0a600026bb7d184925f815961/standard/download-3-thumbnail.jpg/thumbnail.jpg"/>
            <category>how to load an active sequence</category>
            <category>toc analysis</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/60445025/63723358/a1b372fc0261fdce9237ab88088a84e2/audio/podcast/63723358-4-audio.mp3" type="audio/mp3" length="937306"/>
            <title>How to Properly Configure the 1080 TOC Combustion Analyzer</title>
            <link>http://video.ysi.com/how-to-properly-configure-the-1080</link>
            <description>&lt;p&gt;&lt;h2&gt;Configuring the 1080 TOC Combustion Analyzer&amp;nbsp;&amp;nbsp;&lt;/h2&gt;&lt;p&gt;When an instrument is shipped&amp;nbsp; from the factory, it is generally placed in 'Sipper Configuration.' Since the instrument is most likely attached to the 1088 AutoSampler, we must configure the Software and instruments.&amp;nbsp;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-properly-configure-the-1080"&gt;&lt;img src="http://video.ysi.com/60445025/63723358/a1b372fc0261fdce9237ab88088a84e2/standard/download-4-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/63723358</guid>
            <pubDate>Mon, 31 Aug 2020 14:44:22 GMT</pubDate>
            <media:title>How to Properly Configure the 1080 TOC Combustion Analyzer</media:title>
            <itunes:summary>Configuring the 1080 TOC Combustion AnalyzerWhen an instrument is shipped from the factory, it is generally placed in 'Sipper Configuration.' Since the instrument is most likely attached to the 1088 AutoSampler, we must configure the Software and instruments.</itunes:summary>
            <itunes:subtitle>Configuring the 1080 TOC Combustion AnalyzerWhen an instrument is shipped from the factory, it is generally placed in 'Sipper Configuration.' Since the instrument is most likely attached to the 1088 AutoSampler, we must configure the Software and...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>02:36</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;h2&gt;Configuring the 1080 TOC Combustion Analyzer&amp;nbsp;&amp;nbsp;&lt;/h2&gt;&lt;p&gt;When an instrument is shipped&amp;nbsp; from the factory, it is generally placed in 'Sipper Configuration.' Since the instrument is most likely attached to the 1088 AutoSampler, we must configure the Software and instruments.&amp;nbsp;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-properly-configure-the-1080"&gt;&lt;img src="http://video.ysi.com/60445025/63723358/a1b372fc0261fdce9237ab88088a84e2/standard/download-4-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=a1b372fc0261fdce9237ab88088a84e2&amp;source=podcast&amp;photo%5fid=63723358" width="625" height="352" type="text/html" medium="video" duration="156" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/60445025/63723358/a1b372fc0261fdce9237ab88088a84e2/standard/download-4-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/60445025/63723358/a1b372fc0261fdce9237ab88088a84e2/standard/download-4-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/60445187/63723463/2305ab721192956eac0d2f5236cc9e41/audio/podcast/63723463-2-audio.mp3" type="audio/mp3" length="8335810"/>
            <title>How to Install the 1080 TOC Analyzer with a 1088 Rotary AutoSampler</title>
            <link>http://video.ysi.com/how-to-install-the-1080-toc</link>
            <description>&lt;p&gt;This video provides step-by-step instructions on how to properly&amp;nbsp;install the 1080 TOC Analyzer and a 1088 Rotary AutoSampler.&amp;nbsp;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-install-the-1080-toc"&gt;&lt;img src="http://video.ysi.com/60445187/63723463/2305ab721192956eac0d2f5236cc9e41/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/63723463</guid>
            <pubDate>Mon, 31 Aug 2020 14:41:25 GMT</pubDate>
            <media:title>How to Install the 1080 TOC Analyzer with a 1088 Rotary AutoSampler</media:title>
            <itunes:summary>This video provides step-by-step instructions on how to properlyinstall the 1080 TOC Analyzer and a 1088 Rotary AutoSampler.</itunes:summary>
            <itunes:subtitle>This video provides step-by-step instructions on how to properlyinstall the 1080 TOC Analyzer and a 1088 Rotary AutoSampler.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>23:09</itunes:duration>
            <media:description type="html">&lt;p&gt;This video provides step-by-step instructions on how to properly&amp;nbsp;install the 1080 TOC Analyzer and a 1088 Rotary AutoSampler.&amp;nbsp;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-install-the-1080-toc"&gt;&lt;img src="http://video.ysi.com/60445187/63723463/2305ab721192956eac0d2f5236cc9e41/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=2305ab721192956eac0d2f5236cc9e41&amp;source=podcast&amp;photo%5fid=63723463" width="625" height="352" type="text/html" medium="video" duration="1389" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/60445187/63723463/2305ab721192956eac0d2f5236cc9e41/standard/download-2-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/60445187/63723463/2305ab721192956eac0d2f5236cc9e41/standard/download-2-thumbnail.jpg/thumbnail.jpg"/>
            <category>how to install a 1080 toc analyzer</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/60445190/63723323/d234b45f72fd2db947d8be5e193eb574/audio/podcast/63723323-2-audio.mp3" type="audio/mp3" length="1065828"/>
            <title>How To Polish an FS3700 Electrode</title>
            <link>http://video.ysi.com/how-to-polish-an-fs3700-electrode</link>
            <description>&lt;p&gt;Learn how to properly polish electrodes on the &lt;a href="https://www.oico.com/fs3700"&gt;FS3700&lt;/a&gt; to ensure complete accuracy and efficiency.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-polish-an-fs3700-electrode"&gt;&lt;img src="http://video.ysi.com/60445190/63723323/d234b45f72fd2db947d8be5e193eb574/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/63723323</guid>
            <pubDate>Thu, 20 Aug 2020 08:22:59 GMT</pubDate>
            <media:title>How To Polish an FS3700 Electrode</media:title>
            <itunes:summary>Learn how to properly polish electrodes on the FS3700 to ensure complete accuracy and efficiency.</itunes:summary>
