<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0" xmlns:media="http://search.yahoo.com/mrss/" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:itunes="http://www.itunes.com/dtds/podcast-1.0.dtd">
    <channel>
        <itunes:owner>
            <itunes:name>YSI Videos | ysi.com</itunes:name>
            <itunes:email>info@ysi.com</itunes:email>
        </itunes:owner>
        <title>YSI Videos | ysi.com</title>
        <link>https://video.ysi.com</link>
        <description></description>
        <language>en-us</language>
        <generator>Visualplatform</generator>
        <docs>http://blogs.law.harvard.edu/tech/rss</docs>
        <itunes:author>YSI Videos | ysi.com</itunes:author>
        <itunes:type>episodic</itunes:type>
        <itunes:explicit>no</itunes:explicit>
        <itunes:image href="https://video.ysi.com/files/rv1.4/sitelogo.gif"/>
        <image>
            <url>https://video.ysi.com/files/rv1.4/sitelogo.gif</url>
            <title>YSI Videos | ysi.com</title>
            <link>https://video.ysi.com</link>
        </image>
        <atom:link rel="self" href="https://video.ysi.com/rss/tag/multilab"/>
        <atom:link rel="next" href="https://video.ysi.com/rss/tag/multilab?tag=multilab&amp;p=2&amp;podcast%5fp=f&amp;https="/>
        <item>
            <enclosure url="http://video.ysi.com/64968570/131941043/0f8dba128920d505c2ac59ecdedf84dd/video_medium/bod-analysis-with-the-ysi-proobod-video.mp4?source=podcast" type="video/mp4" length="18796355"/>
            <title>BOD Analysis with the YSI ProOBOD Probe &amp; MultiLab Pro IDS: Setup,...</title>
            <link>http://video.ysi.com/bod-analysis-with-the-ysi-proobod</link>
            <description>&lt;p&gt;&lt;p&gt;In this video, we walk through Biological Oxygen Demand (BOD) analysis — a cornerstone test for environmental water testing and wastewater treatment monitoring. We cover what BOD measures, why the 5-day standard matters, and how to get up and running with the YSI ProOBOD probe on the MultiLab Pro IDS. You'll learn how to connect and configure both optical and polarographic BOD probes, update sensor cap coefficients, perform a calibration, take and store dissolved oxygen readings, run on-board OUR/SOUR tests, and export your data for documentation and sharing. By the end, you'll be ready to set up, calibrate, and measure with confidence.&lt;/p&gt;&lt;p&gt;Learn more about the YSI MultiLab® Pro IDS: &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/multilab"&gt;&lt;u&gt;https://www.ysi.com/multilab&lt;/u&gt;&lt;/a&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/bod-analysis-with-the-ysi-proobod"&gt;&lt;img src="http://video.ysi.com/64968570/131941043/0f8dba128920d505c2ac59ecdedf84dd/standard/download-24-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/131941043</guid>
            <pubDate>Fri, 18 Sep 2026 15:23:36 GMT</pubDate>
            <media:title>BOD Analysis with the YSI ProOBOD Probe &amp; MultiLab Pro IDS: Setup,...</media:title>
            <itunes:summary>In this video, we walk through Biological Oxygen Demand (BOD) analysis — a cornerstone test for environmental water testing and wastewater treatment monitoring. We cover what BOD measures, why the 5-day standard matters, and how to get up and running with the YSI ProOBOD probe on the MultiLab Pro IDS. You'll learn how to connect and configure both optical and polarographic BOD probes, update sensor cap coefficients, perform a calibration, take and store dissolved oxygen readings, run on-board OUR/SOUR tests, and export your data for documentation and sharing. By the end, you'll be ready to set up, calibrate, and measure with confidence.Learn more about the YSI MultiLab® Pro IDS: https://www.ysi.com/multilab</itunes:summary>
            <itunes:subtitle>In this video, we walk through Biological Oxygen Demand (BOD) analysis — a cornerstone test for environmental water testing and wastewater treatment monitoring. We cover what BOD measures, why the 5-day standard matters, and how to get up and...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>04:46</itunes:duration>
            <media:description type="html">&lt;p&gt;&lt;p&gt;In this video, we walk through Biological Oxygen Demand (BOD) analysis — a cornerstone test for environmental water testing and wastewater treatment monitoring. We cover what BOD measures, why the 5-day standard matters, and how to get up and running with the YSI ProOBOD probe on the MultiLab Pro IDS. You'll learn how to connect and configure both optical and polarographic BOD probes, update sensor cap coefficients, perform a calibration, take and store dissolved oxygen readings, run on-board OUR/SOUR tests, and export your data for documentation and sharing. By the end, you'll be ready to set up, calibrate, and measure with confidence.&lt;/p&gt;&lt;p&gt;Learn more about the YSI MultiLab® Pro IDS: &lt;a target="_blank" rel="noopener noreferrer nofollow" href="https://www.ysi.com/multilab"&gt;&lt;u&gt;https://www.ysi.com/multilab&lt;/u&gt;&lt;/a&gt;&lt;/p&gt;&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/bod-analysis-with-the-ysi-proobod"&gt;&lt;img src="http://video.ysi.com/64968570/131941043/0f8dba128920d505c2ac59ecdedf84dd/standard/download-24-thumbnail.jpg" width="600" height="338"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=0f8dba128920d505c2ac59ecdedf84dd&amp;source=podcast&amp;photo%5fid=131941043" width="625" height="352" type="text/html" medium="video" duration="286" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/64968570/131941043/0f8dba128920d505c2ac59ecdedf84dd/standard/download-24-thumbnail.jpg" width="600" height="338"/>