            <itunes:subtitle>Learn how to properly polish electrodes on the FS3700 to ensure complete accuracy and efficiency.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>02:58</itunes:duration>
            <media:description type="html">&lt;p&gt;Learn how to properly polish electrodes on the &lt;a href="https://www.oico.com/fs3700"&gt;FS3700&lt;/a&gt; to ensure complete accuracy and efficiency.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-polish-an-fs3700-electrode"&gt;&lt;img src="http://video.ysi.com/60445190/63723323/d234b45f72fd2db947d8be5e193eb574/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=d234b45f72fd2db947d8be5e193eb574&amp;source=podcast&amp;photo%5fid=63723323" width="625" height="352" type="text/html" medium="video" duration="178" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/60445190/63723323/d234b45f72fd2db947d8be5e193eb574/standard/download-2-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/60445190/63723323/d234b45f72fd2db947d8be5e193eb574/standard/download-2-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/60650859/63723326/cfc6aa2598c32eb42888a4f751a3cb50/audio/podcast/63723326-2-audio.mp3" type="audio/mp3" length="629009"/>
            <title>How to Program the FS3700 Pump</title>
            <link>http://video.ysi.com/how-to-program-the-fs3700-pump</link>
            <description>&lt;p&gt;Learn how to properly set the speed and direction of the &lt;a href="https://www.oico.com/fs3700"&gt;FS3700&lt;/a&gt; pump.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-program-the-fs3700-pump"&gt;&lt;img src="http://video.ysi.com/60650859/63723326/cfc6aa2598c32eb42888a4f751a3cb50/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/63723326</guid>
            <pubDate>Thu, 20 Aug 2020 08:11:59 GMT</pubDate>
            <media:title>How to Program the FS3700 Pump</media:title>
            <itunes:summary>Learn how to properly set the speed and direction of the FS3700 pump.</itunes:summary>
            <itunes:subtitle>Learn how to properly set the speed and direction of the FS3700 pump.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:45</itunes:duration>
            <media:description type="html">&lt;p&gt;Learn how to properly set the speed and direction of the &lt;a href="https://www.oico.com/fs3700"&gt;FS3700&lt;/a&gt; pump.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/how-to-program-the-fs3700-pump"&gt;&lt;img src="http://video.ysi.com/60650859/63723326/cfc6aa2598c32eb42888a4f751a3cb50/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=cfc6aa2598c32eb42888a4f751a3cb50&amp;source=podcast&amp;photo%5fid=63723326" width="625" height="352" type="text/html" medium="video" duration="105" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/60650859/63723326/cfc6aa2598c32eb42888a4f751a3cb50/standard/download-2-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/60650859/63723326/cfc6aa2598c32eb42888a4f751a3cb50/standard/download-2-thumbnail.jpg/thumbnail.jpg"/>
            <category>automated chemistry analysis</category>
            <category>fs3700</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/60445026/63723481/358960e21e4cdde1e901dd543848718c/audio/podcast/63723481-2-audio.mp3" type="audio/mp3" length="1913920"/>
            <title>1080 TOC Analyzer | How to Pack a Combustion Tube</title>
            <link>http://video.ysi.com/1080-toc-analyzer-how-to-pack-a</link>
            <description>&lt;p&gt;This video provides step-by-step instructions on how to properly pack a combustion tube for TOC analysis.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/1080-toc-analyzer-how-to-pack-a"&gt;&lt;img src="http://video.ysi.com/60445026/63723481/358960e21e4cdde1e901dd543848718c/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/63723481</guid>
            <pubDate>Wed, 29 Jul 2020 18:20:07 GMT</pubDate>
            <media:title>1080 TOC Analyzer | How to Pack a Combustion Tube</media:title>
            <itunes:summary>This video provides step-by-step instructions on how to properly pack a combustion tube for TOC analysis.</itunes:summary>
            <itunes:subtitle>This video provides step-by-step instructions on how to properly pack a combustion tube for TOC analysis.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>05:19</itunes:duration>
            <media:description type="html">&lt;p&gt;This video provides step-by-step instructions on how to properly pack a combustion tube for TOC analysis.&amp;nbsp;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/1080-toc-analyzer-how-to-pack-a"&gt;&lt;img src="http://video.ysi.com/60445026/63723481/358960e21e4cdde1e901dd543848718c/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=358960e21e4cdde1e901dd543848718c&amp;source=podcast&amp;photo%5fid=63723481" width="625" height="352" type="text/html" medium="video" duration="319" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/60445026/63723481/358960e21e4cdde1e901dd543848718c/standard/download-2-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/60445026/63723481/358960e21e4cdde1e901dd543848718c/standard/download-2-thumbnail.jpg/thumbnail.jpg"/>
            <category>how to pack a combustion tube</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/12732911/37214227/bbdd926a838f373e38238182ed8d6507/audio/podcast/37214227-2-audio.mp3" type="audio/mp3" length="1436672"/>
            <title>Titroline 7000 Titrator Set Up</title>
            <link>http://video.ysi.com/titroline-7000-titrator-set-up</link>
            <description>&lt;p&gt;Product Specialist Vicky Kulczak demonstrates the set up of the &lt;a href="https://www.ysi.com/TitroLine7000"&gt;Titroline 7000 titrator&lt;/a&gt;.&lt;br&gt;&lt;p&gt;This video is ideal if you&amp;nbsp;have
recently purchased a TitroLine 7000 unit from us, or maybe you're thinking
about doing so. Either way, we go through all the steps of setting up
the hardware from A to Z and show you how simple it is. There are three main
components of the system, the first one being the TitroLine 7000 base unit. This is essentially the brain of the system, and all of the accessories will come along with it. The second part is the exchangeable
burette which is the slide-on/slide-off modular burette option that we
offer, and all the tubing comes along with that. The third component is the
magnetic stirrer. &lt;/p&gt;&lt;p&gt;This simple, how-to video will have you up an running in minutes.&lt;/p&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/titroline-7000-titrator-set-up"&gt;&lt;img src="http://video.ysi.com/12732911/37214227/bbdd926a838f373e38238182ed8d6507/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/37214227</guid>
            <pubDate>Thu, 08 Nov 2018 15:00:25 GMT</pubDate>
            <media:title>Titroline 7000 Titrator Set Up</media:title>
            <itunes:summary>Product Specialist Vicky Kulczak demonstrates the set up of the Titroline 7000 titrator.This video is ideal if youhave
recently purchased a TitroLine 7000 unit from us, or maybe you're thinking
about doing so. Either way, we go through all the steps of setting up
the hardware from A to Z and show you how simple it is. There are three main
components of the system, the first one being the TitroLine 7000 base unit. This is essentially the brain of the system, and all of the accessories will come along with it. The second part is the exchangeable
burette which is the slide-on/slide-off modular burette option that we
offer, and all the tubing comes along with that. The third component is the
magnetic stirrer. This simple, how-to video will have you up an running in minutes.</itunes:summary>
            <itunes:subtitle>Product Specialist Vicky Kulczak demonstrates the set up of the Titroline 7000 titrator.This video is ideal if youhave
recently purchased a TitroLine 7000 unit from us, or maybe you're thinking
about doing so. Either way, we go through all the...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>03:59</itunes:duration>
            <media:description type="html">&lt;p&gt;Product Specialist Vicky Kulczak demonstrates the set up of the &lt;a href="https://www.ysi.com/TitroLine7000"&gt;Titroline 7000 titrator&lt;/a&gt;.&lt;br&gt;&lt;p&gt;This video is ideal if you&amp;nbsp;have
recently purchased a TitroLine 7000 unit from us, or maybe you're thinking
about doing so. Either way, we go through all the steps of setting up
the hardware from A to Z and show you how simple it is. There are three main
components of the system, the first one being the TitroLine 7000 base unit. This is essentially the brain of the system, and all of the accessories will come along with it. The second part is the exchangeable
burette which is the slide-on/slide-off modular burette option that we
offer, and all the tubing comes along with that. The third component is the
magnetic stirrer. &lt;/p&gt;&lt;p&gt;This simple, how-to video will have you up an running in minutes.&lt;/p&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/titroline-7000-titrator-set-up"&gt;&lt;img src="http://video.ysi.com/12732911/37214227/bbdd926a838f373e38238182ed8d6507/standard/download-2-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=bbdd926a838f373e38238182ed8d6507&amp;source=podcast&amp;photo%5fid=37214227" width="625" height="352" type="text/html" medium="video" duration="239" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/12732911/37214227/bbdd926a838f373e38238182ed8d6507/standard/download-2-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/12732911/37214227/bbdd926a838f373e38238182ed8d6507/standard/download-2-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476794/20865419/2c9b285b212d26193e83ec6cdbabb7d9/audio/podcast/20865419-1-audio.mp3" type="audio/mp3" length="3183748"/>
            <title>Water Quality Sonde Biofouling Info</title>
            <link>http://video.ysi.com/water-quality-sonde-biofouling-info</link>
            <description>&lt;p&gt;The Art of Anti-Fouling | Join YSI Applications Engineer Curtis Butler as he discusses best practices for protecting your sonde from biofouling during long-term deployments&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/water-quality-sonde-biofouling-info"&gt;&lt;img src="http://video.ysi.com/19476794/20865419/2c9b285b212d26193e83ec6cdbabb7d9/standard/download-1-thumbnail.jpg" width="270" height="480"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20865419</guid>
            <pubDate>Sun, 25 Jun 2017 19:00:00 GMT</pubDate>
            <media:title>Water Quality Sonde Biofouling Info</media:title>
            <itunes:summary>The Art of Anti-Fouling | Join YSI Applications Engineer Curtis Butler as he discusses best practices for protecting your sonde from biofouling during long-term deployments</itunes:summary>
            <itunes:subtitle>The Art of Anti-Fouling | Join YSI Applications Engineer Curtis Butler as he discusses best practices for protecting your sonde from biofouling during long-term deployments</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>08:51</itunes:duration>
            <media:description type="html">&lt;p&gt;The Art of Anti-Fouling | Join YSI Applications Engineer Curtis Butler as he discusses best practices for protecting your sonde from biofouling during long-term deployments&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/water-quality-sonde-biofouling-info"&gt;&lt;img src="http://video.ysi.com/19476794/20865419/2c9b285b212d26193e83ec6cdbabb7d9/standard/download-1-thumbnail.jpg" width="270" height="480"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=2c9b285b212d26193e83ec6cdbabb7d9&amp;source=podcast&amp;photo%5fid=20865419" width="625" height="1109" type="text/html" medium="video" duration="531" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476794/20865419/2c9b285b212d26193e83ec6cdbabb7d9/standard/download-1-thumbnail.jpg" width="270" height="480"/>
            <itunes:image href="http://video.ysi.com/19476794/20865419/2c9b285b212d26193e83ec6cdbabb7d9/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476792/20722452/6f838597a40a45c4eb08f14990234704/audio/podcast/20722452-1-audio.mp3" type="audio/mp3" length="3407141"/>
            <title>YSI ProDSS Water Quality Instrument Ordering Guide</title>
            <link>http://video.ysi.com/ysi-prodss-water-quality-instrument</link>
            <description>&lt;p&gt;There are many options when ordering a ProDSS handheld multiparameter water quality system. The handheld is available with or without a GPS sensor. Several cable options are available and there are many ProDSS smart sensors to choose from. This video is included in our ProDSS On-Demand Training Program. Find out more at &lt;a href="https://www.ysi.com/ProDSS-training"&gt;https://www.ysi.com/ProDSS-training&lt;/a&gt;.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-prodss-water-quality-instrument"&gt;&lt;img src="http://video.ysi.com/19476792/20722452/6f838597a40a45c4eb08f14990234704/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20722452</guid>