            <itunes:image href="http://video.ysi.com/64968570/131941043/0f8dba128920d505c2ac59ecdedf84dd/standard/download-24-thumbnail.jpg/thumbnail.jpg"/>
            <category>multilab</category>
        </item>
        <item>
            <enclosure url="http://video.ysi.com/19476794/20723532/f5f94833a75b34e1e3a7ef7fb7a5caec/video_medium/ysi-multilab-laboratory-meter-from-the-box-to-the-1-video.mp4?source=podcast" type="video/mp4" length="22526386"/>
            <title>YSI MultiLab Laboratory Meter | From the Box to the Lab</title>
            <link>http://video.ysi.com/ysi-multilab-laboratory-meter-from-the-box-to-the-1</link>
            <description>&lt;p&gt;The MultiLab instrument measures pH, ORP, conductivity, BOD and ion activity measurement. Connect digital Intelligent Digital Sensors (IDS) to the MultiLab 4010-3 (https://www.ysi.com/MultiLab-4010-3) for the measurement of pH, ORP, conductivity, and DO/BOD in any combination. Ion selective electrodes (ISE) can also be connected to the instrument. Find out all the other great features of the YSI MultiLab instrument in this video including the large, graphic display, plug-and-play connectivity, GLP traceability, USB connectivity to manage data, electrode stand, 3-year warranty and much more.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-multilab-laboratory-meter-from-the-box-to-the-1"&gt;&lt;img src="http://video.ysi.com/19476794/20723532/f5f94833a75b34e1e3a7ef7fb7a5caec/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</description>
            <guid>http://video.ysi.com/photo/20723532</guid>
            <pubDate>Tue, 13 Oct 2015 19:00:00 GMT</pubDate>
            <media:title>YSI MultiLab Laboratory Meter | From the Box to the Lab</media:title>
            <itunes:summary>The MultiLab instrument measures pH, ORP, conductivity, BOD and ion activity measurement. Connect digital Intelligent Digital Sensors (IDS) to the MultiLab 4010-3 (https://www.ysi.com/MultiLab-4010-3) for the measurement of pH, ORP, conductivity, and DO/BOD in any combination. Ion selective electrodes (ISE) can also be connected to the instrument. Find out all the other great features of the YSI MultiLab instrument in this video including the large, graphic display, plug-and-play connectivity, GLP traceability, USB connectivity to manage data, electrode stand, 3-year warranty and much more.</itunes:summary>
            <itunes:subtitle>The MultiLab instrument measures pH, ORP, conductivity, BOD and ion activity measurement. Connect digital Intelligent Digital Sensors (IDS) to the MultiLab 4010-3 (https://www.ysi.com/MultiLab-4010-3) for the measurement of pH, ORP, conductivity,...</itunes:subtitle>
            <itunes:author>YSI Videos | ysi.com</itunes:author>
            <itunes:duration>06:11</itunes:duration>
            <media:description type="html">&lt;p&gt;The MultiLab instrument measures pH, ORP, conductivity, BOD and ion activity measurement. Connect digital Intelligent Digital Sensors (IDS) to the MultiLab 4010-3 (https://www.ysi.com/MultiLab-4010-3) for the measurement of pH, ORP, conductivity, and DO/BOD in any combination. Ion selective electrodes (ISE) can also be connected to the instrument. Find out all the other great features of the YSI MultiLab instrument in this video including the large, graphic display, plug-and-play connectivity, GLP traceability, USB connectivity to manage data, electrode stand, 3-year warranty and much more.&lt;/p&gt;&lt;p&gt;&lt;a href="http://video.ysi.com/ysi-multilab-laboratory-meter-from-the-box-to-the-1"&gt;&lt;img src="http://video.ysi.com/19476794/20723532/f5f94833a75b34e1e3a7ef7fb7a5caec/standard/download-1-thumbnail.jpg" width="600" height="450"/&gt;&lt;/a&gt;&lt;/p&gt;</media:description>
            <media:content url="https://video.ysi.com/v.ihtml/player.html?token=f5f94833a75b34e1e3a7ef7fb7a5caec&amp;source=podcast&amp;photo%5fid=20723532" width="625" height="469" type="text/html" medium="video" duration="371" isDefault="true" expression="full"/>
            <media:thumbnail url="http://video.ysi.com/19476794/20723532/f5f94833a75b34e1e3a7ef7fb7a5caec/standard/download-1-thumbnail.jpg" width="600" height="450"/>
            <itunes:image href="http://video.ysi.com/19476794/20723532/f5f94833a75b34e1e3a7ef7fb7a5caec/standard/download-1-thumbnail.jpg/thumbnail.jpg"/>
            <category>MultiLab</category>
            <category>YSI</category>
            <category>YSI multilab</category>
            <category>laboraotry instrument</category>
            <category>laboratory meter</category>
            <category>pH lab meter</category>
        </item>
    </channel>
</rss>