            <pubDate>Thu, 09 Mar 2017 19:00:00 GMT</pubDate>
            <media:title>YSI ProDSS Water Quality Instrument Ordering Guide</media:title>
            <itunes:summary>There are many options when ordering a ProDSS handheld multiparameter water quality system. The handheld is available with or without a GPS sensor. Several cable options are available and there are many ProDSS smart sensors to choose from. This video is included in our ProDSS On-Demand Training Program. Find out more at https://www.ysi.com/ProDSS-training.</itunes:summary>
            <itunes:subtitle>There are many options when ordering a ProDSS handheld multiparameter water quality system. The handheld is available with or without a GPS sensor. Several cable options are available and there are many ProDSS smart sensors to choose from. This...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>09:28</itunes:duration>
            <media:description type="html">&lt;p&gt;There are many options when ordering a ProDSS handheld multiparameter water quality system. The handheld is available with or without a GPS sensor. Several cable options are available and there are many ProDSS smart sensors to choose from. This video is included in our ProDSS On-Demand Training Program. Find out more at &lt;a href="https://www.ysi.com/ProDSS-training"&gt;https://www.ysi.com/ProDSS-training&lt;/a&gt;.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-prodss-water-quality-instrument"&gt;&lt;img src="http://video.ysi.com/19476792/20722452/6f838597a40a45c4eb08f14990234704/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=6f838597a40a45c4eb08f14990234704&amp;source=podcast&amp;photo%5fid=20722452" width="625" height="469" type="text/html" medium="video" duration="568" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476792/20722452/6f838597a40a45c4eb08f14990234704/standard/download-1-thumbnail.jpg" width="600" height="450"/>
            <itunes:image href="http://video.ysi.com/19476792/20722452/6f838597a40a45c4eb08f14990234704/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476793/20723587/781357aac295fe254d5b53def88ad431/audio/podcast/20723587-1-audio.mp3" type="audio/mp3" length="4995647"/>
            <title>YSI IQ SensorNet 2020 XT | Menu Structure</title>
            <link>http://video.ysi.com/ysi-iq-sensornet-2020-xt-menu</link>
            <description>&lt;p&gt;See how easy it is to navigate the menu of the YSI IQ SensorNet 2020 XT (&lt;a href="https://www.ysi.com/IQSN2020"&gt;https://www.ysi.com/IQSN2020&lt;/a&gt;) continuous water quality monitoring and controller. This easy-to-use system allows you to monitor water quality in your water resource recovery facility continuously and accurately with the flexibility to add sensors as requirements change.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-iq-sensornet-2020-xt-menu"&gt;&lt;img src="http://video.ysi.com/19476793/20723587/781357aac295fe254d5b53def88ad431/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20723587</guid>
            <pubDate>Tue, 13 Oct 2015 19:00:00 GMT</pubDate>
            <media:title>YSI IQ SensorNet 2020 XT | Menu Structure</media:title>
            <itunes:summary>See how easy it is to navigate the menu of the YSI IQ SensorNet 2020 XT (https://www.ysi.com/IQSN2020) continuous water quality monitoring and controller. This easy-to-use system allows you to monitor water quality in your water resource recovery facility continuously and accurately with the flexibility to add sensors as requirements change.</itunes:summary>
            <itunes:subtitle>See how easy it is to navigate the menu of the YSI IQ SensorNet 2020 XT (https://www.ysi.com/IQSN2020) continuous water quality monitoring and controller. This easy-to-use system allows you to monitor water quality in your water resource recovery...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>13:52</itunes:duration>
            <media:description type="html">&lt;p&gt;See how easy it is to navigate the menu of the YSI IQ SensorNet 2020 XT (&lt;a href="https://www.ysi.com/IQSN2020"&gt;https://www.ysi.com/IQSN2020&lt;/a&gt;) continuous water quality monitoring and controller. This easy-to-use system allows you to monitor water quality in your water resource recovery facility continuously and accurately with the flexibility to add sensors as requirements change.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-iq-sensornet-2020-xt-menu"&gt;&lt;img src="http://video.ysi.com/19476793/20723587/781357aac295fe254d5b53def88ad431/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=781357aac295fe254d5b53def88ad431&amp;source=podcast&amp;photo%5fid=20723587" width="625" height="469" type="text/html" medium="video" duration="832" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476793/20723587/781357aac295fe254d5b53def88ad431/standard/download-1-thumbnail.jpg" width="600" height="450"/>
            <itunes:image href="http://video.ysi.com/19476793/20723587/781357aac295fe254d5b53def88ad431/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
            <category>IQ SensorNet</category>
            <category>wastewater</category>
            <category>water quality monitoring</category>
            <category>water resource recovery facility</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476793/20723575/043c3746a338a6c8cb3a992bf579983c/audio/podcast/20723575-1-audio.mp3" type="audio/mp3" length="1036996"/>
            <title>YSI IQ SensorNet P700 Orthophosphate Analyzer | Overview</title>
            <link>http://video.ysi.com/ysi-iq-sensornet-p700</link>
            <description>&lt;p&gt;Learn more about the IQ SensorNet P700 orthophosphate analyzer (&lt;a href="https://www.ysi.com/PO4"&gt;https://www.ysi.com/PO4&lt;/a&gt;) and how it can help monitor your biological phosphorus removal and control chemical dosing. The P700 measures the amount of orthophosphate throughout the wastewater treatment process - from primary settling to the biological tanks and effluent.
&lt;p&gt;The analyzer provides continuous data to help improve operational efficiency, lower operation costs as well as verification of phosphate elimination in order to meet permit requirements. A wide measurement range, low chemical use and built-in auto-calibration make the P700 ideal for continuous phosphorus monitoring.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-iq-sensornet-p700"&gt;&lt;img src="http://video.ysi.com/19476793/20723575/043c3746a338a6c8cb3a992bf579983c/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20723575</guid>
            <pubDate>Tue, 13 Oct 2015 19:00:00 GMT</pubDate>
            <media:title>YSI IQ SensorNet P700 Orthophosphate Analyzer | Overview</media:title>
            <itunes:summary>Learn more about the IQ SensorNet P700 orthophosphate analyzer (https://www.ysi.com/PO4) and how it can help monitor your biological phosphorus removal and control chemical dosing. The P700 measures the amount of orthophosphate throughout the wastewater treatment process - from primary settling to the biological tanks and effluent.
The analyzer provides continuous data to help improve operational efficiency, lower operation costs as well as verification of phosphate elimination in order to meet permit requirements. A wide measurement range, low chemical use and built-in auto-calibration make the P700 ideal for continuous phosphorus monitoring.</itunes:summary>
            <itunes:subtitle>Learn more about the IQ SensorNet P700 orthophosphate analyzer (https://www.ysi.com/PO4) and how it can help monitor your biological phosphorus removal and control chemical dosing. The P700 measures the amount of orthophosphate throughout the...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>02:53</itunes:duration>
            <media:description type="html">&lt;p&gt;Learn more about the IQ SensorNet P700 orthophosphate analyzer (&lt;a href="https://www.ysi.com/PO4"&gt;https://www.ysi.com/PO4&lt;/a&gt;) and how it can help monitor your biological phosphorus removal and control chemical dosing. The P700 measures the amount of orthophosphate throughout the wastewater treatment process - from primary settling to the biological tanks and effluent.
&lt;p&gt;The analyzer provides continuous data to help improve operational efficiency, lower operation costs as well as verification of phosphate elimination in order to meet permit requirements. A wide measurement range, low chemical use and built-in auto-calibration make the P700 ideal for continuous phosphorus monitoring.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-iq-sensornet-p700"&gt;&lt;img src="http://video.ysi.com/19476793/20723575/043c3746a338a6c8cb3a992bf579983c/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=043c3746a338a6c8cb3a992bf579983c&amp;source=podcast&amp;photo%5fid=20723575" width="625" height="469" type="text/html" medium="video" duration="173" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476793/20723575/043c3746a338a6c8cb3a992bf579983c/standard/download-1-thumbnail.jpg" width="600" height="450"/>
            <itunes:image href="http://video.ysi.com/19476793/20723575/043c3746a338a6c8cb3a992bf579983c/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
            <category>IQ SensorNet</category>
            <category>P700 orthophosphate</category>
            <category>YSI IQ SensorNet</category>
            <category>phosphorus</category>
            <category>phosphorus in wastewater</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476793/20723567/1b9d2e595d0305ef2850d25ae6cb0fb4/audio/podcast/20723567-1-audio.mp3" type="audio/mp3" length="3074237"/>
            <title>YSI Ammonia Ion Selective Electrode (ISE) | Calibration</title>
            <link>http://video.ysi.com/ysi-ammonia-ion-selective-electrode</link>
            <description>&lt;p&gt;The measurement of ammonia is critically important in applications such as wastewater, where treatment plants are required to provide laboratory measurement of ammonia concentration. The ammonia ion selective electrode (ISE) is an EPA approved method of determining ammonia concentration for compliance reporting.&lt;br&gt;&lt;br&gt;&lt;img alt="" src="https://www.ysi.com/parameters/ammonia"&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-ammonia-ion-selective-electrode"&gt;&lt;img src="http://video.ysi.com/19476793/20723567/1b9d2e595d0305ef2850d25ae6cb0fb4/standard/download-1-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20723567</guid>
            <pubDate>Tue, 13 Oct 2015 19:00:00 GMT</pubDate>
            <media:title>YSI Ammonia Ion Selective Electrode (ISE) | Calibration</media:title>
            <itunes:summary>The measurement of ammonia is critically important in applications such as wastewater, where treatment plants are required to provide laboratory measurement of ammonia concentration. The ammonia ion selective electrode (ISE) is an EPA approved method of determining ammonia concentration for compliance reporting.</itunes:summary>
            <itunes:subtitle>The measurement of ammonia is critically important in applications such as wastewater, where treatment plants are required to provide laboratory measurement of ammonia concentration. The ammonia ion selective electrode (ISE) is an EPA approved...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>08:32</itunes:duration>
            <media:description type="html">&lt;p&gt;The measurement of ammonia is critically important in applications such as wastewater, where treatment plants are required to provide laboratory measurement of ammonia concentration. The ammonia ion selective electrode (ISE) is an EPA approved method of determining ammonia concentration for compliance reporting.&lt;br&gt;&lt;br&gt;&lt;img alt="" src="https://www.ysi.com/parameters/ammonia"&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-ammonia-ion-selective-electrode"&gt;&lt;img src="http://video.ysi.com/19476793/20723567/1b9d2e595d0305ef2850d25ae6cb0fb4/standard/download-1-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=1b9d2e595d0305ef2850d25ae6cb0fb4&amp;source=podcast&amp;photo%5fid=20723567" width="625" height="352" type="text/html" medium="video" duration="512" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476793/20723567/1b9d2e595d0305ef2850d25ae6cb0fb4/standard/download-1-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/19476793/20723567/1b9d2e595d0305ef2850d25ae6cb0fb4/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
            <category>Ion Selective Electrode</category>
            <category>YSI</category>
            <category>ammonia</category>
            <category>ammonia electrode</category>
            <category>laboratory meter</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476789/20723116/cab92a13e6f9686894491cf2b110c081/audio/podcast/20723116-1-audio.mp3" type="audio/mp3" length="979540"/>
            <title>YSI IQ SensorNet P700 Orthophosphate Analyzer | Pump and Valve Assembly Check</title>
            <link>http://video.ysi.com/ysi-iq-sensornet-p700-1</link>
            <description>&lt;p&gt;Learn how to check the pump and valve assembly on the YSI IQ SensorNet P700 Orthophosphate Analyzer (&lt;a href="https://www.ysi.com/PO4"&gt;https://www.ysi.com/PO4&lt;/a&gt;) with these 3 easy steps.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-iq-sensornet-p700-1"&gt;&lt;img src="http://video.ysi.com/19476789/20723116/cab92a13e6f9686894491cf2b110c081/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20723116</guid>
            <pubDate>Tue, 13 Oct 2015 19:00:00 GMT</pubDate>
            <media:title>YSI IQ SensorNet P700 Orthophosphate Analyzer | Pump and Valve Assembly Check</media:title>
            <itunes:summary>Learn how to check the pump and valve assembly on the YSI IQ SensorNet P700 Orthophosphate Analyzer (https://www.ysi.com/PO4) with these 3 easy steps.</itunes:summary>
            <itunes:subtitle>Learn how to check the pump and valve assembly on the YSI IQ SensorNet P700 Orthophosphate Analyzer (https://www.ysi.com/PO4) with these 3 easy steps.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>02:43</itunes:duration>
            <media:description type="html">&lt;p&gt;Learn how to check the pump and valve assembly on the YSI IQ SensorNet P700 Orthophosphate Analyzer (&lt;a href="https://www.ysi.com/PO4"&gt;https://www.ysi.com/PO4&lt;/a&gt;) with these 3 easy steps.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-iq-sensornet-p700-1"&gt;&lt;img src="http://video.ysi.com/19476789/20723116/cab92a13e6f9686894491cf2b110c081/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=cab92a13e6f9686894491cf2b110c081&amp;source=podcast&amp;photo%5fid=20723116" width="625" height="469" type="text/html" medium="video" duration="163" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476789/20723116/cab92a13e6f9686894491cf2b110c081/standard/download-1-thumbnail.jpg" width="600" height="450"/>
            <itunes:image href="http://video.ysi.com/19476789/20723116/cab92a13e6f9686894491cf2b110c081/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
            <category>IQ SensorNet</category>
            <category>YSI IQ SensorNet</category>
            <category>YSI P700</category>
            <category>orthophosphate</category>
            <category>phosphorus in wastewater</category>
            <category>wastewater</category>
            <category>water resource recovery facility</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476793/20723108/63207bd409b45c46ad477e1bf1269fd7/audio/podcast/20723108-1-audio.mp3" type="audio/mp3" length="1341412"/>
            <title>YSI IQ SensorNet P700 Orthophosphate Analyzer | Set Up</title>
            <link>http://video.ysi.com/ysi-iq-sensornet-p700-2</link>
            <description>&lt;p&gt;Learn more about the IQ SensorNet P700 orthophosphate analyzer (&lt;a href="https://www.ysi.com/PO4"&gt;https://www.ysi.com/PO4&lt;/a&gt;) and how it can help monitor your biological phosphorus removal and control chemical dosing. The P700 measures the amount of orthophosphate throughout the wastewater treatment process - from primary settling to the biological tanks and effluent.
&lt;p&gt;The analyzer provides continuous data to help improve operational efficiency, lower operation costs as well as verification of phosphate elimination in order to meet permit requirements. A wide measurement range, low chemical use and built-in auto-calibration make the P700 ideal for continuous phosphorus monitoring.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-iq-sensornet-p700-2"&gt;&lt;img src="http://video.ysi.com/19476793/20723108/63207bd409b45c46ad477e1bf1269fd7/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20723108</guid>
            <pubDate>Tue, 13 Oct 2015 19:00:00 GMT</pubDate>
            <media:title>YSI IQ SensorNet P700 Orthophosphate Analyzer | Set Up</media:title>
            <itunes:summary>Learn more about the IQ SensorNet P700 orthophosphate analyzer (https://www.ysi.com/PO4) and how it can help monitor your biological phosphorus removal and control chemical dosing. The P700 measures the amount of orthophosphate throughout the wastewater treatment process - from primary settling to the biological tanks and effluent.
The analyzer provides continuous data to help improve operational efficiency, lower operation costs as well as verification of phosphate elimination in order to meet permit requirements. A wide measurement range, low chemical use and built-in auto-calibration make the P700 ideal for continuous phosphorus monitoring.</itunes:summary>
            <itunes:subtitle>Learn more about the IQ SensorNet P700 orthophosphate analyzer (https://www.ysi.com/PO4) and how it can help monitor your biological phosphorus removal and control chemical dosing. The P700 measures the amount of orthophosphate throughout the...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>03:43</itunes:duration>
            <media:description type="html">&lt;p&gt;Learn more about the IQ SensorNet P700 orthophosphate analyzer (&lt;a href="https://www.ysi.com/PO4"&gt;https://www.ysi.com/PO4&lt;/a&gt;) and how it can help monitor your biological phosphorus removal and control chemical dosing. The P700 measures the amount of orthophosphate throughout the wastewater treatment process - from primary settling to the biological tanks and effluent.
&lt;p&gt;The analyzer provides continuous data to help improve operational efficiency, lower operation costs as well as verification of phosphate elimination in order to meet permit requirements. A wide measurement range, low chemical use and built-in auto-calibration make the P700 ideal for continuous phosphorus monitoring.&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-iq-sensornet-p700-2"&gt;&lt;img src="http://video.ysi.com/19476793/20723108/63207bd409b45c46ad477e1bf1269fd7/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=63207bd409b45c46ad477e1bf1269fd7&amp;source=podcast&amp;photo%5fid=20723108" width="625" height="469" type="text/html" medium="video" duration="223" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476793/20723108/63207bd409b45c46ad477e1bf1269fd7/standard/download-1-thumbnail.jpg" width="600" height="450"/>
            <itunes:image href="http://video.ysi.com/19476793/20723108/63207bd409b45c46ad477e1bf1269fd7/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
            <category>P700 orthophosphate</category>
            <category>YSI IQ SensorNet</category>
            <category>orthophosphate</category>
            <category>phosphorus in wastewater</category>
            <category>wastewater</category>
            <category>water resource recovery facility</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476792/20724873/41a60a770dc379c03c370a17dc1ad99f/audio/podcast/20724873-1-audio.mp3" type="audio/mp3" length="112108"/>
            <title>YSI IQ SensorNet VARiON ISE Cleaning</title>
            <link>http://video.ysi.com/ysi-iq-sensornet-varion-ise</link>
            <description>&lt;p&gt;Quick overview of the physical cleaning process of the YSI IQ SensorNet VARiON ISE sensor cleaning.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-iq-sensornet-varion-ise"&gt;&lt;img src="http://video.ysi.com/19476792/20724873/41a60a770dc379c03c370a17dc1ad99f/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20724873</guid>
            <pubDate>Sun, 05 Feb 2012 19:00:00 GMT</pubDate>
            <media:title>YSI IQ SensorNet VARiON ISE Cleaning</media:title>
            <itunes:summary>Quick overview of the physical cleaning process of the YSI IQ SensorNet VARiON ISE sensor cleaning.</itunes:summary>
            <itunes:subtitle>Quick overview of the physical cleaning process of the YSI IQ SensorNet VARiON ISE sensor cleaning.</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>00:19</itunes:duration>
            <media:description type="html">&lt;p&gt;Quick overview of the physical cleaning process of the YSI IQ SensorNet VARiON ISE sensor cleaning.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-iq-sensornet-varion-ise"&gt;&lt;img src="http://video.ysi.com/19476792/20724873/41a60a770dc379c03c370a17dc1ad99f/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=41a60a770dc379c03c370a17dc1ad99f&amp;source=podcast&amp;photo%5fid=20724873" width="625" height="469" type="text/html" medium="video" duration="19" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476792/20724873/41a60a770dc379c03c370a17dc1ad99f/standard/download-1-thumbnail.jpg" width="600" height="450"/>
            <itunes:image href="http://video.ysi.com/19476792/20724873/41a60a770dc379c03c370a17dc1ad99f/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
            <category>Cleaning</category>
            <category>IQ</category>
            <category>ISE</category>
            <category>SensorNet</category>
            <category>VARiON</category>
            <category>YSI</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476792/20724269/f998c93a7db0920dfb21725439c0842d/audio/podcast/20724269-1-audio.mp3" type="audio/mp3" length="158884"/>
            <title>YSI Pro20 Calibración Oxígeno Disuelto</title>
            <link>http://video.ysi.com/ysi-pro20-calibracion-oxigeno-disuelto-1</link>
            <description>&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-pro20-calibracion-oxigeno-disuelto-1"&gt;&lt;img src="http://video.ysi.com/19476792/20724269/f998c93a7db0920dfb21725439c0842d/standard/download-1-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20724269</guid>
            <pubDate>Mon, 25 Apr 2011 19:00:00 GMT</pubDate>
            <media:title>YSI Pro20 Calibración Oxígeno Disuelto</media:title>
            <itunes:summary></itunes:summary>
            <itunes:subtitle></itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>00:26</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-pro20-calibracion-oxigeno-disuelto-1"&gt;&lt;img src="http://video.ysi.com/19476792/20724269/f998c93a7db0920dfb21725439c0842d/standard/download-1-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=f998c93a7db0920dfb21725439c0842d&amp;source=podcast&amp;photo%5fid=20724269" width="625" height="352" type="text/html" medium="video" duration="26" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476792/20724269/f998c93a7db0920dfb21725439c0842d/standard/download-1-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/19476792/20724269/f998c93a7db0920dfb21725439c0842d/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
            <category>Calibracion</category>
            <category>Oxígeno Disuelto</category>
            <category>Pro20</category>
            <category>YSI</category>
            <category>YSI Professional Series</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476794/20724440/c939ed7560ecee2fd969ff29b936b6cd/audio/podcast/20724440-1-audio.mp3" type="audio/mp3" length="158884"/>
            <title>YSI Pro20 Dissolved Oxygen Meter Calibration</title>
            <link>http://video.ysi.com/ysi-pro20-dissolved-oxygen-meter-calibration-1</link>
            <description>&lt;p&gt;How to Calibrate a YSI Pro20 Dissolved Oxygen meter for the lab or field.  Learn more at &lt;a href="http://www.ysi.com/pro20"&gt;http://www.ysi.com/pro20&lt;/a&gt;. Calibrate you DO meter quickly and easily with the "Quick Cal" function.  DO meter calibration has never been easier!&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-pro20-dissolved-oxygen-meter-calibration-1"&gt;&lt;img src="http://video.ysi.com/19476794/20724440/c939ed7560ecee2fd969ff29b936b6cd/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20724440</guid>
            <pubDate>Wed, 29 Jul 2009 19:00:00 GMT</pubDate>
            <media:title>YSI Pro20 Dissolved Oxygen Meter Calibration</media:title>
            <itunes:summary>How to Calibrate a YSI Pro20 Dissolved Oxygen meter for the lab or field.  Learn more at http://www.ysi.com/pro20. Calibrate you DO meter quickly and easily with the "Quick Cal" function.  DO meter calibration has never been easier!</itunes:summary>
            <itunes:subtitle>How to Calibrate a YSI Pro20 Dissolved Oxygen meter for the lab or field.  Learn more at http://www.ysi.com/pro20. Calibrate you DO meter quickly and easily with the "Quick Cal" function.  DO meter calibration has never been easier!</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>00:26</itunes:duration>
            <media:description type="html">&lt;p&gt;How to Calibrate a YSI Pro20 Dissolved Oxygen meter for the lab or field.  Learn more at &lt;a href="http://www.ysi.com/pro20"&gt;http://www.ysi.com/pro20&lt;/a&gt;. Calibrate you DO meter quickly and easily with the "Quick Cal" function.  DO meter calibration has never been easier!&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-pro20-dissolved-oxygen-meter-calibration-1"&gt;&lt;img src="http://video.ysi.com/19476794/20724440/c939ed7560ecee2fd969ff29b936b6cd/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=c939ed7560ecee2fd969ff29b936b6cd&amp;source=podcast&amp;photo%5fid=20724440" width="625" height="469" type="text/html" medium="video" duration="26" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476794/20724440/c939ed7560ecee2fd969ff29b936b6cd/standard/download-1-thumbnail.jpg" width="600" height="450"/>
            <itunes:image href="http://video.ysi.com/19476794/20724440/c939ed7560ecee2fd969ff29b936b6cd/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
            <category>DO</category>
            <category>DO instrument</category>
            <category>DO meter</category>
            <category>DO meter calibration</category>
            <category>dissolved oxygen</category>
            <category>dissolved oxygen instrument</category>
            <category>dissolved oxygen meter</category>
            <category>dissolved oxygen meters</category>
            <category>how to calibrate a DO meter</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476794/20725040/63256f226358a617bce61bb64235014b/audio/podcast/20725040-1-audio.mp3" type="audio/mp3" length="648767"/>
            <title>YSI Pro20 Dissolved Oxygen Meter Initial Setup</title>
            <link>http://video.ysi.com/ysi-pro20-dissolved-oxygen-meter-initial-setup-1</link>
            <description>&lt;p&gt;A walkthrough of the initial set for the YSI Pro20 Dissolved Oxygen instrument.  Learn more at &lt;a href="http://www.ysi.com/pro20"&gt;http://www.ysi.com/pro20&lt;/a&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-pro20-dissolved-oxygen-meter-initial-setup-1"&gt;&lt;img src="http://video.ysi.com/19476794/20725040/63256f226358a617bce61bb64235014b/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20725040</guid>
            <pubDate>Mon, 18 May 2009 19:00:00 GMT</pubDate>
            <media:title>YSI Pro20 Dissolved Oxygen Meter Initial Setup</media:title>
            <itunes:summary>A walkthrough of the initial set for the YSI Pro20 Dissolved Oxygen instrument.  Learn more at http://www.ysi.com/pro20</itunes:summary>
            <itunes:subtitle>A walkthrough of the initial set for the YSI Pro20 Dissolved Oxygen instrument.  Learn more at http://www.ysi.com/pro20</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:48</itunes:duration>
            <media:description type="html">&lt;p&gt;A walkthrough of the initial set for the YSI Pro20 Dissolved Oxygen instrument.  Learn more at &lt;a href="http://www.ysi.com/pro20"&gt;http://www.ysi.com/pro20&lt;/a&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-pro20-dissolved-oxygen-meter-initial-setup-1"&gt;&lt;img src="http://video.ysi.com/19476794/20725040/63256f226358a617bce61bb64235014b/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=63256f226358a617bce61bb64235014b&amp;source=podcast&amp;photo%5fid=20725040" width="625" height="469" type="text/html" medium="video" duration="108" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476794/20725040/63256f226358a617bce61bb64235014b/standard/download-1-thumbnail.jpg" width="600" height="450"/>
            <itunes:image href="http://video.ysi.com/19476794/20725040/63256f226358a617bce61bb64235014b/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
            <category>DO</category>
            <category>DO instrument</category>
            <category>DO meter</category>
            <category>dissolved oxygen</category>
            <category>dissolved oxygen instrument</category>
            <category>dissolved oxygen meter</category>
            <category>dissolved oxygen meters</category>
            <category>handheld DO</category>
            <category>water quality</category>
            <category>water quality instrument</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476793/20724475/70153726898657916062a8942135ce1b/audio/podcast/20724475-1-audio.mp3" type="audio/mp3" length="649551"/>
            <title>YSI Pro20 Dissolved Oxygen Meter Sensor Installation</title>
            <link>http://video.ysi.com/ysi-pro20-dissolved-oxygen-meter-sensor-1</link>
            <description>&lt;p&gt;Learn how to install a YSI Pro20 DO meter sensor and membrane cap.  Learn more at &lt;a href="http://ysi.com/pro20"&gt;http://ysi.com/pro20&lt;/a&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-pro20-dissolved-oxygen-meter-sensor-1"&gt;&lt;img src="http://video.ysi.com/19476793/20724475/70153726898657916062a8942135ce1b/standard/download-1-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20724475</guid>
            <pubDate>Sun, 12 Apr 2009 19:00:00 GMT</pubDate>
            <media:title>YSI Pro20 Dissolved Oxygen Meter Sensor Installation</media:title>
            <itunes:summary>Learn how to install a YSI Pro20 DO meter sensor and membrane cap.  Learn more at http://ysi.com/pro20</itunes:summary>
            <itunes:subtitle>Learn how to install a YSI Pro20 DO meter sensor and membrane cap.  Learn more at http://ysi.com/pro20</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>01:48</itunes:duration>
            <media:description type="html">&lt;p&gt;Learn how to install a YSI Pro20 DO meter sensor and membrane cap.  Learn more at &lt;a href="http://ysi.com/pro20"&gt;http://ysi.com/pro20&lt;/a&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-pro20-dissolved-oxygen-meter-sensor-1"&gt;&lt;img src="http://video.ysi.com/19476793/20724475/70153726898657916062a8942135ce1b/standard/download-1-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=70153726898657916062a8942135ce1b&amp;source=podcast&amp;photo%5fid=20724475" width="625" height="352" type="text/html" medium="video" duration="108" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476793/20724475/70153726898657916062a8942135ce1b/standard/download-1-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/19476793/20724475/70153726898657916062a8942135ce1b/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
            <category>DO</category>
            <category>DO instrument</category>
            <category>DO meter</category>
            <category>dissolved oxygen</category>
            <category>dissolved oxygen instrument</category>
            <category>dissolved oxygen meter</category>
            <category>dissolved oxygen meters</category>
            <category>handheld DO</category>
            <category>water quality</category>
            <category>water quality instrument</category>
        </item>
    </channel>
</rss>